ASTM D2162-2013 Standard Practice for Basic Calibration of Master Viscometers and Viscosity Oil Standards《标准粘度计和粘性油标准的基本校正的标准实施规程》.pdf
《ASTM D2162-2013 Standard Practice for Basic Calibration of Master Viscometers and Viscosity Oil Standards《标准粘度计和粘性油标准的基本校正的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2162-2013 Standard Practice for Basic Calibration of Master Viscometers and Viscosity Oil Standards《标准粘度计和粘性油标准的基本校正的标准实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2162 06D2162 13Standard Practice forBasic Calibration of Master Viscometers and Viscosity OilStandards1This standard is issued under the fixed designation D2162; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This practice covers the calibr
3、ation of master viscometers and viscosity oil standards, both of which may be used to calibrateroutine viscometers as described in Test Method D445 and Specifications D446 over the temperature range from 15 to 100C.1.2 The calibration constantsvalues stated in mmSI2/s 2 units are to be regarded as t
4、he standard. The kinematic viscosities inmmstandard. No other units of measurement2/s are to be regarded as the are included in this standard.1.2.1 The SI-based units for calibration constants and kinematic viscosities are mm2/s2 and mm2/s, respectively.1.3 This standard does not purport to address
5、all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific warning statements, see Section 7.2. Referenced D
6、ocuments2.1 ASTM Standards:2D445 Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)D446 Specifications and Operating Instructions for Glass Capillary Kinematic ViscometersD1193 Specification for Reagent WaterD1250 Guide for Use of the Petrole
7、um Measurement TablesD1480 Test Method for Density and Relative Density (Specific Gravity) of Viscous Materials by Bingham PycnometerD1590 Test Method for Surface Tension of WaterE1 Specification for ASTM Liquid-in-Glass ThermometersE563 Practice for Preparation and Use of an Ice-Point Bath as a Ref
8、erence TemperatureE644 Test Methods for Testing Industrial Resistance ThermometersE1137 Specification for Industrial Platinum Resistance ThermometersE1750 Guide for Use of Water Triple Point CellsE2593 Guide for Accuracy Verification of Industrial Platinum Resistance ThermometersE2877 Guide for Digi
9、tal Contact Thermometers2.2 ISO Standard:3ISO 3666 Viscosity of Water3. Terminology3.1 Definitions:3.1.1 digital contact thermometer (DCT) , nan electronic device consisting of temperature measuring sensor in contact withthe material that provides an output to a digital display of the measured value
10、.3.1.1.1 Discussion1 This practice is under the jurisdiction ofASTM Committee D02 on Petroleum Products and Lubricants and is the direct responsibility of Subcommittee D02.07 on FlowProperties.Current edition approved May 1, 2006June 15, 2013. Published May 2006July 2013. Originally approved in 1963
11、. Last previous edition approved in 20042006 asD216299(2004).D2162 06. DOI: 10.1520/D2162-06.10.1520/D2162-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the sta
12、ndards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been mad
13、e to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A S
14、ummary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1This device consists of a temperature sensor connected to a measuring instrument; this instrument measures the temperature-de
15、pendent quantity of the sensor, computes the temperature from the measured quantity, and provides a digital output. This digitaloutput goes to a digital display and/or recording device that may be internal or external to the device. These devices are sometimesreferred to as a “digital thermometer”.N
16、OTE 1Portable electronic thermometers (PET) is an acronym sometimes used to refer to a subset of the devices covered by this definition.3.2 Definitions of Terms Specific to This Standard:3.2.1 basic calibration, ncalibration based on the primary standard, water.3.2.1.1 DiscussionPure water has a kin
17、ematic viscosity of 1.0034 mm2/s (cSt) at 20C. See ISO 3666.3.2.2 master viscometer, nglass capillary viscometer with a liquid driving head of at least 400 mm.3.2.2.1 DiscussionIt is specially designed to minimize errors due to surface tension, kinetic energy, and capillary end effects.3.2.3 viscosi
18、ty oil standard, nstable Newtonian liquid, the kinematic viscosity of which has been related to the kinematicviscosity of water through the step-up procedure described in this practice.4. Summary of Practice4.1 Two or more master viscometers, having calibration constants in the 0.001 to 0.003-mm2/s2
19、 (cSt/s) range, are calibrated withwater at 20C. The kinematic viscosities of two or more oil standards are measured at 40C in these two master viscometers.Corrections are made for buoyancy and, where necessary, for temperature and surface tension.4.2 Athird master viscometer, with a calibration con
20、stant of 0.003 to 0.009 mm2/s2 (cSt/s), , is then calibrated at 40C with thetwo standard oils and its calibration factor calculated at standard conditions for water at 20C. In like manner additional viscosityoil standards and additional master viscometers are calibrated at 40C using the average resu
21、lts from at least two masterviscometers or two oil standards. Steps between successive calibration constants or viscosities increase by a factor of three or lessuntil the desired viscosity range is covered.4.3 Oils are calibrated at other temperatures using the average result from at least two maste
22、r viscometers.5. Significance and Use5.1 Because there are surface tension or kinematic viscosity differences, or both, between the primary standard (7.4) andkinematic viscosity standards (7.5), special procedures using master viscometers are required to “step-up” from the kinematicviscosity of the
23、primary standard to the kinematic viscosities of oil standards.5.2 Using master viscometers calibrated according to this practice, an operator can calibrate kinematic viscometers inaccordance with Specifications D446.5.3 Using viscosity oil standards established in this practice, an operator can cal
24、ibrate kinematic viscometers in accordance withSpecifications D446.6. Apparatus6.1 Master Viscometers: Cannon4 or Ubbelohde5 TypeAcceptable viscometers are shown in Fig. 1 and Fig. 2. Two mastersare required with calibration constants in the 0.001 to 0.003-mm2/s2 (cSt/s) range. Additional masters ha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD21622013STANDARDPRACTICEFORBASICCALIBRATIONOFMASTERVISCOMETERSANDVISCOSITYOILSTANDARDS 标准 粘度计 粘性

链接地址:http://www.mydoc123.com/p-511114.html