1、Designation: D 2008 09An American National StandardStandard Test Method forUltraviolet Absorbance and Absorptivity of PetroleumProducts1This standard is issued under the fixed designation D 2008; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the measurement of the ultra-violet absorption of a variety of petro
3、leum products. It coversthe absorbance of liquids or the absorptivity of liquids andsolids, or both, at wavelengths in the region from 220 to400 nm of the spectrum.1.2 The use of this test method implies that the conditions ofmeasurementwavelength, solvent (if any), sample pathlength, and sample con
4、centrationare specified by referenceto one of the examples of the application of this test method inthe annexes or by a statement of other conditions of measure-ment.1.3 Examples of the application of this test method are thedetermination of the absorbance of white mineral oil, theabsorptivity of re
5、fined petroleum wax, and the absorptivity ofUSP petrolatum.1.4 The values stated in SI units are to be regarded as thestandard. The values stated in Fahrenheit, feet, and inches,indicated in parentheses, are for information only.1.5 WarningMercury has been designated by EPA andmany state agencies as
6、 a hazardous material that can causecentral nervous system, kidney, and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury-containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS
7、) for details and EPAs website(http:/www.epa.gov/mercury/faq.htm) for additional informa-tion. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited bystate law.1.6 This standard does not purport to address all of thesafety concerns, if a
8、ny, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see 7.3.1, 7.3.3, and 13.4.2. Referenced Documents2.1 ASTM
9、Standards:2D 1193 Specification for Reagent WaterE 131 Terminology Relating to Molecular SpectroscopyE 169 Practices for General Techniques of Ultraviolet-Visible Quantitative AnalysisE 275 Practice for Describing and Measuring Performanceof Ultraviolet and Visible Spectrophotometers3. Terminology3.
10、1 Definitions of terms and symbols relating to absorptionspectroscopy in this test method shall conform to TerminologyE 131. Terms of particular significance are the following:3.2 Definitions:3.2.1 radiant energy, nenergy transmitted as electromag-netic waves.3.2.2 radiant power, P, nthe rate at whi
11、ch energy istransported in a beam of radiant energy.3.2.3 transmittance, T, nthe molecular property of asubstance that determines its transportability of radiant power,expressed by:T 5PPo(1)where:P = the radiant power passing through the sample andPo= the radiant power incident upon the sample.3.2.4
12、 absorbance, A, nthe molecular property of a sub-stance that determines its ability to take up radiant power,expressed by:A 5 log101/T! 52log10T (2)where T is the transmittance as defined in 3.2.3.3.2.4.1 DiscussionAbsorbance expresses the excess ab-sorption over that of a specified reference or sta
13、ndard. It isimplied that compensation has been affected for reflectancelosses, solvent absorption losses, and refractive effects, if1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0F on Absor
14、ption Spectroscopic Methods.Current edition approved April 15, 2009. Published May 2009. Originallyapproved in 1962. Last previous edition approved in 2006 as D 200891(2006).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
15、Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.presen
16、t, and that attenuation by scattering is small comparedwith attenuation by absorption.3.2.5 dilution factor, f, nthe proportion of solvent increasemade to reduce the concentration and thus the absorbance of asolute, expressed by the ratio of the volume of the dilutedsolution to the volume of origina
17、l solution containing the samequantity of solute as the diluted solution.3.2.6 absorptivity, a, nthe specific property of a substanceto absorb radiant power per unit sample concentration and pathlength, expressed by:a 5 Af/bc (3)where:A = the absorbance defined in 3.2.4,f = the dilution factor defin
18、ed in 3.2.5,b = sample cell path length, andc = the quantity of absorbing substance contained in avolume of solvent.3.3 Definitions of Terms Specific to This Standard:3.3.1 sample cell pathlength, b, nthe distance in centime-tres, measured in the direction of propagation of the beam ofradiant energy
19、, between the surface of the specimen on whichthe radiant energy is incident and the surface of the specimenfrom which it is emergent.3.3.1.1 DiscussionThis distance does not include thethickness of the cell in which the specimen is contained.3.3.2 concentration, c, nthe quantity of absorbing sub-st
20、ance in grams per litre.4. Summary of Test Method4.1 The ultraviolet absorbance of a liquid is determined bymeasuring the absorption spectrum of the undiluted liquid in acell of known path length under specified conditions.4.2 The ultraviolet absorptivity of a solid or a liquid isdetermined by measu
21、ring the absorbance, at specified wave-lengths, of a solution of the liquid or solid at known concen-tration in a cell of known path length.5. Significance and Use5.1 The absorbance of liquids and the absorptivity of liquidand solids at specified wavelengths in the ultraviolet are usefulin character
22、izing petroleum products.6. Apparatus6.1 Spectrophotometer, equipped to handle liquid samplesin cells having sample path lengths up to 10 cm and capable ofmeasuring absorbance in the spectral region from 220 to400 nm with a spectral slit width of 2 nm or less. Wavelengthmeasurement shall be repeatab
23、le and known to be accuratewithin 60.2 nm or less as measured by the mercury emissionline at 313.16 nm or the absorption spectrum of either holmiumoxide glass at 287.5 nm or holmium oxide solution at 287.1nm. At the 0.4 absorbance level in the spectral region between220 and 400 nm, absorbance measur
24、ements shall be repeatablewithin 61.0 %.6.2 For recommended methods of testing spectrophotom-eters to be used in this test method, refer to Practice E 275.6.3 An instrument is considered suitable when it can beoperated in a manner to give test results equivalent to thosedescribed in 6.1.6.4 Measurem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD20082009STANDARDTESTMETHODFORULTRAVIOLETABSORBANCEANDABSORPTIVITYOFPETROLEUMPRODUCTS 石油 产品 紫外线 吸收率

链接地址:http://www.mydoc123.com/p-510837.html