《ASTM D1748-2010 Standard Test Method for Rust Protection by Metal Preservatives in the Humidity Cabinet《在湿润箱中用金属保护剂防止金属生锈的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1748-2010 Standard Test Method for Rust Protection by Metal Preservatives in the Humidity Cabinet《在湿润箱中用金属保护剂防止金属生锈的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1748 10Designation: 366/84Standard Test Method forRust Protection by Metal Preservatives in the HumidityCabinet1This standard is issued under the fixed designation D1748; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method cover
3、s the evaluation of the rust-preventive properties of metal preservatives under conditionsof high humidity.1.2 The values stated in SI units are to be regarded as thestandard except where the test apparatus or consumable partsare only available in other units. In such cases these will beregarded as
4、standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to consult andestablish appropriate safety and health practices and deter-m
5、ine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A109/A109M Specification for Steel, Strip, Carbon (0.25Maximum Percent), Cold-RolledD512 Test Methods for Chloride Ion In WaterD516 Test Method for Sulfate Ion in WaterE11 Specification for Woven
6、Wire Test Sieve Cloth and TestSievesE323 Specification for Perforated-Plate Sieves for TestingPurposes2.2 Federal Standards:3QQ-S-698 Steel Sheet and Strip, Low Carbon2.3 Military Standards:4MIL-C-5646F Cloth, AirplaneMIL-C-15074E Corrosive Preventive Compound FingerPrint Remover2.4 Society of Autom
7、otive Engineers:5SAE 1009C Tee Reducer, Bulkhead on Side, Flareless Tube3. Summary of Test Method3.1 Steel panels are prepared to a prescribed surface finish,dipped in the test oil, allowed to drain, and then suspended ina humidity cabinet at 48.9C (120F) for a specified number ofhours. The oil fail
8、s or passes the test in accordance with thesize and number of rust dots on the test surfaces of the panels.4. Significance and Use4.1 This test method is used for measuring the relativeabilities of metal preservatives to prevent the rusting of steelpanels under conditions of high humidity. It should
9、 not berelied upon to predict the effectiveness of a metal preservativein which high humidity is not the principal factor in the rusting.4.2 Comparisons made by this test method should normallybe limited to similar metal preservative combinations designedfor similar applications. The test life requi
10、red for each type ofmetal preservative and for each intended application should bebased on actual experience with that type of preservative in theintended service.4.3 Since the precision of the test method appears to be lessthan desired, a number of repeat tests may be necessary toestablish the test
11、 life of a given metal preservative, and repeattests by this test method in more than one cabinet aresometimes desirable.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.L0.03 on Corrosion Testin
12、g of Sheet Fluids Metal Processing Fluids.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1960. Last previous edition approved in 2008 as D174802(2008).DOI: 10.1520/D1748-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cus
13、tomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Superintendent of Documents, U.S. Government PrintingOffice, Washington, DC 20402.4Available from Standardization Documents Order Des
14、k, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.5Available from Society of Automotive Engineers, 400 Commonwealth Dr.,Warrendale, PA 15096.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
15、700, West Conshohocken, PA 19428-2959, United States.4.4 The data obtained from this accelerated test is of interestonly in eliminating the most unsuitable materials or forindicating a probable relative order of protection against rustunder conditions of high humidity. This test method does notpresc
16、ribe the exposure periods to be used for a specific product,nor the interpretation to be given to the results.5. Apparatus5.1 The apparatus shall conform to the details shown in theAnnex A1.6. Panel Cleaning Materials6.1 Aluminum Oxide Cloth, 240-grit.NOTE 1Paper-backed abrasives, wet or dry, waterp
17、roof, or iron oxideabrasives are prohibited.6.2 Silica Sand, white, dry, sharp, chloride free, or alumi-num oxide, blasting grade. (The size shall be such that it meetsthe following sieve requirements of Specifications E11 andE323.6.2.1 One hundred percent must pass through a No. 10(2.00-mm) sieve.6
18、.2.2 Minimum of 90 % must pass through a No. 20(850-m) sieve.6.2.3 Maximum of 10 % permitted to pass through a No. 50(300-m) sieve.6.3 CleanersSelect a cleaning media and method, whichis safe, non-film forming and which does not in any way attackor etch the surface chemically. In addition, no Class
19、1 ozonedepleting substances conforming to Section 602(a) of the CleanAir Act Amendments of 1990 (42USC7671a) as identified inSection 326 of PL 102-484 should be used. Use a procedure asoutlined in Test Method F22 to judge the merit of the selectedcleaning technique.NOTE 2A typical solvent found acce
20、ptable for this purpose is hexaneor Stoddard solvent.NOTE 3The original precision was developed using a combination ofpetroleum naphtha and methanol. These are no longer used due to toxicityissues.6.4 Gauze, lint free cotton or gauze pads.7. Humidity Cabinet Operating Conditions7.1 During evaluation
21、 of a sample the cabinet shall be runcontinuously with the following standard conditions beingmaintained:Air temperature:Inside the cabinet 48.9 6 1.1C (120 6 2.0F)Outside the cabinet 24.1 6 5.5C (75.4 6 10.0F)Rate of air to the cabinet0.878 6 0.028 m3/h(31.0 6 1ft3/h) at 25.0C and760 mm HgWater in
22、cabinet:Level 203.0 6 6.4mm(8.0614 in.)pH 5.5 to 7.5Oil content clear with no evidence of oilChlorides less than 20 ppm (Test MethodsD512)Sulfates and sulfitesAless than 20 ppm as sulfate (TestMethod D516)Speed of rotating 0.33 6 0.03 rpmCover close fittingCloth layers in cover shall not be torn, co
23、ntaminated,nor contain droplets of waterCover opening to a height of 355 mm (14 in.) atthe frontABoil the water sample with 10 mL of saturated bromine water before makingthe test for sulfates.7.2 Rate of air to the cabinet, air temperature, pH, and waterlevel shall be checked and regulated if necess
24、ary twice eachday, at 7- to 8-h intervals. Remaining standard conditions shallbe closely checked once each week. The pH measurement maybe made with wide-range indicator paper.NOTE 4Values for pH outside the limits shown indicate contamina-tion that should be investigated and corrected. A persistent
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD17482010STANDARDTESTMETHODFORRUSTPROTECTIONBYMETALPRESERVATIVESINTHEHUMIDITYCABINET 湿润 中用 金属 保护

链接地址:http://www.mydoc123.com/p-510401.html