ASTM D2070-2016 Standard Test Method for Thermal Stability of Hydraulic Oils《液压油热稳定性的标准试验方法》.pdf
《ASTM D2070-2016 Standard Test Method for Thermal Stability of Hydraulic Oils《液压油热稳定性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2070-2016 Standard Test Method for Thermal Stability of Hydraulic Oils《液压油热稳定性的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2070 16Standard Test Method forThermal Stability of Hydraulic Oils1This standard is issued under the fixed designation D2070; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pare
2、ntheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method2is designed primarily to evaluate thethermal stability of hydrocarbon based hydraulic oils althoughoxidation may occur during the t
3、est.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
4、appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D4057 Practice for Manual Sampling of Petroleum andPetroleum Products2.2 Copper Development Association Standard4UNS C11000 Electrolytic Tough P
5、itch Copper2.3 American Iron and Steel Institute Standard (AISI)5W-1 Carbon Tool Steel3. Summary of Test Method3.1 A beaker containing test oil, copper and iron rods isplaced in an aluminum block in an electric gravity convectionoven for 168 h at a test temperature of 135 C. At thecompletion of the
6、test, the copper and steel rods are ratedvisually for discoloration and the oil is analyzed for thequantity of sludge.4. Significance and Use4.1 Thermal stability characterizes physical and chemicalproperty changes which may adversely affect an oils lubricat-ing performance. This test method evaluat
7、es the thermalstability of a hydraulic oil in the presence of copper and steelat 135 C. Rod colors are the evaluation criteria. Sludge valuesare reported for informational purposes. No correlation of thetest to field service has been made.5. Apparatus5.1 An aluminum block with equally spaced holes i
8、s used.An example is described in Fig. A1.1 of Annex A1.5.2 Electric gravity convection oven capable of maintainingthe aluminum block at a test temperature of 135 C 6 1 C.5.2.1 Calibrated thermocouple and temperature indicatorcentered in aluminum block.5.3 250 mL Griffin beakers of borosilicate glas
9、s.5.4 Copper test specimens are to be UNS C11000, 99.9 %pure electrolytic tough pitch copper, 6.35 mm in diameter by7.6 cm in length (0.25 in. by 3.0 in.).6,75.5 Steel test specimens are to be AISI W-1 1 % carbonsteel, 6.35 mm in diameter 7.6 cm in length (0.25 in. by3.0 in.).6,75.6 Silicon carbide
10、abrasive 320 grit with cloth backing.5.7 Crocus cloth.5.8 41 Whatman filter paper,8,747 mm diameter.5.9 Millipore filter,9,78 m Type SC, 47 mm diameter.5.10 Millipore glass filter holder, 47 mm, Cat #XX10.04700or equivalent.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleu
11、m Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.N0 on Hydraulic Fluids.Current edition approved Dec. 15, 2016. Published January 2017. Originallyapproved in 1991. Last previous edition approved in 2010 as D2070 91(2010).DOI: 10.1520/D2070-16.2This procedu
12、re was adopted from the Fives Cincinnati Thermal Stability TestProcedure “A”, Fives Cincinnati Manual 10-SP-89050.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to th
13、e standards Document Summary page onthe ASTM website.4Available from Copper Development Assoc., Inc., 260 Madison Ave., NewYork, NY 10016, http:/www.copper.org5Available from American Iron and Steel Institute (AISI), 25 MassachusettsAve., NW, Suite 800, Washington, DC 20001, http:/www.steel.org.6The
14、 sole source of supply of the apparatus known to the committee at this timeis Metaspec LLC, 790 W. Mayfield Blvd., San Antonio, TX 78211,.7If you are aware of alternative suppliers, please provide this information toASTM International Headquarters. Your comments will receive careful consider-ation a
15、t a meeting of the responsible technical committee,1which you may attend.8The sole source of supply of the apparatus known to the committee at this timeis Whatman Ltd., part of GE Healthcare, http:/.9The sole source of supply of the apparatus known to the committee at this timeis EMD Millipore Corp.
16、, 290 Concord Rd., Billerica, MA 01821; http:/www.EMD.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with interna
17、tionally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.11 Fives Cincinnati Lubricant Heat Test Standard
18、s ColorChart.10,75.12 25 mL pipette.6. Reagents6.1 Reagent Grade Heptane(WarningFlammable.Health hazard.)6.2 Reagent Grade Acetone(WarningFlammable.Health hazard.)7. Preparation of Apparatus7.1 Handle the rods at all times using forceps or clean cottongloves.7.2 Catalyst PreparationClean the iron an
19、d copper cata-lyst rods, whether new or previously used, prior to use. Cleanthe rods with the 320 silicon carbide abrasive cloth whilerotating the rods in a drill chuck at 1700 r min to 1800 r min.Clean the surface until it has a bright copper or steel appear-ance. Discard rods when diameter is less
20、 than 6.2 mm.7.3 Prepare surface finally with a crocus cloth. Remove allgrind marks. Finish the rods to a lightly polished surface finish.7.4 Wash the rods individually with acetone and air dry oncompletion of the polishing operation.8. Procedure8.1 Place a representative 200 mL sample of test oil o
21、b-tained per D4057 sampling procedure in a clean 250 mLGriffinbeaker containing one each of the cleaned and polished ironand copper rods.8.2 Place the rods totally below the surface of the oil andcrossed. Place them in contact with each other at one pointonly.8.3 Place the beaker and its contents in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD20702016STANDARDTESTMETHODFORTHERMALSTABILITYOFHYDRAULICOILS 液压油 热稳定性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510957.html