ASTM D890-2012(2016) Standard Test Method for Water in Liquid Pine Chemicals《液体松脂中水含量的标准试验方法》.pdf
《ASTM D890-2012(2016) Standard Test Method for Water in Liquid Pine Chemicals《液体松脂中水含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D890-2012(2016) Standard Test Method for Water in Liquid Pine Chemicals《液体松脂中水含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D890 12 (Reapproved 2016)Standard Test Method forWater in Liquid Pine Chemicals1This standard is issued under the fixed designation D890; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the quantitative determinationof dissolved or occluded water present in any proportion inliquid pine chemicals, s
3、uch as turpentine, pinene, dipentene,pine oil, tall oil, and tall oil fatty acids. Three methods ofmoisture testing are included. The Karl Fisher titration methodis the preferred method for testing tall oil, Test Methods D803.1.1.1 The Karl Fischer Titration method is based on thereaction between wa
4、ter and a complex reagent2consisting ofiodine, sulfur dioxide, pyridine, and methanol, whereby theiodine is converted to a colorless compound. The appearanceof a persistent iodine color in the reaction mixture indicates thecomplete removal of free water by reaction with the reagent,and the endpoint
5、may be measured colorimetrically. Automatictitrators find this endpoint by the restoration of a currentstrength when the resistance provided by the presence of wateris eliminated. Amperometric automatic titrators find this end-point by detecting the current flow that occurs once water iseliminated.1
6、.1.2 The coulometric titration method determines watercontent by electronic integration of a current sufficient togenerate the precise amount of iodine from the required reagentto react with the water in the sample.1.1.3 The azeotropic method utilizes the relatively lowboiling point of water, as com
7、pared with other sampleconstituents, in a toluene or xylene matrix so that water iscollected in a trap and measured.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafe
8、ty concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D803 Test Methods for Testing Ta
9、ll OilD1364 Test Method for Water in Volatile Solvents (KarlFischer Reagent Titration Method)3. Significance and Use3.1 Many pine chemical products contain water as a resultof the processes used for their production. Typically refinedproducts such as terpenes, pine oil, tall oil fatty acids, anddist
10、illed tall oil contain only traces of water, but crude tall oilmight contain 0.5 to 2.5 % of water. Although the Karl Fischerand coulometric methods are most applicable to low levels ofmoisture, these can be and are used at higher levels. Theazeotropic distillation method is generally used at higher
11、levels.Moisture By Karl Fischer Titration(Preferred method)4. Apparatus4.1 Titration Vessel, preferably closed, with stirringcapabilities,4.2 Buret, capable of being read at 0.1 mL divisions, orautomatic buret, or4.3 Automatic Karl Fischer titrator.4.4 Balance, capable of weighing to the nearest 0.0
12、001 g.5. Reagents5.1 Karl Fischer Reagent, or Other Suitable Reagent, suchas Pyridine-free Adaptations of Karl Fischer Reagent. Re-agents vary in strength (titer). This test method is written1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, an
13、d Applications and is the direct responsibility ofSubcommittee D01.34 on Pine Chemicals and Hydrocarbon Resins.Current edition approved Dec. 1, 2016. Published December 2016. Originallyapproved in 1946. Last previous edition approved in 2012 as D890 12. DOI:10.1520/D0890-12R16.2This procedure has be
14、en adapted from the method of Karl Fischer published inZeitschrift fr Angewandte Chemie, Vol 48, 1935, p. 395; Chemical Abstracts,Vol29, 1935 p. 6532; as modified by Smith, Bryant, and Mitchell, Journal, Am.Chemical Soc., Vol 61, 1939, p. 2407; and further modified by Axel Johansson,Svensk Pappersti
15、dning, Vol 50, No. 11B, 1947, p. 124; see also Publication 19 of theSwedish Wood Research Institute, Wood Chemistry and Paper Technique (Stock-holm) (1947). Karl Fischer reagent is available from various laboratory supplies.Pyridine-free adaptations of the Karl Fischer reagent are available commerci
16、ally.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO
17、Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by
18、 the World Trade Organization Technical Barriers to Trade (TBT) Committee.1assuming a titer of 5 mg water/mL reagent. Recommendedadditions of water in this test method may need to be adjusteddepending on the titer of the reagent.5.2 MethanolACS grade.6. Standardization of Iodine Reagent6.1 Add metha
19、nol to the titration vessel, and titrate withreagent until the lemon-yellow color just changes to a red-brown color, or, if an automatic titrator is used, until thereadings indicate no free water present. The titration vessel isnow ready for titrating, and is considered conditioned.6.2 Add a drop of
20、 water, weighed to the nearest 0.0001 g, tothe titration vessel by use of a transfer pipet, or a weighingpipet, weighing the pipet before and after the addition. Eachdrop will weigh approximately 0.03 g and will require roughly6 mL of titrant having a titer of 5 mg/mL. Alternatively, a25-L, or other
21、 volume syringe may be used to introduce exactvolumes.6.3 Titrate with reagent until the lemon-yellow color justchanges to a red-brown color, or, if an automatic titrator isused, until the readings indicate no free water present. Recordthe mL of titrant used.6.4 Calculate the water equivalent of the
22、 iodine reagent, inmilligrams of water per millilitre of reagent, as follows:T 5W 31000V(1)where:T = water equivalent of the iodine reagent, mg/mL,W = weighed water added, in g, andV = iodine reagent, mL.7. Procedure7.1 Condition the titration vessel, as described in 6.1.7.2 Add an amount of sample
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD89020122016STANDARDTESTMETHODFORWATERINLIQUIDPINECHEMICALS 液体 松脂 中水 含量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-512417.html