ASTM D348-2013 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电绝缘用刚性管的标准试验方法》.pdf
《ASTM D348-2013 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电绝缘用刚性管的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D348-2013 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电绝缘用刚性管的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D348 07D348 13 An American National StandardStandard Test Methods forRigid Tubes Used for Electrical Insulation1This standard is issued under the fixed designation D348; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods cover
3、 the testing of rigid tubes used in electrical insulation. These tubes include many types made fromfibrous sheets of basic materials, such as cellulose, glass, or nylon, in the form of paper, woven fabrics, or mats, bonded togetherby natural or synthetic resins or by adhesives. Such tubes include vu
4、lcanized fiber and thermosetting laminates, as well as tubesmade from cast, molded, or extruded natural or synthetic resins, with or without fillers or reinforcing materials.1.2 Tubes tested by these test methods are most commonly circular in cross section; however, noncircular shapes are also incom
5、mercial use. To the extent that the individual methods are compatible with a particular noncircular shape, these test methodsare applicable to these other shapes. For tests on noncircular tubes, appropriate comments shouldshall be included in the test report,including details of orientation of test
6、specimens with respect to the cross section of the tube.1.3 The procedures appear in the following sections:Procedure SectionsASTM TestMethodReferenceCompressive Strength (Axial and Diametral) 12 to 17 E4Conditioning. 4 .Density 20 to 24 .Dielectric Strength 25 to 32 D149Dimensional Measurements 5 D
7、668Dissipation Factor and Permittivity 33 to 35 D150Tensile Strength 6 to 11 E4Water Absorption 18 to 19 D5701.4 The values stated in inch-pound units are to be regarded as the standard. SI units in parentheses are for information only.1.5 This standard does not purport to address all of the safety
8、concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For a specific hazard statement, see 27.1.1.2. Referenced Documents2.1 ASTM Stan
9、dards:2D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials atCommercial Power FrequenciesD150 Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical InsulationD570 Test Method for Water Absorp
10、tion of PlasticsD668 Test Methods of Measuring Dimensions of Rigid Rods and Tubes Used for Electrical InsulationD1711 Terminology Relating to Electrical InsulationE4 Practices for Force Verification of Testing Machines3. Terminology3.1 DefinitionsFor definitions of terms used in these test methods,
11、refer to Terminology D1711.1 These test methods are under the jurisdiction ofASTM Committee D09 on Electrical and Electronic Insulating Materials and are the direct responsibility of SubcommitteeD09.07 on Flexible and Rigid Insulating Materials.Current edition approved Feb. 1, 2007Nov. 1, 2013. Publ
12、ished February 2007November 2013. Originally approved in 1932. Last previous edition approved in 20002007as D348 00.D348 07. DOI: 10.1520/D0348-07.10.1520/D0348-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book
13、 of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technic
14、ally possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this st
15、andardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Conditioning4.1 In order to eliminate the effects of previous history of humidity exposure and to obtain reproducible results (Note 1), thetest specimens in all cases of dispute
16、, shall be given a conditioning treatment for physical tests (Note 2) as follows:4.1.1 Tensile Strength, Compressive Strength (Axial and Diametral), and DensityCondition the machined specimens prior totest by drying in an air-circulating oven for 48 h at 50 6 3 C, followed by cooling to room tempera
17、ture in a desiccator. In eithercase, all specimens shall be tested at room temperature maintained at 23 6 2 C, 50 % relative humidity.NOTE 1Conditioning of specimens may be undertaken: The following are potential reasons to undertake conditioning of specimens: (a) for thepurpose of bringing the mate
18、rial into equilibrium with standard laboratory atmospheric conditions of 23 C and 50 % relative humidity; (b) simply toobtain reproducible results, irrespective of previous history of exposure; or (c) to subject the material to abnormal conditions of temperature or humidityin order to predict its se
19、rvice behavior.The conditions given here to obtain reproducible results maywill give physical values which could be somewhat higher or somewhat lower than valuesunder equilibrium at normal conditions, depending upon the particular material and test. To ensure substantial equilibrium under normal con
20、ditions ofhumidity and temperature, however, will require from 20 to 100 days or more depending upon thickness and type of material and its previous history.Consequently, conditioning for reproducibility must of necessity be used for general purchase specifications and product control tests.NOTE 2Co
21、nditioning of specimens for electrical tests is also necessary to obtain consistent results. In order to secure comparative results, specimensshould be conditioned at the same temperature and humidity.4.1.2 Conditioning of specimens for electrical tests is also necessary to obtain consistent results
22、. In order to secure comparativeresults, specimens shall be conditioned at the same temperature and humidity.5. Dimensional Measurements5.1 Dimensional measurements of tube shall be made in accordance with Test Methods D668.TENSILE STRENGTH6. Significance and Use6.1 Tension tests, properly interpret
23、ed, provide information with regard to the tensile properties of rigid tubing, when employedunder conditions approximating those under which the tests are made. The It is possible that the tensile strength values maywillvary with the size of the tube and with the temperature and atmospheric conditio
24、ns. Tension tests may provide data potentiallyuseful for research and development and for engineering design, and are useful for quality control purposes.7. Apparatus7.1 Any universal testing machine may be used is acceptable for use provided it is accurate to 1 % of the lowest breaking loadto be ap
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3482013STANDARDTESTMETHODSFORRIGIDTUBESUSEDFORELECTRICALINSULATION 绝缘 刚性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511574.html