ASTM D413-1998(2002)e1 Standard Test Methods for Rubber Property&8212 Adhesion to Flexible Substrate《粘合到软质基底的橡胶特性的标准试验方法》.pdf
《ASTM D413-1998(2002)e1 Standard Test Methods for Rubber Property&8212 Adhesion to Flexible Substrate《粘合到软质基底的橡胶特性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D413-1998(2002)e1 Standard Test Methods for Rubber Property&8212 Adhesion to Flexible Substrate《粘合到软质基底的橡胶特性的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 413 98 (Reapproved 2002)e1Standard Test Methods forRubber PropertyAdhesion to Flexible Substrate1This standard is issued under the fixed designation D 413; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTESection 2 was editorially updated in Febru
3、ary 2003.1. Scope1.1 These test methods cover the determination of theadhesion strength between plies of fabric bonded with rubberor the adhesion of the rubber layer in articles made from rubberattached to other material. They are applicable only when theadhered surfaces are approximately plane or u
4、niformly circularas in belting, hose, tire carcasses, or rubber-covered sheetmetal.1.2 When the adhered surfaces contain sharp bends, angles,or other gross irregularities that cannot be avoided in preparingtest specimens, special test methods must be employed forevaluating adhesion.1.3 The values st
5、ated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
6、and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 3040 Practice for Preparing Precision Statements forStandards Related to Rubber and Rubber Testing2D 3182 Practice for RubberMaterials, Equipment, andProcedures fo
7、r Mixing Standard Compounds and Prepar-ing Standard Vulcanized Sheets3D 3183 Practice for RubberPreparation of Pieces for TestPurposes from Products33. Summary of Test Method3.1 Two general test methods are given:3.1.1 Static-Mass Method, in which the force required tocause separation between adhere
8、d surfaces is applied by meansof gravity acting on a mass.3.1.2 Machine Method, in which the force required to causeseparation between adhered surfaces is applied by means of atension machine.3.2 Except as may be otherwise specified in these testmethods, the requirements of Practices D 3182 and D 31
9、83,shall be complied with and are made a part of these testmethods.3.3 In case of conflict between the provisions of these testmethods and those of detailed specifications or test methods fora particular material, the latter shall take precedence.3.4 As covered by these test methods, an adhesion tes
10、tconsists of applying to a test specimen, under specifiedconditions, a (measured) force sufficient to strip from thespecimen at a measured rate, a layer of moderate thicknesswith separation (rupture, tearing) at the adhered surfaces. Thenumerical value of the adhesion is expressed as (1) the average
11、force required to cause separation at a definite rate, or (2) theaverage rate of separation caused by a known or specifiedforce. In the machine test method, the rate of separation is fixedand the adhesion value must be expressed in terms of themeasured force. With the static-mass test method, either
12、 (1)or(2) can be used, but the latter is preferable and will be hereemployed.4. Significance and Use4.1 These test methods are used to ensure the quality of aproduct by determining the force per unit width required toseparate a rubber layer from a flexible substrate such as fabric,fibre, wire, or sh
13、eet metal. The acceptable value of adhesionmeasured will, of course, vary from product to product due todifferent rubber formulations, flexible substrates, and types ofproducts. However, once a product is established, minimumvalues of separation force can be determined and agreed to by1These test me
14、thods are under the jurisdiction of ASTM Committee D11 onRubber and are the direct responsibility of Subcommittee D11.25 on RubberAdhesive Systems.Current edition approved Dec. 10, 2002. Published February 2003. Originallyapproved in 1935. Last previous edition approved in 1998 as D 413 98.2Disconti
15、nuedsee 1986 Annual Book of ASTM Standards, Vols. 09.01 and09.02.3Annual Book of ASTM Standards, Vol 09.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.producer and consumer and both can monitor to assuremaintenance of the agreed-
16、upon minimum value.STATIC-MASS METHOD5. Apparatus5.1 The apparatus required for the adhesion test by thestatic-mass test method consists of a supporting frame, testingclamps, mandrels, calibrated masses, and mass carriers. Thesupporting frame is of such design that clamps for stripspecimens hang on
17、it vertically and that mandrels for ringspecimens are supported on it horizontally. The frame hassufficient height to permit the mass carrier to be suspendedfrom the test specimens by means of clamps and to hang freelyduring the progress of the test. Provision also is made tosupport the mandrels so
18、that they revolve freely with minimumfriction. Suitable apparatus is shown in Fig. 1 and Fig. 2.6. Test Specimens6.1 Strip SpecimensType APlane strips having a widthof 25 + 3, 0 mm (1 + 0.125, 0 in.), and a minimum lengthsuch as to permit 180 peel separation over sufficient distanceto indicate the a
19、dhesion value.6.1.1 Cut the specimen to 25 + 3, 0 mm (1 + 0.125 0in.) wide. The thickness will vary according to the constructionof the article being tested. The maximum thickness of thespecimen is limited to 13 mm (0.5 in.). To comply with thisrequirement, slice or buff the specimen. The ply or lay
20、er beingseparated should never be over 6.5 mm (0.25 in.) thick.6.1.2 Cut the specimen from the article in such a mannerthat the adhered parts have the same width where practicable.The technique used in 6.2.2 and 6.2.3 may be applied here.When necessary, or specified, cut only the layer to be separat
21、ed(by application of load) to the prescribed width. In such cases,remove the portions of that layer remaining outside of the testwidth to avoid edge constriction during separation.6.1.3 Curved specimens for test in strip form shall havecurvature only in the length dimension of the specimen.6.2 Strip
22、 SpecimensType BThe same as Type A, withthe exception of 90 peel and the separation line in the centerof the specimen.6.2.1 Cut the specimen 35 mm (138 in.) wide. Remove theexcess plies to obtain a thickness of 6 mm (14 in.) and leave theseparation line in the center of the specimen to ensure a 90pe
23、el.6.2.2 Buff to a width of 30 mm (118 in.) with a coarse gritemery cloth (grit No. 40) with care to prevent burning orgumming the sides of the specimen.6.2.3 Make a 2-mm (116-in.) deep slit with a knife alongeach side exactly where the specimen is to be separated duringtesting. Use a knife with an
24、adjustable blade where only thedesired depth of cut (2 mm) of blade is exposed.6.3 Ring SpecimensClosed rings having a width of 25 mm(1 in.) and maximum internal diameter of 100 mm (4 in.).6.3.1 Mount the article on a smooth, close-fitting, slightlytapered wooden mandrel.6.3.2 Rotate the mandrel (a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD41319982002E1STANDARDTESTMETHODSFORRUBBERPROPERTY8212ADHESIONTOFLEXIBLESUBSTRATE 粘合 到软质 基底 橡胶 特性

链接地址:http://www.mydoc123.com/p-511679.html