ASTM D1857 D1857M-2004(2010) Standard Test Method for Fusibility of Coal and Coke Ash《煤和焦炭灰的可溶性标准试验方法》.pdf
《ASTM D1857 D1857M-2004(2010) Standard Test Method for Fusibility of Coal and Coke Ash《煤和焦炭灰的可溶性标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1857 D1857M-2004(2010) Standard Test Method for Fusibility of Coal and Coke Ash《煤和焦炭灰的可溶性标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1857/D1857M 04 (Reapproved 2010)Standard Test Method forFusibility of Coal and Coke Ash1This standard is issued under the fixed designation D1857/D1857M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the observation
3、of the tempera-tures at which triangular pyramids (cones) prepared from coaland coke ash attain and pass through certain defined stages offusing and flow when heated at a specified rate in controlled,mildly reducing, and where desired, oxidizing atmospheres.1.2 The test method is empirical, and stri
4、ct observance ofthe requirements and conditions is necessary to obtain repro-ducible temperatures and enable different laboratories to obtainconcordant results.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may n
5、ot be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibili
6、ty of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2013 Practice for Preparing Coal Samples for AnalysisD3174 Test Method for Ash in the Analysis Sam
7、ple of Coaland Coke from Coal3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 The critical temperature points to be observed are asfollows, denoting the atmosphere used:3.1.2 fluid temperature, FTthe temperature at which thefused mass has spread out in a nearly flat layer with
8、amaximum height of 1.6 mm 116 in. as shown by the fifthcone, FT, in Fig. 1.3.1.3 hemispherical temperature, HTthe temperature atwhich the cone has fused down to a hemispherical lump atwhich point the height is one half the width of the base asshown by the fourth cone, HT, in Fig. 1.3.1.4 initial def
9、ormation temperature, ITthe temperatureat which the first rounding of the apex of the cone occurs.Shrinkage or warping of the cone ignored if the tip remainssharp. In Fig. 1, the first cone shown is an unheated one; thesecond cone IT is a typical cone at the initial deformation stage.3.1.5 softening
10、 temperature, STthe temperature at whichthe cone has fused down to a spherical lump in which theheight is equal to the width at the base as shown by the thirdcone, ST, in Fig. 1.4. Significance and Use4.1 Design of most coal combustion and coal conversionequipment anticipates that the ash either rem
11、ain solid orassume some degree of fluidity, depending on the particulardesign.Ash fusibility temperatures predict whether the ash willperform properly in the process for which the coal was chosen.5. Apparatus and Materials5.1 FurnaceAny gas-fired or electric furnace conformingto the following requir
12、ements may be used:5.1.1 Capable of maintaining a uniform temperature zone inwhich to heat the ash cones. This zone shall be such that thedifference in the melting point of 12.7-mm 12-in. pieces ofpure gold wire when mounted in place of the ash cones on thecone support shall be not greater than 11C
13、20F in areducing atmosphere test run.5.1.2 Capable of maintaining the desired atmosphere sur-rounding the cones during heating. The composition of theatmosphere, reducing or oxidizing, shall be maintained withinthe limits specified in Section 6. The desired atmosphere in thegas-fired furnace surroun
14、ding the cones shall be obtained byregulation of the ratio of gas to air in the combustion mixture.The desired atmosphere in the electric furnace shall be ob-tained by means of gases introduced into the heating chamber.1This test method is under the jurisdiction of ASTM Committee D05 on Coaland Coke
15、 and is the direct responsibility of D05.21 on Methods of Analysis.Current edition approved Sept. 1, 2010. Published November 2010. Originallyapproved 1961. Last previous edition approved 2004 as D1857 04. DOI: 10.1520/D1857-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
16、 orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.The muffle shal
17、l be gas impervious, free from cracks, and theclosure plug tight-fitting. The gas supply tube shall be sealed tothe back wall of the preheating chamber and shall not extend tothe front of the preheating chamber against the perforatedbaffle.5.1.3 Capable of regulation so that the rate of temperaturer
18、ise shall be 8 6 3C 15 6 5F/min.5.1.4 Providing means of observing the ash cones during theheating. Observation on the same horizontal plane as thecone-support surface shall be possible.5.2 Cone MoldA commercially available cone mold asshown in Fig. 2. The cone shall be 19 mm 34 in. in height and6.4
19、 mm 14 in. in width at each side of the base which is anequilateral triangle. A steel spatula with a pointed tip, groundoff to fit the cone depression in the mold, is suitable forremoval of the ash cone.5.3 Optical Pyrometer or Thermocouple, for temperaturemeasurements, conforming to the following r
20、equirements:5.3.1 Optical PyrometerAn optical pyrometer of the dis-appearing filament type shall be used. The instrument shallhave been calibrated to be accurate within 11C 20F up to1400C 2550F and within 16C 30F from 1400 to 1600C2550 to 2900F (Note 1). The pyrometer filament shall besighted on the
21、 cones until the softening point temperature C(Fig. 1) has been passed, and then sighted on the cone support.The pyrometer shall have readable graduations not larger than5.5C 10F.NOTE 1The pyrometer equipment shall be standardized periodicallyby a suitably equipped standardizing laboratory such as t
22、hat of theNational Bureau of Standards, or checked periodically against equipmentcertified by the Bureau of Standards.5.3.2 ThermocoupleA thermocouple of platinum andplatinum-rhodium, protected from the furnace gases by aglazed porcelain sheath, shall be used with a high-resistancemillivoltmeter or
23、potentiometer accurate and readable to within5.5C 10F. The sheath shall be sealed to the furnace wall byalundum cement. The hot junction of the thermocouple shalltouch the end of the sheath and shall be located in the center ofthe muffle and immediately to the rear of the cones. Thethermocouple prot
24、ective sheath shall be checked periodicallyfor cracks. The thermocouple and its meter shall meet therequirements of Section 9. The potentiometer or millivoltmetershall be so located or adequately shielded as to prevent radiantand convection heating of the cold junction. The room tem-perature compens
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD1857D1857M20042010STANDARDTESTMETHODFORFUSIBILITYOFCOALANDCOKEASH 焦炭 可溶性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510577.html