ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf
《ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 422 63 (Reapproved 2007)Standard Test Method forParticle-Size Analysis of Soils1This standard is issued under the fixed designation D 422; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the quantitative determinationof the distribution of particle sizes in soils. The distribution ofparticle size
3、s larger than 75 m (retained on the No. 200 sieve)is determined by sieving, while the distribution of particle sizessmaller than 75 m is determined by a sedimentation process,using a hydrometer to secure the necessary data (Note 1 andNote 2).NOTE 1Separation may be made on the No. 4 (4.75-mm), No. 4
4、0(425-m), or No. 200 (75-m) sieve instead of the No. 10. For whateversieve used, the size shall be indicated in the report.NOTE 2Two types of dispersion devices are provided: (1) a high-speed mechanical stirrer, and (2) air dispersion. Extensive investigationsindicate that air-dispersion devices pro
5、duce a more positive dispersion ofplastic soils below the 20-m size and appreciably less degradation on allsizes when used with sandy soils. Because of the definite advantagesfavoring air dispersion, its use is recommended. The results from the twotypes of devices differ in magnitude, depending upon
6、 soil type, leading tomarked differences in particle size distribution, especially for sizes finerthan 20 m.2. Referenced Documents2.1 ASTM Standards:2D 421 Practice for Dry Preparation of Soil Samples forParticle-Size Analysis and Determination of Soil Con-stantsE11 Specification for Wire Cloth and
7、 Sieves for TestingPurposesE 100 Specification for ASTM Hydrometers2.2 ASTM Adjuncts:Air-Jet Dispersion Cup for Grain-Size Analysis of Soil33. Apparatus3.1 BalancesA balance sensitive to 0.01 g for weighingthe material passing a No. 10 (2.00-mm) sieve, and a balancesensitive to 0.1 % of the mass of
8、the sample to be weighed forweighing the material retained on a No. 10 sieve.3.2 Stirring ApparatusEither apparatus A or B may beused.3.2.1 Apparatus A shall consist of a mechanically operatedstirring device in which a suitably mounted electric motor turnsa vertical shaft at a speed of not less than
9、 10 000 rpm withoutload. The shaft shall be equipped with a replaceable stirringpaddle made of metal, plastic, or hard rubber, as shown in Fig.1. The shaft shall be of such length that the stirring paddle willoperate not less than34 in. (19.0 mm) nor more than 112 in.(38.1 mm) above the bottom of th
10、e dispersion cup. A specialdispersion cup conforming to either of the designs shown inFig. 2 shall be provided to hold the sample while it is beingdispersed.3.2.2 Apparatus B shall consist of an air-jet dispersion cup(See drawing3)(Note 3) conforming to the general detailsshown in Fig. 3 (Note 4 and
11、 Note 5).NOTE 3The amount of air required by an air-jet dispersion cup is ofthe order of 2 ft3/min; some small air compressors are not capable ofsupplying sufficient air to operate a cup.NOTE 4Another air-type dispersion device, known as a dispersiontube, developed by Chu and Davidson at Iowa State
12、College, has beenshown to give results equivalent to those secured by the air-jet dispersioncups. When it is used, soaking of the sample can be done in thesedimentation cylinder, thus eliminating the need for transferring theslurry. When the air-dispersion tube is used, it shall be so indicated in t
13、hereport.NOTE 5Water may condense in air lines when not in use. This watermust be removed, either by using a water trap on the air line, or byblowing the water out of the line before using any of the air for dispersionpurposes.3.3 HydrometerAn ASTM hydrometer, graduated to readin either specific gra
14、vity of the suspension or grams per litre ofsuspension, and conforming to the requirements for hydrom-eters 151H or 152H in Specifications E 100. Dimensions ofboth hydrometers are the same, the scale being the only item ofdifference.1This test method is under the jurisdiction ofASTM Committee D18 on
15、 Soil andRock and is the direct responsibility of Subcommittee D18.03 on Texture, Plasticityand Density Characteristics of Soils.Current edition approved Oct. 15, 2007. Published October 2007. Originallyapproved in 1935. Last previous edition approved in 2002 as D 422 63 (2002)e1.2For referenced AST
16、M standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Adjunct No.ADJD0422.1Copy
17、right ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.4 Sedimentation CylinderAglass cylinder essentially 18in. (457 mm) in height and 212 in. (63.5 mm) in diameter, andmarked for a volume of 1000 mL. The inside diameter shall besuch that the
18、 1000-mL mark is 36 6 2 cm from the bottom onthe inside.3.5 ThermometerA thermometer accurate to 1F (0.5C).3.6 SievesA series of sieves, of square-mesh woven-wirecloth, conforming to the requirements of Specification E11.Afull set of sieves includes the following (Note 6):3-in. (75-mm) No. 10 (2.00-
19、mm)2-in. (50-mm) No. 20 (850-m)112-in. (37.5-mm) No. 40 (425-m)1-in. (25.0-mm) No. 60 (250-m)34-in. (19.0-mm) No. 140 (106-m)38-in. (9.5-mm) No. 200 (75-m)No. 4 (4.75-mm)NOTE 6Aset of sieves giving uniform spacing of points for the graph,as required in Section 17, may be used if desired. This set co
20、nsists of thefollowing sieves:3-in. (75-mm) No. 16 (1.18-mm)112-in. (37.5-mm) No. 30 (600-m)34-in. (19.0-mm) No. 50 (300-m)38-in. (9.5-mm) No. 100 (150-m)No. 4 (4.75-mm) No. 200 (75-m)No. 8 (2.36-mm)3.7 Water Bath or Constant-Temperature RoomA waterbath or constant-temperature room for maintaining t
21、he soilsuspension at a constant temperature during the hydrometeranalysis. A satisfactory water tank is an insulated tank thatmaintains the temperature of the suspension at a convenientconstant temperature at or near 68F (20C). Such a device isillustrated in Fig. 4. In cases where the work is perfor
22、med in aroom at an automatically controlled constant temperature, thewater bath is not necessary.3.8 BeakerA beaker of 250-mL capacity.3.9 Timing DeviceA watch or clock with a second hand.4. Dispersing Agent4.1 A solution of sodium hexametaphosphate (sometimescalled sodium metaphosphate) shall be us
23、ed in distilled ordemineralized water, at the rate of 40 g of sodiumhexametaphosphate/litre of solution (Note 7).NOTE 7Solutions of this salt, if acidic, slowly revert or hydrolyzeback to the orthophosphate form with a resultant decrease in dispersiveaction. Solutions should be prepared frequently (
24、at least once a month) oradjusted to pH of 8 or 9 by means of sodium carbonate. Bottles containingMetric Equivalentsin. 0.001 0.049 0.2031234mm 0.03 1.24 5.16 12.7 19.0FIG. 1 Detail of Stirring PaddlesMetric Equivalentsin. 1.3 2.6 3.75mm 33 66 95.2FIG. 2 Dispersion Cups of ApparatusD 422 63 (2007)2s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42219632007STANDARDTESTMETHODFORPARTICLESIZEANALYSISOFSOILS 土壤 粒度 分析 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511684.html