ASTM D197-1987(2012) Standard Test Method for Sampling and Fineness Test of Pulverized Coal《粉煤的取样与细度的标准试验方法》.pdf
《ASTM D197-1987(2012) Standard Test Method for Sampling and Fineness Test of Pulverized Coal《粉煤的取样与细度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D197-1987(2012) Standard Test Method for Sampling and Fineness Test of Pulverized Coal《粉煤的取样与细度的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D197 87 (Reapproved 2012)Standard Test Method forSampling and Fineness Test of Pulverized Coal1This standard is issued under the fixed designation D197; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the fine-ness by sieve analysis of coal sampled from a dry pulverizingoperatio
3、n. It is not applicable to products of wet milling or tofines that have clustered into an agglomerated mass.1.2 The values stated in inch-pound units shall be regardedas the standard. Sample weights of 1000 g or less shall beexpressed in metric units.1.3 This standard does not purport to address all
4、 of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for
5、 Woven Wire Test Sieve Cloth and TestSieves3. Significance and Use3.1 This test method provides a means for assisting in theevaluation of pulverizers and pulverizer systems in terms offineness specifications. It may also be used to confirm theinfluence of coal fineness on combustion performance and
6、toevaluate carbon loss. By consent among interested parties, itmay be used for evaluation of coal fineness in preparation,pneumatic transfer systems, etc.4. Apparatus4.1 Sample ContainersHeavy vapor impervious bags,properly sealed, or noncorroding cans such as those with anairtight, friction top or
7、screw top sealed with a rubber gasketand pressure sensitive tape for use in storage and transport ofthe laboratory sample. Glass containers sealed with rubbergaskets may be used, but care must be taken to avoid breakagein transport.4.2 Drying OvenA device for passing slightly heated airover the samp
8、le. The oven should be capable of maintaining atemperature of 18 to 27F (10 to 15C) above room tempera-ture with a maximum oven temperature of 104F (40C). Airchanges should be at the rate of 1 to 4/min.4.3 Sieves, square-hole, woven-wire cloth conforming toSpecification E11:No. 8 USA Standard (2.36
9、mm)No. 16 USA Standard (1.18 mm)No. 30 USA Standard (600 m)No. 50 USA Standard (300 m)No. 100 USA Standard (150 m)No. 200 USA Standard (75 m)No. 325 USA Standard (45 m)The sieve frames shall be 8 in. (203 mm) in diameter, and theheight of the sieve from the top of the frame to the cloth shallbe eith
10、er 2 in. (50.8 mm) or 1 in. (25.4 mm). Selection ofspecific sizes is optional, depending on the objective of the test.4.3.1 Since the finer mesh sieves in particular are suscep-tible to damage by distortion resulting from undue pressure,accidental scraping with hard brushes, etc., each sieve shouldb
11、e closely inspected and discarded if it shows evidence ofdamage.4.4 Mechanical Sieving MachineThe mechanical sievingmachine shall be designed to provide both a circular motionand a tapping action. It shall be designed to accept an assemblyof vertically nested circular sieves as described in 4.3. The
12、machine action shall be such that results as described inSection 7 are obtained within the allotted time frame. Actionshall not be sufficiently severe to generate new fines by particledegradation. To facilitate the sieving operation, a controlswitch device with timer is recommended. Other equipmentd
13、esigns may be used provided the results are comparable.4.5 Balance, LaboratoryApproximately 1000-g capacity,sensitivity 0.1 g.4.6 Sampling Device (Storage System)An instrument(scoop, dipper, or other suitable device) for collecting incre-ments that will constitute the total sample.4.7 Sampling Devic
14、e (Direct-Fired System)Apparatus asdescribed in 6.2.1 and 6.2.2.1This test method is under the jurisdiction of ASTM Committee D05 on Coaland Coke and is the direct responsibility of Subcommittee D05.07 on PhysicalCharacteristics of Coal.Current edition approved Sept. 1, 2012. Published November 2012
15、. Originallypublished in 1924. Last previous edition approved in 2007 as D197 87 (2007).DOI: 10.1520/D0197-87R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the
16、 standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.8 Sample Riffle with PansA manual sample divider thatsplits the coal stream into a number of alternate elements.Riffle divisions sho
17、uld be in the size range from14 to12 in. (6.4to 12.7 mm).5. Sampling, Storage System5.1 In the pulverized coal storage system, the coal afterpulverization is conveyed into bins.5.1.1 Collection of Gross SampleCollect not less than tenincrements of representative pulverized coal preferably as it isbe
18、ing discharged from the collector. This is best accomplishedby collecting increments of not less than 50 g at regularintervals by means of a scoop, dipper, or a device capable ofremoving an increment from a specific location within thestream of pulverized coal. Place the increments in the samplecont
19、ainer and seal.5.1.2 Preparation of the Laboratory SampleA small riffle(Fig. 1) can be used for mixing and dividing the sample bysplitting. An enclosed riffle is preferred. Mix the gross sampleby splitting and recombining the halves a minimum of twotimes. Divide the sample amount by successive riffl
20、e splittingoperations on one half of the sample until the sample is dividedto approximately 500 g for the laboratory sample. To correctlyuse the riffle, the sample must be poured over the side of a pan(a third pan is necessary) and not from an end or corner, norfrom a container such as, a pail or ja
21、r. Transfer the sample toa sample container and seal.5.1.3 As an alternative to riffle mixing and splitting, thesample can be prepared as follows: Place the gross sample ona sheet of rubber, plastic, or paper and mix it by raising first onecorner of the cloth and then the other so as to roll the coa
22、l overand over at least 20 times. After mixing, divide the sample.Continue the operations of mixing and dividing until thesample is divided sufficiently so that all of one of the divisionsweighs approximately 500 g. This shall constitute the labora-tory sample.6. Sampling, Direct-Fired System6.1 In
23、the direct-fired system, the coal is pulverized anddelivered directly to the furnace in an air stream. It is difficultto obtain representative samples, as it is necessary to samplethe coal from a moving stream of coal-air mixture inside thepipe between the pulverizer and furnace. It is preferable to
24、collect such samples from vertical pipes, as in horizontal pipesa greater amount of segregation may take place.6.2 Apparatus for Sample CollectionBecause it is difficultto collect a representative sample of solids from a movingcoal-air stream, it is essential that the equipment and samplingprocedure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD19719872012STANDARDTESTMETHODFORSAMPLINGANDFINENESSTESTOFPULVERIZEDCOAL 粉煤 取样 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510732.html