ASTM D352-1997(2016) Standard Test Methods for Pasted Mica Used in Electrical Insulation《电气绝缘中粘贴用云母的标准试验方法》.pdf
《ASTM D352-1997(2016) Standard Test Methods for Pasted Mica Used in Electrical Insulation《电气绝缘中粘贴用云母的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D352-1997(2016) Standard Test Methods for Pasted Mica Used in Electrical Insulation《电气绝缘中粘贴用云母的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D352 97 (Reapproved 2016)Standard Test Methods forPasted Mica Used in Electrical Insulation1This standard is issued under the fixed designation D352; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the testing of bonded micasplittings and bonded mica paper to be used for commutatorinsulation, hot m
3、olding, heater plates, and other similar insu-lating purposes.1.2 These test methods appear in the following sections:Test SectionsCompressive Creep 410Dielectric Strength 3841Mica or Binder Content 19Molding Test 3136Organic Binder 2024Resistivity 4246Silicone Binder 2530Stability Under Heat and Pr
4、essure 11181.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, i
5、f any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 40.1 and 45.1for specific hazard statements.2. Referenced Documents2.1 ASTM Standard
6、s:2D149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD1711 Terminology Relating to Electrical Insulation3. Terminology3.1 Definitions
7、:3.1.1 For definitions of terms relating to electricalinsulation, refer to Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 binder content, n, (of pasted mica)the percent byweight of binder relative to the original weight of a specimenas determined by procedures specified h
8、erein.3.2.1.1 DiscussionBinder content includes any residualsolvent. Pasted mica materials not fully cured (such as moldingand flexible plates) may contain appreciable quantities ofsolvent in the binder. This solvent is usually later removedwhen the material is cured in the manufacture of electrical
9、equipment. In such cases, the binder content after cure is less(by the amount of solvent removed) than would be determinedby this method. To determine the binder content after cure ofmaterials that are not fully cured, but subsequently will be, it isnecessary, before initially weighing the specimen,
10、 to heat thespecimen for a time and at a temperature that depends upon thematerial from which the specimen is prepared.3.2.2 compressive creep, nthe change in thickness of abonded micaceous material resulting from exposure to elevatedtemperature for a specified time while a specimen is under aspecif
11、ied compressive load.3.2.3 mica content, n, (of pasted mica)the percent byweight of mica relative to the original weight equal to 100 %minus the binder content as determined by procedures specifiedherein.COMPRESSIVE CREEP4. Significance and Use4.1 This test determines the compressive creep under lab
12、o-ratory conditions or under conditions that may be encounteredduring manufacture of electrical equipment. It has specialsignificance if the material to be tested is applied as commu-tator segment insulation. It serves as a measure under specifiedconditions of the ability of the material to resist d
13、eformationwhile under compressive load, during exposure to elevatedtemperature for a specified time. This test is suitable foracceptance tests and for manufacturing control.1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are t
14、he direct responsibility ofSubcommittee D09.19 on Dielectric Sheet and Roll Products (Disbanded 4/2016).Current edition approved May 15, 2016. Published May 2016. Originallyapproved in 1932. Last previous edition approved in 2008 as D352 97 (2008)1.DOI: 10.1520/D0352-97R16.2For referenced ASTM stand
15、ards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
16、 19428-2959. United States15. Apparatus5.1 Hydraulic PressA hydraulic press having temperaturecontrolled, electrically heated platens, or a press with otherprovisions for heating the specimen and controlling the tem-perature. The platens shall be at least 4 by 4 in. (102 by 102mm) in size. The press
17、 shall be capable of exerting a force ofat least 4000 lb (18 kN). The apparatus shall be capable ofmaintaining a specimen temperature of at least 200 6 5C. Itis preferable that the apparatus have platens with water ducts orother provisions for cooling the specimen. (See Note 1 in 7.3.)5.2 Pressure G
18、ageApressure gage capable of determiningthe pressure on the specimen with an accuracy of 65%.5.3 Thickness GageA thickness gage capable of measur-ing the thickness of the specimen to the nearest 0.001 in. (0.025mm).5.4 PotentiometerTemperature measuring instrument anda No. 30 AWG or smaller thermoco
19、uple with overall accuracyof 6 2C for measurement of specimen temperature.5.5 Steel PlatesTwo 4 by 4-in. (102 by 102-mm) or largerpolished steel plates of at least116-in. (1.6-mm) thickness,surface ground so that the top and bottom surfaces of eachpiece are parallel, one plate each for the top and b
20、ottom of thetest specimen.6. Test Specimen6.1 The test specimen shall consist of a sufficient number ofpieces of bonded micaceous plate, 2 by 2 in. (51 by 51 mm) insize, to form a stack approximately but not greater than 1.000in. (25.40 mm) in thickness. The pieces shall be selected so asto be repre
21、sentative of the entire sheet.At least three specimensshall be tested for each lot of material.7. Procedure7.1 Center the stacked specimen between the 4 by 4-in. (102by 102-mm) steel plates and then center this assembly in thepress. Place the thermocouple between pieces near the middleof the stack.
22、Carefully align the stack to form a right parallel-epiped. Apply a pressure of 1000 psi (7 MPa) to the specimensurfaces, and carefully determine the average thickness of thestack by means of the gage. Where inside gages are used,measure the thickness at each of the four corners as close to thespecim
23、en as possible. Measurements shall be made within 5min.7.2 Pack approximately 2 in. (51 mm) of thermal insulationmaterial around the specimen without disturbing it. Heat thespecimen to 160 6 5C or 200 6 5C as specified. The timerequired to reach the specified temperature should be not lessthan 30 mi
24、n nor more than 75 min. The platen temperatureshall not exceed the specified temperature by more than thespecified tolerance. If the specimen is heated by other means,the surrounding medium shall not exceed the specified tem-perature by more than the specified tolerance. Allow thespecimen to remain
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD35219972016STANDARDTESTMETHODSFORPASTEDMICAUSEDINELECTRICALINSULATION 电气 绝缘 粘贴 云母 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511586.html