ASTM D470-2005 Standard Test Methods for Crosslinked Insulations and Jackets for Wire and Cable《电线和电缆用交联绝缘材料与套管的标准试验方法》.pdf
《ASTM D470-2005 Standard Test Methods for Crosslinked Insulations and Jackets for Wire and Cable《电线和电缆用交联绝缘材料与套管的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D470-2005 Standard Test Methods for Crosslinked Insulations and Jackets for Wire and Cable《电线和电缆用交联绝缘材料与套管的标准试验方法》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 470 05An American National StandardStandard Test Methods forCrosslinked Insulations and Jackets for Wire and Cable1This standard is issued under the fixed designation D 470; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods
3、 cover procedures for testingcrosslinked insulations and jackets for wire and cable. Todetermine the test to be made on the particular insulation orjacket, refer to the product specification for that type. Thesetest methods do not apply to the class of products known asflexible cords.1.2 This standa
4、rd does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardssee Secti
5、on 4.1.3 Whenever two sets of values are presented, in differentunits, the values in the first set are the standard, while those inthe parentheses are for information only.1.4 In many instances the insulation or jacket cannot betested unless it has been formed around a conductor or cable.Therefore,
6、tests are done on insulated or jacketed wire or cablein these test methods solely to determine the relevant propertyof the insulation or jacket and not to test the conductor orcompleted cable.1.5 The procedures appear in the following sections:SectionsAC and DC Voltage Withstand Tests 22 to 29Capaci
7、tance and Dissipation Factor Tests 38 to 44Cold Bend 128Cold Bend, Long-Time Voltage Test on Short Specimens 51 to 57Double AC Voltage Test on Short Specimens 45 to 50Electrical Tests of Insulation 17 to 64Heat Distortion Test 127Horizontal Flame Test 100 to 104Insulation Resistance Tests on Complet
8、ed Cable 30 to 37Mineral Filler Content, Determination of 111 to 115Ozone Resistance Test 87 to 99Partial-Discharge Test 58 to 64Physical Tests of Insulation and Jacket Compounds 5 to 16Surface Resistivity Test 116 to 120Track Resistance Test 129 to 132U-Bend Discharge Test 121 to 125Water Absorptio
9、n Test 65 to 71Water Absorption Test, Accelerated 72 to 86Water Absorption Test on Fibrous Coverings 105 to 1102. Referenced Documents2.1 ASTM Standards:2D 149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD
10、 150 Test Methods for AC Loss Characteristics and Per-mittivity (Dielectric Constant) of Solid Electrical Insulat-ing MaterialsD 257 Test Methods for D-C Resistance or Conductance ofInsulating MaterialsD 412 Test Methods for Vulcanized Rubber and Thermo-static ElastomersTensionD 454 Test Method for
11、Rubber-Deterioration by Heat andAir PressureD 572 Test Method for Rubber-Deterioration by Heat andOxygenD 573 Test Method for Rubber-Deterioration in anAir OvenD 1193 Specification for Reagent WaterD 1711 Terminology Relating to Electrical InsulationD 2132 Test Method for Dust-and-Fog Tracking and E
12、ro-sion Resistance of Electrical Insulating MaterialsD 3755 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating MaterialsUnder Direct-Voltage StressD 5025 Specification for a Laboratory Burner Used forSmall-Scale Burning Tests on Plastic MaterialsD 5207
13、 Practice for Calibration of 20-mm (50-W) and125-mm (500-W) Test Flames for Small-Scale BurningTests on Plastic MaterialsD 5423 Specification for Forced-Convection LaboratoryOvens for Evaluation of Electrical Insulation2.2 ICEA Standard:T-24-380 Guide for Partial-Discharge Procedure31These test meth
14、ods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.18 on Solid Insulations, Non-Metallic Shieldings, and Cover-ings for Electrical and Telecommunications Wire and Cables.Current edition approved S
15、eptember 1, 2005. Published September 2005.Originally approved in 1937. Last previous edition approved in 1999 as D 470 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, re
16、fer to the standards Document Summary page onthe ASTM website.3Available from the Insulated Cable Engineers Assoc., P.O. Box 440, SouthYarmouth, MA 02664.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 DefinitionsFo
17、r definitions of terms used in these testmethods, refer to Terminology D 1711.3.2 Definition of Term Specific to this Standard:3.2.1 aging (act of), nexposure of material to air or oil ata temperature and time as specified in the relevant materialspecification for that material.3.3 Symbol:3.3.1 kcmi
18、lthousands of circular mils.4. Hazards4.1 Mercury:4.1.1 Mercury metal vapor poisoning has long been recog-nized as a hazard in industry. The exposure limits are set bygovernmental agencies and are usually based upon recommen-dations made by the American Conference of GovernmentalIndustrial Hygienist
19、s.4The concentration of mercury vaporover spills from broken thermometers, barometers, and otherinstruments using mercury can easily exceed these exposurelimits. Mercury, being a liquid with high surface tension andquite heavy, will disperse into small droplets and seep intocracks and crevices in th
20、e floor. This increased area ofexposure adds significantly to the mercury vapor concentrationin air. The use of a commercially available emergency spill kitis recommended whenever a spill occurs. Mercury vaporconcentration is easily monitored using commercially avail-able sniffers. Make spot checks
21、periodically around operationswhere mercury is exposed to the atmosphere. Make thoroughchecks after spills. See 8.3.2 and 8.3.3.4.2 High Voltage:4.2.1 Lethal voltages may be present during these tests. It isessential that the test apparatus, and all associated equipmentthat may be electrically conne
22、cted to it, be properly designedand installed for safe operation. Solidly ground all electricallyconductive parts that any person might come in contact withduring the test. Provide means for use at the completion of anytest to ground any parts which: were at high voltage during thetest; may have acq
23、uired an induced charge during the test; mayretain a charge even after disconnection of the voltage source.Thoroughly instruct all operators in the proper way to conducttests safely. When making high voltage tests, particularly incompressed gas or in oil, the energy released at breakdownmay be suffc
24、ient to result in fire, explosion, or rupture of thetest chamber. Design test equipment, test chambers, and testspecimens so as to minimize the possibility of such occurrencesand to eliminate the possibility of personal injury. See Sections20, 27, 33, 42, 48, 54, 62, 68, 76, 118, 123 and 130.4.3 Ozo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD4702005STANDARDTESTMETHODSFORCROSSLINKEDINSULATIONSANDJACKETSFORWIREANDCABLE 电线 电缆 交联 绝缘材料 套管 标准

链接地址:http://www.mydoc123.com/p-511757.html