ASTM D850-2018 Standard Test Method for Distillation of Industrial Aromatic Hydrocarbons and Related Materials.pdf
《ASTM D850-2018 Standard Test Method for Distillation of Industrial Aromatic Hydrocarbons and Related Materials.pdf》由会员分享,可在线阅读,更多相关《ASTM D850-2018 Standard Test Method for Distillation of Industrial Aromatic Hydrocarbons and Related Materials.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D850 16D850 18Standard Test Method forDistillation of Industrial Aromatic Hydrocarbons and RelatedMaterials1This standard is issued under the fixed designation D850; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This test method covers
3、 the distillation of industrial aromatic hydrocarbons and related materials of relatively narrow boilingranges from 30 to 250C.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.2 The following applies to all specified limi
4、ts in this test method: for the purposes of determining conformance to this testmethod, an observed or calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressingthe specification limit, in accordance with the rounding-off method of Practice E29.1.3 Wa
5、rningMercury has been designated by EPA and many state agencies as a hazardous material that can cause centralnervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Cautionshould be taken when handling mercury and mercury-containing pro
6、ducts. See the applicable product Safety Data Sheet (SDS) fordetails and EPAs website (http:/www.epa.gov/mercury/faq.htm) for additional information. Users should be aware that sellingmercury or mercury-containing products, or both, in your state may be prohibited by state law.1.4 The values stated
7、in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safe
8、ty, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use. For specific hazard statements, see 6.5.2, 6.6.1 and Section 7.1.6 This international standard was developed in accordance with internationally recognized principles on standardizatio
9、nestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1078 Test Method for Distillation Range of Volatile Orga
10、nic LiquidsD3437 Practice for Sampling and Handling Liquid Cyclic ProductsD4790 Terminology of Aromatic Hydrocarbons and Related ChemicalsD6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related MaterialsE1 Specification for ASTM Liquid-in-Glass Thermome
11、tersE29 Practice for Using Significant Digits in Test Data to Determine Conformance with SpecificationsE133 Specification for Distillation EquipmentE220 Test Method for Calibration of Thermocouples By Comparison TechniquesE691 Practice for Conducting an Interlaboratory Study to Determine the Precisi
12、on of a Test Method1 This test method is under the jurisdiction of ASTM Committee D16 on Aromatic Hydrocarbons Aromatic, Industrial, Specialty and Related Chemicals and is the directresponsibility of Subcommittee D16.04 on Instrumental Analysis.Current edition approved June 1, 2016June 1, 2018. Publ
13、ished July 2016June 2018. Originally approved in 1945. Last previous edition approved in 20112016 asD850 11.D850 16. DOI: 10.1520/D0850-16.10.1520/D0850-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM
14、 Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically pos
15、sible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCo
16、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and 1910.1200 33. Terminology3.1 Definitions:3.1.1 See Terminology D4790 for definitions of terms used in this test method.
17、4. Summary of Test Method4.1 The distillation of a 100-mL sample of industrial aromatic hydrocarbons and related materials is carried out via a carefullycontrolled distillation wherein temperature readings are noted for the first drop of distillate and when 5, 10, and each additional10 up to 90, and
18、 95 % of the sample has distilled over. The temperature corresponding to the dry point is also noted.5. Significance and Use5.1 This test method is suitable for setting specifications, for use as an internal quality control tool, and for use in developmentor research work on industrial aromatic hydr
19、ocarbons and related materials.5.2 This test method gives a broad indication of general purity and can also indicate presence of excessive moisture. It will notdifferentiate between products of similar boiling range.6. Apparatus6.1 Distillation FlaskAstandard 200-mL side-tube, heat-resistant glass d
20、istillation flask as shown in Fig. 1, conforming to thefollowing dimensions:Diameter of bulb, outside, mm 76 1.5Diameter of neck, inside, mm 21 1Height of flask, outside, mm 179 3Vertical distance from bottom of bulb outside tobottom of vapor-tube opening in neck, mm120 3Length of side tube, mm 100
21、3Diameter of side tube, outside, mm 7 0.5Angle of side tube with vertical axis of bulb andneck, 75 3The flask does not comply with Flask C of Specification E133.6.2 Temperature Measurement Devices:6.2.1 Manual Distillation ThermometerThe ASTM Solvents Distillation Thermometer used in the test shall
22、be as prescribedin the specifications for the material being tested. If no thermometer is specified in the material specification, select one from Table1 with the smallest graduations that will cover the entire distillation range of the material being tested. Table 1 lists severalASTMsolvents distil
23、lation thermometers which are suitable for testing industrial aromatic hydrocarbons, and which meet the requirementsof Specification E1.3 Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov
24、.FIG. 1 Distillation FlaskD850 1826.2.2 Automatic Distillation Temperature SensorTemperature measurement systems using thermocouples or resistancethermometers, otherwise referred to as the “temperature measuring devices,” must exhibit the same temperature lag and accuracyas the equivalent mercury gl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD8502018STANDARDTESTMETHODFORDISTILLATIONOFINDUSTRIALAROMATICHYDROCARBONSANDRELATEDMATERIALSPDF

链接地址:http://www.mydoc123.com/p-512312.html