ASTM D562-2010 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer《斯氏(Stormer)粘度计测定油漆稠度(Krebs粘度单位)的标准试验方法》.pdf
《ASTM D562-2010 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer《斯氏(Stormer)粘度计测定油漆稠度(Krebs粘度单位)的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D562-2010 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer《斯氏(Stormer)粘度计测定油漆稠度(Krebs粘度单位)的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D562 10Standard Test Method forConsistency of Paints Measuring Krebs Unit (KU) ViscosityUsing a Stormer-Type Viscometer1This standard is issued under the fixed designation D562; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method
3、covers the measurement of Krebs Unit(KU) viscosity to evaluate the consistency of paints and relatedcoatings using the Stormer-type viscometer.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purpo
4、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1 S
5、pecification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 consistency, nload in grams to produce a rotationalfrequency of 200 r/min (Stormer Viscometer)3.1.2 Krebs units (KU), nvalues of a scale commonlyused to express the consistency of
6、 paints generally applied bybrush or roller.3.1.2.1 DiscussionThis scale is a function of the “load toproduce 200-r/min” scale.4. Summary of Test Method4.1 The load required to produce a rotational frequency of200 r/min for an offset paddle rotor immersed in a paint isdetermined.5. Significance and
7、Use5.1 This test method provides values that are useful inspecifying and controlling the consistency of paints, such asconsumer or trade sales products.METHOD A6. Apparatus6.1 Viscometer, Stormer, with the paddle-type rotor asillustrated in Fig. 1 and Fig. 2. The stroboscopic timerattachment in Fig.
8、 1 can be removed and the instrument usedwithout it but with a sacrifice of speed and accuracy. Thestroboscopic timer gives the 200 r/min reading directly.6.2 Container, 500-mL (1-pt), 85 mm (338 in.) in diameter.6.3 ThermometerAn ASTM Stormer Viscosity thermom-eter having a range from 20 to 70C and
9、 conforming to therequirements for Thermometer 49C, as prescribed in Specifi-cation E1. In addition, temperature measuring devices such asnon-mercury liquid-in-glass thermometers, thermocouples, orplatinum resistance thermometers that provide equivalent orbetter accuracy and precision, that cover th
10、e temperature rangefor thermometer 49C, may be used.6.4 Stopwatch, or suitable timer measuring to 0.2 s.6.5 Weights, a set covering the range from 5 to 1000 g.7. Materials7.1 Two standard oils, calibrated in absolute viscosity(poise), that are within the viscosity range of the coatings to bemeasured
11、. These oils should differ in viscosity by at least 5 P.NOTE 1The normal range of the Stormer is covered by oils havingviscosities of 4 P (70 KU), 10 P (85 KU), and 14 P (95 KU).7.1.1 Suitable standards are silicone, hydrocarbon, linseed,and castor oils. Silicone and hydrocarbon oils calibrated inpo
12、ises are commercially available. Uncalibrated linseed andcastor oils may be calibrated with any apparatus that providesmeasurements of absolute viscosity.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct resp
13、onsibility ofSubcommittee D01.24 on Physical Properties of Liquid Paints and Paint Materials.Current edition approved July 1, 2010. Published July 2010. Originally approvedin 1947. Last previous edition approved in 2005 as D562 01 (2005). DOI:10.1520/D0562-10.2For referenced ASTM standards, visit th
14、e ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
15、United States.7.1.2 Assign a value of load to produce 200 r/min to each oilby converting its viscosity value in poises to load in grams bythe following equation:3L 5 610O 1 906.6 D!/30where:O = viscosity of oil in poises andD = density of oil.8. Calibration48.1 Remove the rotor and weight carrier fr
16、om the viscom-eter. Make sure the string is wound evenly on the drum anddoes not overlap itself.8.2 Attach a 5-g weight onto the string and then release thebrake. If the viscometer starts to run from this dead start andcontinues to run through several revolutions of the string drum,it is satisfactor
17、y for use. If it does not start unaided when the5-g weight is applied, the instrument should be reconditioned.8.3 Check the dimensions of the paddle-type rotor. Theyshould be within 0.1 mm (60.004 in.) of the dimensions shownin Fig. 2.8.4 Select two standard oils having assigned values of loadto pro
18、duce 200 r/min within the range of the values expectedfor the coatings to be measured (see 7.1).8.5 Adjust the temperature of the standard oils to 25 60.2C. The temperature of the Stormer apparatus should be thesame. If the specified temperature cannot be obtained, recordthe temperature of the oil a
19、t the beginning and end of test to0.2C.8.6 Determine the load in grams to produce 200 r/min witheach of the two oils, using either Procedure A described inSection 9 or Procedure B described in Section 10.8.6.1 If the oil temperature was not at 25 6 0.2C during thetest, correct the measured load in g
20、rams for the deviation fromthat temperature.NOTE 2Load corrections for deviations of oil temperature from thespecified temperature can be made by means of a previously establishedplot of load versus oil temperature (see Appendix X1).8.7 If the measured load (corrected for any temperaturedeviation fr
21、om standard) is within 615 % of the assigned loadvalues for the oils, the Stormer apparatus can be considered tobe in satisfactory calibration.9. Procedure A (Without Stroboscopic Attachment)9.1 Thoroughly mix the sample and strain it into a 500-mL(1-pt) container to within 20 mm (34 in.) of the top
22、.9.2 Bring the temperature of the specimen to 25 6 0.2Cand maintain it at that temperature during the test. Thetemperature of the Stormer apparatus should be the same.9.2.1 If the specified temperature cannot be obtained, recordthe temperature of the specimen at the beginning and end oftest to 0.2C.
23、9.3 When the temperature of the specimen has reachedequilibrium, stir it vigorously, being careful to avoid entrap-ping air, and place the container immediately on the platformof the viscometer so that the paddle-type rotor is immersed inthe material to the mark on the shaft of the rotor.3Geddes, J.
24、 A., and Dawson, D. H., “Calculation of Viscosity From StormerViscosity Data,” Industrial and Engineering Chemistry, Vol 34, 1942, p. 163.4Jackson, C. F., and Madson, W. H., “AMethod for the Standardization of KrebsModified Stormer Viscometers,” ASTM Bulletin, No. 161, 1949.FIG. 1 Stormer Viscometer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5622010STANDARDTESTMETHODFORCONSISTENCYOFPAINTSMEASURINGKREBSUNITKUVISCOSITYUSINGASTORMERTYPEVISCOMETER

链接地址:http://www.mydoc123.com/p-511882.html