ASTM D1557-2009 Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56 000 ft-lbf ft3 (2 700 kN-m m3))《用修正作用力56000 ft-Ibf ft(2700 KN-m m3.pdf
《ASTM D1557-2009 Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56 000 ft-lbf ft3 (2 700 kN-m m3))《用修正作用力56000 ft-Ibf ft(2700 KN-m m3.pdf》由会员分享,可在线阅读,更多相关《ASTM D1557-2009 Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56 000 ft-lbf ft3 (2 700 kN-m m3))《用修正作用力56000 ft-Ibf ft(2700 KN-m m3.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1557 09Standard Test Methods forLaboratory Compaction Characteristics of Soil UsingModified Effort (56,000 ft-lbf/ft3(2,700 kN-m/m3)1This standard is issued under the fixed designation D1557; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 T
3、hese test methods cover laboratory compaction meth-ods used to determine the relationship between molding watercontent and dry unit weight of soils (compaction curve)compacted in a 4- or 6-in. (101.6- or 152.4-mm) diameter moldwith a 10.00-lbf. (44.48-N) rammer dropped from a height of18.00 in. (457
4、.2 mm) producing a compactive effort of 56 000ft-lbf/ft3(2700 kN-m/m3).NOTE 1The equipment and procedures are the same as proposed bythe U.S. Corps of Engineers in 1945. The modified effort test (see 3.1.2)is sometimes referred to as the Modified Proctor Compaction Test.1.1.1 Soils and soil-aggregat
5、e mixtures are to be regarded asnatural occurring fine- or coarse-grained soils, or composites ormixtures of natural soils, or mixtures of natural and processedsoils or aggregates such as gravel or crushed rock. Hereafterreferred to as either soil or material.1.2 These test methods apply only to soi
6、ls (materials) thathave 30 % or less by mass of their particles retained on the34-in. (19.0-mm) sieve and have not been previously com-pacted in the laboratory; that is, do not reuse compacted soil.1.2.1 For relationships between unit weights and moldingwater contents of soils with 30 % or less by w
7、eight of materialretained on the34-in. (19.0-mm) sieve to unit weights andmolding water contents of the fraction passing the34-in.(19.0-mm) sieve, see Practice D4718.1.3 Three alternative methods are provided. The methodused shall be as indicated in the specification for the materialbeing tested. If
8、 no method is specified, the choice should bebased on the material gradation.1.3.1 Method A:1.3.1.1 Mold4-in. (101.6-mm) diameter.1.3.1.2 MaterialPassing No. 4 (4.75-mm) sieve.1.3.1.3 LayersFive.1.3.1.4 Blows per layer25.1.3.1.5 UsageMay be used if 25 % or less by mass of thematerial is retained on
9、the No. 4 (4.75-mm) sieve. However, if5 to 25 % by mass of the material is retained on the No. 4(4.75-mm) sieve, Method A can be used but oversize correc-tions will be required (See 1.4) and there are no advantages tousing Method A in this case.1.3.1.6 Other UseIf this gradation requirement cannot b
10、emet, then Methods B or C may be used.1.3.2 Method B:1.3.2.1 Mold4-in. (101.6-mm) diameter.1.3.2.2 MaterialPassing38-in. (9.5-mm) sieve.1.3.2.3 LayersFive.1.3.2.4 Blows per layer25.1.3.2.5 UsageMay be used if 25 % or less by mass of thematerial is retained on the38-in. (9.5-mm) sieve. However, if5 t
11、o 25 % of the material is retained on the38-in. (9.5-mm)sieve, Method B can be used but oversize corrections will berequired (See 1.4). In this case, the only advantages to usingMethod B rather than Method C are that a smaller amount ofsample is needed and the smaller mold is easier to use.1.3.2.6 O
12、ther UsageIf this gradation requirement cannotbe met, then Method C may be used.1.3.3 Method C:1.3.3.1 Mold6-in. (152.4-mm) diameter.1.3.3.2 MaterialPassing34-in. (19.0-mm) sieve.1.3.3.3 LayersFive.1.3.3.4 Blows per layer56.1.3.3.5 UsageMay be used if 30 % or less (see 1.4)bymass of the material is
13、retained on the34-in. (19.0-mm) sieve.1.3.4 The 6-in. (152.4-mm) diameter mold shall not be usedwith Method A or B.NOTE 2Results have been found to vary slightly when a material istested at the same compactive effort in different size molds, with thesmaller mold size typically yielding larger values
14、 of unit weight anddensity (1).21.4 If the test specimen contains more than 5 % by mass ofoversize fraction (coarse fraction) and the material will not be1These test methods are under the jurisdiction of ASTM Committee D18 on Soiland Rock and are the direct responsibility of Subcommittee D18.03 on T
15、exture,Plasticity and Density Characteristics of Soils.Current edition approved Oct. 1, 2009. Published October 2009. Originallyapproved in 1958. Last previous edition approved in 2007 as D1557 07. DOI:10.1520/D1557-09.2The boldface numbers in parentheses refer to the list of references at the end o
16、fthis standard.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.included in the test, corrections must be made to the unitweight and molding water content of the test s
17、pecimen or to theappropriate field in-place unit weight (or density) test specimenusing Practice D4718.1.5 This test method will generally produce a well-definedmaximum dry unit weight for non-free draining soils. If thistest method is used for free-draining soils the maximum unitweight may not be w
18、ell defined, and can be less than obtainedusing Test Methods D4253.1.6 All observed and calculated values shall conform to theguidelines for significant digits and rounding established inPractice D6026, unless superseded by these test methods.1.6.1 For purposes of comparing measured or calculatedval
19、ue(s) with specified limits, the measured or calculatedvalue(s) shall be rounded to the nearest decimal or significantdigits in the specified limits.1.6.2 The procedures used to specify how data are collected/recorded or calculated in this standard are regarded as theindustry standard. In addition,
20、they are representative of thesignificant digits that generally should be retained. The proce-dures used do not consider material variation, purpose forobtaining the data, special purpose studies, or any consider-ations for the users objectives; it is common practice toincrease or reduce significant
21、 digits of reported data to becommensurate with these considerations. It is beyond the scopeof these test methods to consider significant digits used inanalytical methods for engineering design.1.7 The values in inch-pound units are to be regarded as thestandard. The values stated in SI units are pr
22、ovided forinformation only, except for units of mass. The units for massare given in SI units only, g or kg.1.7.1 It is common practice in the engineering profession toconcurrently use pounds to represent both a unit of mass (lbm)and a force (lbf). This implicitly combines two separatesystems of uni
23、ts; that is, the absolute system and the gravita-tional system. It is scientifically undesirable to combine the useof two separate sets of inch-pound units within a singlestandard. These test methods have been written using thegravitational system of units when dealing with the inch-poundsystem. In
24、this system, the pound (lbf) represents a unit of force(weight). However, the use of balances or scales recordingpounds of mass (lbm) or the recording of density in lbm/ft3shall not be regarded as a nonconformance with this standard.1.8 This standard does not purport to address all of thesafety conc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15572009STANDARDTESTMETHODSFORLABORATORYCOMPACTIONCHARACTERISTICSOFSOILUSINGMODIFIEDEFFORT56000FTLBFFT32700KNMM3

链接地址:http://www.mydoc123.com/p-510030.html