1、Designation: D 2318 98 (Reapproved 2003)An American National StandardStandard Test Method forQuinoline-Insoluble (QI) Content of Tar and Pitch1This standard is issued under the fixed designation D 2318; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of thequinoline-insoluble matter (QI) in ta
3、r and pitch.1.2 Since this test method is empirical, strict adherence toall details of the procedure is necessary.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theres
4、ponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See Section 7.2. Referenced Documents2.1 ASTM Standards:2D71 Test Method for Relative Density of Solid Pitch andAsphalt (Displacemen
5、t Method)D95 Test Method for Water in Petroleum Products andBituminous Materials by DistillationD 329 Specification for AcetoneD 362 Specification for Industrial Grade Toluene3D 850 Test Method for Distillation of Industrial AromaticHydrocarbons and Related MaterialsD 4296 Practice for Sampling Pitc
6、hE1 Specification for ASTM ThermometersE11 Specification for Wire Cloth and Sieves for TestingPurposes3. Summary of Test Method3.1 The sample is digested in hot quinoline and filtered. Theinsoluble material is washed, dried, and weighed.4. Significance and Use4.1 This test method is useful in evalua
7、ting and character-izing tar and pitch, and as one element in establishing theuniformity of shipments and sources of supply.5. Apparatus5.1 Filtering Crucibles, porcelain, with fine-porosity bot-tom, 25 to 40-mL capacity, high-form, maximum pore diam-eter, 7 m.5.2 Filter ApparatusFilter flask and tu
8、be with crucibleadapter.5.3 SievesU. S. Standard 600-m (No. 30) and 250-m(No. 60), conforming to Specification E11.5.4 Electric Hot Plate or Water Bath, maintained at 75 65C.6. Reagents and Materials6.1 Quinoline, Refined, meeting the following requirements:6.1.1 The quinoline shall distill from 5 t
9、o 95 % within arange of 2C that shall include the temperature of 237.4C aftercorrections for barometric pressure and emergent stem havebeen applied. The distillation shall be carried out in accordancewith Test Method D 850 using a total immersion thermometerwith a range from 195 to 305C, graduated i
10、n 0.5C, andconforming to the requirements for Thermometer 69C asdescribed in Specification E1.6.1.2 The quinoline shall have a specific gravity at 15.5/15.5C of 1.092 to 1.098, as determined by Test Method D71,or other method of equivalent accuracy.6.1.3 The quinoline shall be clear and light in col
11、or and shallcontain less than 0.5 volume % of water as determined by TestMethod D95. If not, redistill the quinoline in all-glass appa-ratus, discarding the first 5 % and collecting the next 90 %. Ifthe quinoline contains suspended matter but is clear, light incolor, and contains less than 0.5 % wat
12、er, filter the quinolinethrough a crucible containing5gofCelite Filter Aid.6.1.4 Store the quinoline in a tightly closed, dark bottle.6.2 Toluene, Industrial Pure, meeting Specification D 362.6.3 Acetone, meeting Specification D 329.6.4 Concentrated Hydrochloric Acid.1This test method is under the j
13、urisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved Nov. 1, 2003. Published November 2003. Originallyapproved in 1964. Last previous edition ap
14、proved in 1998 as D 231898.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM Interna
15、tional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.5 Celite Analytical Filter Aid (CAFA)Dry to constantweight at 105C, and store in tightly stoppered container.6.5.1 Do not use any other grade of filter aid becausefiltration characteristics may differ. CAFA
16、 is manufacturedonly by Manville Co. and distributed through scientific supplyhouses.7. Hazards7.1 Fumes of the solvents should be removed by means ofproper hoods from all working areas. The working area shouldbe kept free of sparks and flames. Quinoline fumes should notbe inhaled, and prolonged con
17、tact with the skin should beavoided. Toluene is toxic and flammable.7.2 Observe proper laboratory procedures for handling hy-drochloric and diluting acid.8. Bulk Sampling8.1 Samples from shipments shall be taken in accordancewith Practice D 4296 and shall be free of foreign substances.Thoroughly mix
18、 the sample immediately before removing arepresentative portion for the determination or for dehydration.9. Dehydration of Sample9.1 Hard PitchIf the solid bulk sample contains freewater, air-dry a representative portion in a forced draft oven at50C.9.2 Soft PitchIf the presence of water is indicate
19、d bysurface foam on heating, maintain a representative portion ofthe bulk sample at a temperature between 125 and 150C in anopen container until the surface is free of foam. Take care notto overheat, and remove heat source immediately when foamsubsides.9.3 TarAwet tar sample may either be dehydrated
20、 or usedas received as long as conditions stated in 9.3.1 and 9.3.2 aremet.9.3.1 Dehydrate a representative portion of the bulk sampleat atmospheric pressure using a simple side-arm distillationapparatus similar to the one in Test Method D 850 and stop thedistillation when the temperature reaches 17
21、0C. Separate anyoil from the water that has distilled over (if crystals are present,warm sufficiently to ensure their solution) and thoroughly mixthe oil with the residual tar in the still after the latter has cooledto a moderate temperature.9.3.2 As an alternative to dehydration, the water content
22、ofthe tar is determined by Test Method D 95, and if the watercontent is less than 10 mass %, the QI content is corrected toa dry-tar basis (see 13.2). This alternative test method appliesonly to stable emulsions of water in tar, that is, no waterseparates when the tar sample is left undisturbed for
23、24 h atroom temperature.10. Preparation of Working Sample10.1 Hard PitchIf the pitch can be crushed at roomtemperature, prepare a 20-g working sample by suitablecrushing, mixing, and quartering of a representative portion ofthe dry sample. The crushing can be done with a small jawcrusher and a mulli
24、te mortar and pestle. No particle in therepresentative sample shall be larger than 5 mm in anydimension. Crush this sample so that all of it will pass the250-m (No. 60) sieve but will have a minimum of fineparticles. Store the sieved working sample in a tightly closedcontainer and use within 24 h (s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD231819982003STANDARDTESTMETHODFORQUINOLINEINSOLUBLEQICONTENTOFTARANDPITCH 焦油 硬沥青 喹啉 不溶物 QI 含量 标准

链接地址:http://www.mydoc123.com/p-511432.html