ASTM D1618-2017 Standard Test Method for Carbon Black Extractables&x2014 Transmittance of Toluene Extract《可萃取炭黑甲苯萃取物透光率的标准试验方法》.pdf
《ASTM D1618-2017 Standard Test Method for Carbon Black Extractables&x2014 Transmittance of Toluene Extract《可萃取炭黑甲苯萃取物透光率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1618-2017 Standard Test Method for Carbon Black Extractables&x2014 Transmittance of Toluene Extract《可萃取炭黑甲苯萃取物透光率的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1618 99 (Reapproved 2011)D1618 17Standard Test Method forCarbon Black ExtractablesTransmittance of TolueneExtract1This standard is issued under the fixed designation D1618; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the degree of toluene discoloration by carbon black extract
3、ables and is usefulin controlling the reaction processes for production of carbon black. This test method may not be applicable to carbon blacks withhigh extractables.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 Thi
4、s standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health and healthenvironmental practices and determine theapplicability of regulatory limitations prior to
5、use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers t
6、o Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1799 Practice for Carbon BlackSampling Packaged ShipmentsD1900 Practice for Carbon BlackSampling Bulk ShipmentsD4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing Industries
7、3. Terminology3.1 Definitions:3.1.1 carbon black toluene discoloration, n the transmittance, at 425 nm, of the filtrate obtained from the toluene extract ofcarbon black, compared to that of pure toluene.4. Significance and Use4.1 The toluene discoloration value provides an estimate of toluene-solubl
8、e discoloring residues present on the carbon black.5. Apparatus and Reagent5.1 Spectrophotometer, with tungsten filament lamp, 20-nm maximum spectral bandpass, capable of measuring percenttransmittance at a 425-nm wavelength. The instrument is to be operated in accordance with the manufacturers dire
9、ctions foroptimum performance.5.2 Cuvets, rectangular, with an optical light path of 10 mm.5.3 Balance, analytical, with a sensitivity of 60.01 g.5.4 Oven, gravity-convection type, capable temperature regulation within 61C at 125C and temperature uniformity within65C.5.5 Pipet, automatic, bottle-typ
10、e, 20 cm3, with a repeatability of 60.1.1 This test method is under the jurisdiction of ASTM Committee D24 on Carbon Black and is the direct responsibility of Subcommittee D24.31 on Non-Carbon BlackComponents of Carbon Black.Current edition approved May 1, 2011Aug. 1, 2017. Published July 2011August
11、 2017. Originally approved in 1965. Last previous edition approved in 20042011 asD1618 99 (2004).(2011). DOI: 10.1520/D1618-99R11.10.1520/D1618-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standard
12、svolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to
13、adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consh
14、ohocken, PA 19428-2959. United States15.6 Erlenmeyer Flasks, 125 cm3 with ground-glass stopper.5.7 Filter Paper, qualitative grade, medium retention, medium-fast filter speed, 150-mm diameter.5.8 Glass Filtering Funnels, 75-mm inside diameter at the top.5.9 Beakers, 50 or 100 cm3, with pouring lips.
15、5.10 Wiping Paper, lint-free.5.11 Cotton Swabs.5.12 Fume Hood, fully enclosed on three sides, with spark-proof fan and motor.5.13 Toluene, analytical reagent grade.6. Sampling6.1 Samples shall be taken in accordance with Practice D1799 or Practice D1900.7. Standardization of Apparatus7.1 Turn on the
16、 spectrophotometer and allow it to warm for the length of time specified by the manufacturer.7.2 Check the zero reading of the spectrophotometer in accordance with the manufacturers instructions, and adjust if necessary.7.3 Place the funnel with the filter paper into an Erlenmeyer flask. Filter appr
17、oximately 30 cm3 of toluene into the flask andstopper the flask.7.4 Pour a portion of the toluene into the beaker with the pouring lip for simplifying the transfer of the toluene to the cuvet.7.5 Rinse the cuvet with the filtered toluene three times, filling approximately one third full each time. D
18、iscard this rinsingtoluene into an approved safety container.NOTE 1The cuvet must be handled on the ground-glass sides only. Do not touch the smooth, clear sides with the fingers.7.6 Fill the cuvet and wipe the outside surfaces with the lint-free wiping paper while holding the cuvet in front of a su
19、itablelight source. The toluene must be free of any contaminants, such as lint particles, which might cause light scattering, thusinfluencing the test results. If necessary, rewipe the outside until perfectly clean, or clean the inside surfaces with a cotton swab.Repeat 7.5 if the inside surfaces ar
20、e cleaned.7.7 . Insert the cuvet into the spectrophotometer and adjust it to read 100 % transmittance at the 425-nm wavelength.8. Procedure8.1 Dry an adequate sample of carbon black at 125 6 1C for 60, +5, 0 min, using a gravity-convection oven.NOTE 2An infrared lamp must not be used for drying samp
21、les, as it will vaporize some of the extractable materials.8.2 Allow the sample to cool to room temperature in a desiccator.8.3 Weigh 2.00 6 0.01 g of the carbon black and transfer it to a 125-cm3 Erlenmeyer flask with ground-glass stopper.8.4 Add 20 cm3 of toluene to the sample flask and stopper th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD16182017STANDARDTESTMETHODFORCARBONBLACKEXTRACTABLESX2014TRANSMITTANCEOFTOLUENEEXTRACT 萃取 炭黑 甲苯

链接地址:http://www.mydoc123.com/p-510163.html