ASTM D2098-2004(2012) Standard Test Method for Dynamic Water Resistance of Shoe Upper Leather by the Dow Corning Leather Tester《道康宁(Dow Corning)皮革试验器测定鞋面革抗流水性的标准试验方法》.pdf
《ASTM D2098-2004(2012) Standard Test Method for Dynamic Water Resistance of Shoe Upper Leather by the Dow Corning Leather Tester《道康宁(Dow Corning)皮革试验器测定鞋面革抗流水性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2098-2004(2012) Standard Test Method for Dynamic Water Resistance of Shoe Upper Leather by the Dow Corning Leather Tester《道康宁(Dow Corning)皮革试验器测定鞋面革抗流水性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2098 04 (Reapproved 2012)Standard Test Method forDynamic Water Resistance of Shoe Upper Leather by theDow Corning Leather Tester1This standard is issued under the fixed designation D2098; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This t
3、est method covers the determination of the dy-namic water resistance of shoe upper leather by means of theDow Corning Tester. It has been revised to show the state of theart in the equipment used in testing. It is applicable to all typesof shoe upper leather. This test method does not apply to wetbl
4、ue.1.2 Initial water penetration and water absorption can bemeasured.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standar
5、d does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM
6、 Standards:2D2099 Test Method for Dynamic Water Resistance of ShoeUpper Leather by the Maeser Water Penetration Tester3. Significance and Use3.1 This test method is intended to estimate the waterresistance of shoe upper leather. The flex imparted to theleather is a magnification of the flex given th
7、e vamp of the shoein actual wear.NOTE 1There is an indication that this test method cannot be usedinterchangeably for specification purposes with Test Method D2099.4. Apparatus4.1 Balance, sensitive to 0.01 g.4.2 Dow Corning Leather Tester,3as shown in Fig. 1,oritsequivalent. The essential features
8、of the machine are asfollows:4.2.1 A specimen holder made of two vertical clamps. Eachclamp shall have two stainless steel arms (7.5 by 0.5 by 0.5 in.(190.5 by 12.7 by 12.7 mm), one arm fixed, the othermoveable. One clamp shall be mounted on a horizontalreciprocating shaft, that is, attached by a co
9、nnecting link to amotor driven eccentric, which turns at 60 r/min. The bottom ofthe clamps shall be in the same horizontal plane. In onerotation of the eccentric, the minimum distance betweenclamps shall be 1.50 6 0.01 in. (38.16 0.25 mm) (insidemeasurement) and the maximum distance between clamps 2
10、.506 0.01 in. (63.5 6 0.25 mm) (inside measurement).4.2.2 Water Tank made of stainless steel or other noncorro-sive material. It shall be of such a size that it can be placedaround the clamps, and of such a depth that when in positionfor use, the top of the pan is at least 2.5 in. (63.5 mm) abovethe
11、 bottom of the clamps, and the bottom of the pan is at least0.5 in. (12.7 mm) below the bottom of the clamps.4.2.3 Two systems shall be used to record the number ofcycles through which the specimen is flexed. One shall be amechanical reset counter connected to the movable clamp. Theother system shal
12、l be electrical (see Fig. 2). The resistanceacross the electrodes shall be 7500 6 500 ohms. The sensingelectrode shown is inside a leather specimen filled withstainless-steel balls. The common electrode is in a salt solutionwhich is in continuous contact with the specimen duringflexing. Switch S whe
13、n manually closed starts an electricalimpulse counter actuated by a micro switch, EC, which makescontact once on each flex. This records the total number offlexes until initial water penetration. Initial water penetration is1This test method is under the jurisdiction of ASTM Committee D31 on Leather
14、and is the direct responsibility of Subcommittee D31.03 on Footwear. This testmethod was developed in cooperation with the American Leather Chemists Assn.Current edition approved Sept. 1, 2012. Published September 2012. Originallyapproved in 1962 as D209862T. Last previous edition approved in 2008 a
15、sD209804(2008). DOI: 10.1520/D2098-04R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of
16、supply of the apparatus known to the committee at this timeis Koehler Instrument Co., 1595 Sycamore Ave., Bohemia, NY 11716. Telephone:(800) 878-9070. Fax: (516) 589-3815. If you are aware of alternative suppliers,please provide this information toASTM Headquarters. Your comments will receivecareful
17、 consideration at a meeting of the responsible technical committee, whichyou may attend.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1detected by a current leakage from the high electrode throughthe specimen to the common electrode
18、in the conductingsolution. This causes the induction relay to operate, stoppingthe counter. (WarningIt is essential that the electrical circuitbe converted to 110 volts, not to exceed 28 volts across theFIG. 1 Dow Corning Leather TesterFIG. 2 Electrical Diagram for Dow Corning Leather TesterD2098 04
19、 (2012)2electrode. Specimen should be put in position or removed onlywhen the electrode circuit is not energized.)5. Reagents and Materials5.1 Magnetic Balls, stainless steel, diameter18 in. (3 mmoptional) 400 series. The steel balls must be clean and free ofgrease, oil, silicone, or rust and have a
20、 resistance less than 7500ohms before using.5.1.1 To clean, immerse stainless steel balls in mild acid,5 % Nitric. Rinse in running tap water for 3 to 5 min and allowto air dry.5.2 Rubber Gaskets or Adhesives for sealing the specimen.5.3 Magnet, to facilitate removal of the stainless steel balls.5.4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD209820042012STANDARDTESTMETHODFORDYNAMICWATERRESISTANCEOFSHOEUPPERLEATHERBYTHEDOWCORNINGLEATHERTESTER

链接地址:http://www.mydoc123.com/p-510991.html