1、Designation: D153 84 (Reapproved 2014)Standard Test Methods forSpecific Gravity of Pigments1This standard is issued under the fixed designation D153; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 These test methods cover three procedures for determi
3、n-ing the specific gravity of pigments, as follows:Test Method AFor Routine Testing of Several SamplesSimultaneously.Test Method BFor Tests Requiring Greater Accuracy thanTest Method A.Test Method CFor Rapid and Accurate Testing of SingleSamples.1.2 The specific gravity value obtained by these proce
4、duresmay be used with the weight of a dry pigment to determine thevolume occupied by the pigment in a coating formulation.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of
5、thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Sections 5, 11, and 15.2. Refere
6、nced Documents2.1 ASTM Standards:2D1193 Specification for Reagent Water3. Purity of Reagents3.1 Purity of WaterReference to water shall be understoodto mean reagent water as defined by Type II of SpecificationD1193.TEST METHOD AFOR ROUTINE TESTING OFSEVERAL SAMPLES SIMULTANEOUSLY4. Apparatus and Mat
7、erials4.1 PycnometerA pycnometer (Note 1) having a 50-mLcapacity.NOTE 1The Weld type with the cap seal on the outside of the neck ofthe bottle is preferred because there is less danger of trapping air justunder the capillary tube than with types having the ground glass seal onthe inside of the neck.
8、4.2 Water Bath, maintained at 25 6 0.5C and equippedwith a stirring device.4.3 Manometer, open- or closed-tube (see Part f of theapparatus for Test Method C), made of glass tubing 6 mm indiameter, fitted with rubber pressure tubing attached to aT-joint leading to the desiccator and the pump. For the
9、open-tube type 860 mm of mercury shall be used. Thedifference in levels of the mercury in the manometer when thesystem is in operation, subtracted from the barometer readingtaken at the same time, shall be considered the absolutepressure of the system in millimetres of mercury.4.4 Desiccator, glass,
10、 constructed with heavy walls to with-stand a vacuum of one atmosphere, and with an opening at theside.4.5 Vacuum PumpsA laboratory water vacuum-type pump(Note 2), to remove the greater portion of air in the desiccator,and an oil vacuum-type pump, motor-driven, and capable ofreducing the absolute pr
11、essure of the system to 3 mm.NOTE 2The water vacuum pump may be omitted if the rate ofevacuation with the oil pump can be controlled so as to avoid a rapidebullition of entrapped air and possible loss of specimen.4.6 Thermometer, having a range from 0 to 60C, andgraduated in 0.1C divisions.4.7 Weigh
12、ing Bottle, wide-mouth cylindrical glass (about 30mm in height and 70 mm in diameter), provided with aground-glass stopper.4.8 Immersion LiquidKerosine has been found to be agood wetting vehicle for most pigments, and shall be usedgenerally as the immersion liquid. Refined, white kerosine ofnarrow e
13、vaporation and boiling range shall be used. With some1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.31 on Pigment Specifications.Current edition approved Dec. 1, 2014.
14、 Published December 2014. Originallyapproved in 1923. Last previous edition approved in 2008 as D153 84 (2008).DOI: 10.1520/D0153-84R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in
15、formation, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1pigments that are not wetted well with kerosine, other immer-sion liquids such as glycerin, ethylene glycol,tet
16、rahydronaphthalene, etc., may be substituted. The liquidmust have a low evaporation rate and narrow boiling range,and the same procedure shall be followed as with kerosine.Water is not a preferred liquid because of the possibility offrothing.5. Hazards5.1 Before a desiccator is used for the first ti
17、me, wrap it ina towel and test under an absolute pressure of under 3 mm.Exercise care in handling the desiccator when under vacuum,since a sudden jar may cause it to collapse.6. Standardization of Pycnometer6.1 Fill the pycnometer with freshly boiled water at 23 to24C, gradually bring to 25 6 0.5C,
18、and then dry and weighas specified in 7.6. Empty the pycnometer, and clean, dry, andreweigh it. Next fill the pycnometer with kerosine at 23 to24C, bring to 25 6 0.5C, dry, and weigh as before. Calculatethe specific gravity, S, of the kerosine at 25/25C as follows:S 5 A/B (1)where:A = weight of kero
19、sine, g, andB = weight of water, g.7. Procedure7.1 DryingDry the pigment, preferably in an electricoven, at 105 6 2C for 2 h.7.2 WeighingTransfer to a clean, dry, weighedpycnometer, sufficient sample to form a layer approximately 20mm (34 in.) deep. For black, blue, and lake pigments of lowspecific
20、gravity, use about1gofsample; for inert crystallinepigments, about 4 g; for opaque white pigments, 7 to 10 g; andfor red lead, from 15 to 20 g. Weigh pigments of a hydroscopicnature from the weighing bottle.7.3 Number of SpecimensRun all samples at least induplicate.7.4 Addition of KerosineAdd enoug
21、h kerosine to thepycnometer to form a clear layer approximately14 in. (6 mm)above the pigment. When necessary, stir the specimen with apolished round-bottom glass rod until completely covered bykerosine, adding more kerosine if necessary. Wash the rod withkerosine, adding the washings to the pycnome
22、ter.7.5 Removal of Occluded AirPlace the pycnometer in thedesiccator. Close the desiccator and attach to the water pumpuntil the greater part of the air is removed from the system.Complete this procedure within a period of 5 to 10 min. Closethe system with a pinchcock and attach the desiccator to th
23、e oilpump for the removal of the small amounts of air given off atthe low pressures obtainable with the oil pump. Use themanometer to indicate whether the oil pump is giving theproper vacuum. When the manometer indicates that the abso-lute pressure is 3 mm and constant, cut off the oil pump forshort
24、 periods, taking care that the vacuum does not changematerially due to leakage. At first bubbles of air rise from thepigments very rapidly, then this action gradually decreases andfinally stops. The time required for complete removal of airmay vary from 30 min to 24 h, depending upon the nature ofth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15319842014STANDARDTESTMETHODSFORSPECIFICGRAVITYOFPIGMENTS 颜料 比重 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509982.html