1、Designation: D1665 98 (Reapproved 2009)Standard Test Method forEngler Specific Viscosity of Tar Products1This standard is issued under the fixed designation D1665; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of specificviscosity of tars and their fluid products. It does not determineabsolut
3、e viscosity, but is an empirical flow test. Only byconforming strictly to requirements of the test method arereproducible results obtained.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to
4、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D140 Prac
5、tice for Sampling Bituminous MaterialsE1 Specification for ASTM Liquid-in-Glass ThermometersE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 Definitions:3.1.1 Engler specific viscositythe ratio obtained by divid-ing the time of flow, in s, of 50 mL of material using
6、an Englerviscosimeter at a selected temperature by a factor representingthe time of flow, in s, for an equal volume of water at 25C. Theusual temperatures for determination of specific viscosity of tarmaterials are 25C, 40C, 50C, and 100C, and generally thetemperature is so selected that the specifi
7、c viscosity is not morethan 45.4. Summary of Test Method4.1 The time, in s, is measured for a fixed volume of liquidmaterial to flow through an efflux tube under an accuratelyreproducible head and at a closely controlled temperature. TheEngler specific viscosity is then calculated by dividing theeff
8、lux time by the viscometer calibration factor as determinedby making the same efflux measurement for water.5. Significance and Use5.1 This test method is useful in characterizing the consis-tency of tar and tar distillates by measuring their flow proper-ties. It is applicable to materials that are r
9、eadily liquid attemperatures up to 100C.6. Apparatus6.1 Engler Viscosimeter as shown in Fig. 1, consisting ofthe following:6.1.1 CupThis is a gold-plated cylindrical brass vessel of106.0 6 1.0 mm, A, inside diameter, closed at the top by adouble walled lid. To the rounded bottom is attached ametal-e
10、ncased tapered platinum efflux tube 20.0 6 0.1 mm, H,long with an inside diameter of 2.90 6 0.02 mm, E, at the topand 2.80 6 0.02 mm, F, at the bottom. The efflux tube shallproject through and extend 3.0 6 0.2 mm, G, below a jacketthat surrounds the cup and shall have a bottom outsidediameter, inclu
11、ding its surrounding metal, of 4.5 6 0.2 mm, I.Three metal measuring points, spaced equidistantly around thecircumference of the cup, are fastened to the sides and extendinwardly approximately 7 mm, then turn up at a right angle andend in sharp points which are located 52.0 6 0.5 mm, D,vertically ab
12、ove the lower end of the efflux tube and 25.0 6 1.0mm, C, above the lowest portion of the cylindrical sidewall ofthe cup. They serve both for indicating when the instrument islevel and for measuring the charge of material, which isapproximately 250 mL.1This test method is under the jurisdiction of A
13、STM Committee D04 on Roadand Paving Materials and is the direct responsibility of Subcommittee D04.43 onSpecifications and Test for Tar and Tar Products.Current edition approved Dec. 1, 2009. Published January 2010. Originallyapproved in 1959. Previous edition approved in 2003 as D1665 98 (2003). DO
14、I:10.1520/D1665-98R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr
15、 Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.2 JacketThe cup is surrounded by a jacket whichholds water or other suitable liquid serving as a constanttemperature bath. In the type illustrated, the jacket is providedwith a thermometer clamp and stirring device. A tr
16、ipodsupports the apparatus and also carries a ring burner by meansof which the bath is heated. Adjustable legs on the tripod serveto level the instrument. Other arrangements of outer baths,supports, and stirring devices are acceptable, especially when itis desired to use more than one standardized c
17、up in a singlebath.6.1.3 StopperThe efflux tube in the cup is closed oropened by the insertion or withdrawal of a tapered hardwoodstopper which, to leave the tube open, can be suspended by itsbrass pin from the hook on the cover. The stopper shall be asmooth, round, wooden rod 180 mm long and 8 mm i
18、ndiameter, with a brass wire pin 20 mm and 1.83 mm indiameter long inserted diametrically through the rod at a point50 mm from the lower end, and tapered uniformly below thispin to end in a circular plane 1.6 to 2.0 mm in diameter. Abovethe pin the rod shall be planed or grooved on four sides to ade
19、pth of 1 mm to prevent any possible restriction of air flow.6.2 ReceiversTwo types are required as follows:6.2.1 Testing Flask50 mLgraduate calibrated at 20C (seeFig. 2).6.2.2 Calibration FlaskFor standardization purposesthere shall be available a Kohlrausch flask, Fig. 3, with topFIG. 1 Engler Visc
20、osimeterD1665 98 (2009)2enlarged above the graduation mark and calibrated to contain200 6 0.1 mL at 20C.6.3 ThermometersASTM Engler Viscosity Thermometers23C, 24C, and 25C as required, and conforming to therequirements for these thermometers as specified in Specifica-tion E1.6.4 TimerStop watch or o
21、ther timing device graduated indivisions of 0.2 s or less, and accurate to within 0.1 % whentested over a 60-min period.6.5 Strainer300 mm ASTM sieve conforming to Specifi-cation E11.7. Sampling7.1 Samples from shipments or production vessels shall betaken in accordance with Practice D140 and shall
22、be free offoreign substances. Thoroughly heat and stir the sample beforeremoving a representative portion for the determination.8. Preparation of Sample8.1 Stir the sample until it is homogeneous, using heat ifnecessary. Avoid inclusion of air bubbles, loss of volatile orother effects, which may inf
23、luence the viscosity. Strain arepresentative portion of the sample through the strainer toeliminate particles, and proceed in accordance with Section 10.Strain the material directly into the viscosimeter if preferred.9. Standardization and Calibration of Viscosimeter9.1 The efflux time for 200 mL of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD166519982009STANDARDTESTMETHODFORENGLERSPECIFICVISCOSITYOFTARPRODUCTS 柏油 制品 粘度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510262.html