ASTM D348-2007 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电气绝缘使用刚性管的标准试验方法》.pdf
《ASTM D348-2007 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电气绝缘使用刚性管的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D348-2007 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电气绝缘使用刚性管的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 348 07An American National StandardStandard Test Methods forRigid Tubes Used for Electrical Insulation1This standard is issued under the fixed designation D 348; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods cover the
3、testing of rigid tubes usedin electrical insulation. These tubes include many types madefrom fibrous sheets of basic materials, such as cellulose, glass,or nylon, in the form of paper, woven fabrics, or mats, bondedtogether by natural or synthetic resins or by adhesives. Suchtubes include vulcanized
4、 fiber and thermosetting laminates, aswell as tubes made from cast, molded, or extruded natural orsynthetic resins, with or without fillers or reinforcing materials.1.2 Tubes tested by these test methods are most commonlycircular in cross section; however, noncircular shapes are alsoin commercial us
5、e. To the extent that the individual methodsare compatible with a particular noncircular shape, these testmethods are applicable to these other shapes. For tests onnoncircular tubes, appropriate comments should be included inthe test report, including details of orientation of test specimenswith res
6、pect to the cross section of the tube.1.3 The procedures appear in the following sections:Procedure SectionsASTM TestMethodReferenceCompressive Strength (Axial and Diametral) 12 to 17 E 4Conditioning. 4 .Density 20 to 24 .Dielectric Strength 25 to 32 D 149Dimensional Measurements 5 D 668Dissipation
7、Factor and Permittivity 33 to 35 D 150Tensile Strength 6 to 11 E 4Water Absorption 18 to 19 D 5701.4 The values stated in inch-pound units are to be regardedas the standard. SI units in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if an
8、y, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement, see 27.1.1.2. Referenced Documents2.1 ASTM Standards:2D 149
9、Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD 150 Test Methods for AC Loss Characteristics and Per-mittivity (Dielectric Constant) of Solid Electrical Insula-tionD 570 Test Method for Water Absorption of P
10、lasticsD 668 Test Methods of Measuring Dimensions of RigidRods and Tubes Used for Electrical InsulationD 1711 Terminology Relating to Electrical InsulationE4 Practices for Force Verification of Testing Machines3. Terminology3.1 Definitions For definitions of terms used in these testmethods, refer to
11、 Terminology D 1711.4. Conditioning4.1 In order to eliminate the effects of previous history ofhumidity exposure and to obtain reproducible results (Note 1),the test specimens in all cases of dispute, shall be given aconditioning treatment for physical tests (Note 2) as follows:4.1.1 Tensile Strengt
12、h, Compressive Strength (Axial andDiametral), and DensityCondition the machined specimensprior to test by drying in an air-circulating oven for 48 h at 506 3 C, followed by cooling to room temperature in adesiccator. In either case, all specimens shall be tested at roomtemperature maintained at 23 6
13、 2 C, 50 % relative humidity.NOTE 1Conditioning of specimens may be undertaken: (a) for thepurpose of bringing the material into equilibrium with standard laboratoryatmospheric conditions of 23 C and 50 % relative humidity; (b) simply toobtain reproducible results, irrespective of previous history o
14、f exposure;or (c) to subject the material to abnormal conditions of temperature orhumidity in order to predict its service behavior.The conditions given here to obtain reproducible results may givephysical values somewhat higher or somewhat lower than values underequilibrium at normal conditions, de
15、pending upon the particular materialand test. To ensure substantial equilibrium under normal conditions of1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.07 on Flexible and Rigi
16、d Insulating Materials.Current edition approved Feb. 1, 2007. Published February 2007. Originallyapproved in 1932. Last previous edition approved in 2000 as D 348 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual B
17、ook of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.humidity and t
18、emperature, however, will require from 20 to 100 days ormore depending upon thickness and type of material and its previoushistory. Consequently, conditioning for reproducibility must of necessitybe used for general purchase specifications and product control tests.NOTE 2Conditioning of specimens fo
19、r electrical tests is also neces-sary to obtain consistent results. In order to secure comparative results,specimens should be conditioned at the same temperature and humidity.5. Dimensional Measurements5.1 Dimensional measurements of tube shall be made inaccordance with Test Methods D 668.TENSILE S
20、TRENGTH6. Significance and Use6.1 Tension tests, properly interpreted, provide informationwith regard to the tensile properties of rigid tubing, whenemployed under conditions approximating those under whichthe tests are made. The tensile strength values may vary withthe size of the tube and with the
21、 temperature and atmosphericconditions. Tension tests may provide data for research anddevelopment and for engineering design, and are useful forquality control purposes.7. Apparatus7.1 Any universal testing machine may be used provided itis accurate to 1 % of the lowest breaking load to be applied.
22、Jaws that tighten under load, such as wedge-grip jaws, shall beused with the specimen properly aligned.7.2 The machine shall be verified in accordance withPractices E4.8. Test Specimens8.1 The test specimens shall be as shown in Fig. 1. Thelength, L, shall be as shown in Table 1. A groove shall bema
23、chined around the outside of the specimen at the center of itslength so that the wall section after machining shall be 60 % ofthe original nominal wall thickness. This groove shall consistof a straight section 2.25 in. (57 mm) in length with a radius of3 in. (76 mm) at each end joining it to the out
24、side diameter.Steel or brass plugs having diameters such that they will fitsnugly inside the tube, and having a length equal to the full jawlength plus 1 in. (25 mm) shall be placed in the ends of thespecimen to prevent crushing. They can be located in the tubeconveniently by separating and supporti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3482007STANDARDTESTMETHODSFORRIGIDTUBESUSEDFORELECTRICALINSULATION 电气 绝缘 使用 刚性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511573.html