ASTM D1545-2013 Standard Test Method for Viscosity of Transparent Liquids by Bubble Time Method《用起泡时间法测定透明液体粘度的标准试验方法》.pdf
《ASTM D1545-2013 Standard Test Method for Viscosity of Transparent Liquids by Bubble Time Method《用起泡时间法测定透明液体粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1545-2013 Standard Test Method for Viscosity of Transparent Liquids by Bubble Time Method《用起泡时间法测定透明液体粘度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1545 07 (Reapproved 2012) D1545 13Standard Test Method forViscosity of Transparent Liquids by Bubble Time Method1This standard is issued under the fixed designation D1545; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method cover
3、s the determination of the viscosity in bubble seconds by timing. The bubble seconds areapproximately equal to stokes for most liquids.1.2 The test method is applicable to transparent liquids that are free from crystalline or gel particles.1.3 The values stated in SI units are to be regarded as stan
4、dard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the app
5、licability of regulatorylimitations prior to use.2. Terminology2.1 Definitions:2.1.1 viscosity, nthe resistance experienced by one portion of a liquid moving over another portion of the liquid. The absoluteunit of viscosity in the cgs, centimeter-gram-second, system is the poise which is expressed a
6、s dyne-seconds per square centimetre.Stokes are equal to poises divided by density. The absolute SI, International System of Units (metric system), viscosity unit is thepascal-second.3. Apparatus3.1 Constant-Temperature BathAny suitable bath capable of maintaining temperature at 25 6 0.1C with water
7、 as the bathmedium.3.2 Standard Viscosity Tubes of clear glass and with flat bottoms, 10.65 6 0.025 mm in inside diameter; 114 6 1 mm in outsidelength. Plainly legible lines shall be located as follows (Note 1):1 This test method is under the jurisdiction of ASTM Committee D01 on Paint and Related C
8、oatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.24 on Physical Properties of Liquid Paints heavy series, 14 tubesmarked 10 to 200; and very heavy series, 7 tubes, marked 250 to 1000.3.4 Timing DeviceStopwatch or electric stop clock capable of being read to a
9、precision of 0.1 s.3.5 Tube Racks, capable of inverting one or more viscosity tubes 180 to within 1 of a vertical position while rack and tubesare immersed in the constant temperature bath.3.6 Viscosity Tube Corks, No. 2 short.4. Procedure4.1 Fill a standard viscosity tube with the material to be te
10、sted to approximately level with the 108-mm line.4.2 Transfer the tube to a constant 25C temperature bath with the cork loosely inserted. Hold at this temperature for 10 min.NOTE 2Adequate control of the temperature bath is essential. A variation of 0.1C in the temperature of the bath will cause a 1
11、 % variation in thetimed bubble travel.4.3 At the end of 10 min adjust the level of the liquid so that the bottom meniscus will be level with the 100-mm line. Insertthe cork so that the bottom of the cork is on the level with the 108-mm line. This will ensure a bubble of suitable and uniformsize.4.4
12、 Insert the tube in the rack and immerse in the 25C water bath. Allow the tube(s) to stand with cork down in the bath aminimum of 20 min before determining the viscosity.NOTE 3For viscosities of liquids that have a timed bubble travel of 4 s or less, more precise results can be obtained by compariso
13、n against referencestandards having a predetermined viscosity or timed bubble travel.4.5 To read, invert the tube quickly and determine the time required for the bubble to rise in seconds. When determining thetime in seconds start the timing device when the top of the bubble becomes tangent to the 2
14、7-mm line on the tube. Stop the timingwhen the top of the bubble becomes tangent with the 100-mm line. This gives a 73-mm timed bubble travel. All timings shall bemade with the tube in an exact vertical position.NOTE 4Positioning of the tube in a vertical position is mandatory. A tube one radius off
15、 the vertical will give an error of approximately 10 % in thetime of bubble travel.5. Report5.1 Report the following information:5.1.1 The viscosity obtained by the timing method expressed as “bubble seconds” or “approximate stokes.”NOTE 5The time in seconds or “bubble seconds” is an approximate mea
16、surement of stokes when the bubble time method is applied to most rawmaterials and finished products encountered by the paint, varnish, and lacquer industries. This relationship does not hold for silicones or water dispersionsof gums or similar materials. Viscosity results by this test method are in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15452013STANDARDTESTMETHODFORVISCOSITYOFTRANSPARENTLIQUIDSBYBUBBLETIMEMETHOD 起泡 时间 测定 透明 液体 粘度 标准

链接地址:http://www.mydoc123.com/p-510002.html