ASTM D618-2008 Standard Practice for Conditioning Plastics for Testing《试验用的塑料调节规程》.pdf
《ASTM D618-2008 Standard Practice for Conditioning Plastics for Testing《试验用的塑料调节规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D618-2008 Standard Practice for Conditioning Plastics for Testing《试验用的塑料调节规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 618 08Standard Practice forConditioning Plastics for Testing1This standard is issued under the fixed designation D 618; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthes
2、es indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 In general, the physical and electrical properties ofplastics are influe
3、nced by temperature and relative humidity ina manner that materially affects test results. In order to makereliable comparisons between different materials and betweendifferent laboratories, it is necessary to standardize the humid-ity conditions, as well as the temperature, to which specimensof the
4、se materials are subjected prior to and during testing. Thispractice defines procedures for conditioning plastics (althoughnot necessarily to equilibrium) prior to testing, and the condi-tions under which they shall be tested.1.2 For some materials, it is possible that a material speci-fication exis
5、ts that requires the use of this practice, but withsome procedural modifications. The material specificationtakes precedence over this practice. Refer to the materialspecification before using this practice. Table 1 in Classifica-tion D 4000 lists the ASTM material specifications thatcurrently exist
6、.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This sta
7、ndard and ISO 291 address the same subject matter,but differ in technical content. ISO 291 describes only two temperatureand humidity conditions for conditioning or testing, or both.2. Referenced Documents2.1 ASTM Standards:2D 709 Specification for Laminated Thermosetting MaterialsD 756 Practice for
8、 Determination of Weight and ShapeChanges of Plastics Under Accelerated Service Condi-tions3D 4000 Classification System for Specifying Plastic Mate-rialsD 5032 Practice for Maintaining Constant Relative Humid-ity by Means of Aqueous Glycerin SolutionsE 104 Practice for Maintaining Constant Relative
9、 Humidityby Means of Aqueous Solutions2.2 ISO Standard:ISO 291 PlasticsStandard Atmospheres for Conditioningand Testing43. Terminology3.1 Definitions:3.1.1 room temperaturea temperature in the range from20 to 30C (68 to 86F).3.1.2 standard laboratory atmospherean atmosphere hav-ing a temperature of
10、23C (73.4F) and a relative humidity of50 % with standard tolerances as specified in Section 8 shall bethe standard laboratory atmosphere.3.1.3 standard laboratory temperaturea temperature of23C (73.4F) with standard tolerance as specified in Section 7shall be the standard laboratory temperature.4. S
11、ignificance and Use4.1 Conditioning of specimens is typically conducted: (1)for the purpose of bringing the material into equilibrium withnormal or average room conditions, (2) simply to obtainreproducible results, regardless of previous history of expo-sure, or (3) to subject the material to abnorm
12、al conditions oftemperature or humidity in order to predict its service behavior.4.2 The conditioning procedures prescribed in this practiceare designed to obtain reproducible results and have thepotential to give physical values somewhat higher or somewhatlower than values under equilibrium at norm
13、al conditions,depending upon the particular material and test. Depending onthe thickness, type of material and its previous history, it ispossible that it would take 20 to 100 days or more to ensuresubstantial equilibrium under normal conditions of humidity1This practice is under the jurisdiction of
14、ASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.50 on Durability of Plastics.Current edition approved Nov. 1, 2008. Published November 2008. Originallyapproved in 1941. Last previous edition approved in 2005 as D 618 - 05.2For referenced ASTM standards, visit the A
15、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New Y
16、ork, NY 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.and temperature. Consequently, conditioning for reproducibil-ity must of necessity be
17、 used for general purchase specifica-tions and product control tests.5. Sampling5.1 Sampling shall be in accordance with the ASTM testmethods for the specific properties to be determined.6. Test Specimens6.1 The numbers and types of test specimens shall be inaccordance with the ASTM test methods for
18、 the specificproperties to be determined.7. Requirements for Conditioning Atmospheres7.1 When data are to be obtained for comparison purposesat a specific temperature, select the test temperature andassociated tolerance from Table 1.7.1.1 Unless otherwise specified, tolerance for temperatureshall be
19、 as given in Table 1.7.1.2 When a tolerance of 61C (61.8F) is required, itshall be specified and shall be reported.7.1.3 The position for measurement of temperature andrelative humidity measurementmeasurements shall be madeas close as possible to the center of the room or chamber.7.1.3.1 It is possi
20、ble that the temperature and relativehumidity measured are not representative of a conditionelsewhere in an enclosure or room because of local effects ordeficiency in circulation of air. If required, additional measure-ments shall be made throughout the area to show compliance tothe temperature and
21、relative humidity conditions specified.7.2 Relative Humidity:7.2.1 When tolerance for temperature is 62C, the tolerancefor relative humidity shall be 610 %.7.2.2 When tolerance for temperature is 61C, the tolerancefor relative humidity shall be 65%.NOTE 2Annex B of ISO 291 provides background inform
22、ation on thecalculation of tolerance for relative humidity based on the allowedfluctuation in set point temperature.8. Designations for Conditioning8.1 Designation for Conditioning Prior to Test:8.1.1 Designate conditioning of test specimens as follows:8.1.1.1 A number indicating in hours the durati
23、on of theconditioning,8.1.1.2 A number indicating in degrees Celsius the condi-tioning temperature, or8.1.1.3 A number indicating relative humidity, wheneverrelative humidity is controlled, or a word to indicate immersionin a liquid.8.1.2 The numbers shall be separated from each other byslant marks.
24、 A sequence of conditions shall be denoted by useof a plus ( + ) sign between successive conditions. “Des” shallbe used to indicate desiccation over anhydrous calcium chlo-ride. Temperature and relative humidity tolerances shall be inaccordance with Section 7, unless otherwise specified.NOTE 3Exampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6182008STANDARDPRACTICEFORCONDITIONINGPLASTICSFORTESTING 试验 塑料 调节 规程 PDF

链接地址:http://www.mydoc123.com/p-511978.html