ASTM D1492-2008e1 Standard Test Method for Bromine Index of Aromatic Hydrocarbons by Coulometric Titration《库仑计滴定法测定芳烃溴指数的标准试验方法》.pdf
《ASTM D1492-2008e1 Standard Test Method for Bromine Index of Aromatic Hydrocarbons by Coulometric Titration《库仑计滴定法测定芳烃溴指数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1492-2008e1 Standard Test Method for Bromine Index of Aromatic Hydrocarbons by Coulometric Titration《库仑计滴定法测定芳烃溴指数的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1492 081Standard Test Method forBromine Index of Aromatic Hydrocarbons by CoulometricTitration1This standard is issued under the fixed designation D1492; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEMercury warning was editorially added in March 2010.1. Scope*1.1 This test method covers the determination of the amountof bromi
3、ne-reactive material in aromatic hydrocarbons. It isusually applied to materials having bromine indexes below500.NOTE 1Other test methods for determining bromine-reactive materialare Test Methods D1159, D1491, D2710, and D5776.1.2 This test method has been found applicable to aromatichydrocarbons co
4、ntaining no more than trace amounts of olefinsand that are substantially free from material lighter thanisobutane and have a distillation end point under 288C.1.3 The following applies to all specified limits in this testmethod: For purposes of determining conformance with thistest method, an observ
5、ed value or a calculated value shall berounded off “to the nearest unit” in the last right-hand digitused in expressing the specification limit, in accordance withthe rounding-off method of Practice E29.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement ar
6、e included in thisstandard.1.5 WarningMercury has been designated by EPA andmany state agencies as a hazardous material that can causecentral nervous system, kidney, and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling me
7、rcury andmercury-containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website(http:/www.epa.gov/mercury/faq.htm) for additional informa-tion. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be pr
8、ohibited bystate law.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior t
9、o use. For a specifichazard statement see Section 8.2. Referenced Documents2.1 ASTM Standards:2D891 Test Methods for Specific Gravity, Apparent, ofLiquid Industrial ChemicalsD1159 Test Method for Bromine Numbers of PetroleumDistillates and Commercial Aliphatic Olefins by Electro-metric TitrationD119
10、3 Specification for Reagent WaterD1491 Test Method for Bromine Index of Aromatic Hydro-carbons by Potentiometric Titration3D2710 Test Method for Bromine Index of Petroleum Hy-drocarbons by Electrometric TitrationD3437 Practice for Sampling and Handling Liquid CyclicProductsD3505 Test Method for Dens
11、ity or Relative Density of PureLiquid ChemicalsD4052 Test Method for Density, Relative Density, and APIGravity of Liquids by Digital Density MeterD5776 Test Method for Bromine Index of Aromatic Hydro-carbons by Electrometric TitrationD6809 Guide for Quality Control and Quality AssuranceProcedures fo
12、r Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications2.2 Other Document:1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct respons
13、ibility ofSubcommittee D16.04 on Instrumental Analysis.Current edition approved July 1, 2008. Published August 2008. Originallyapproved in 1957. Last previous edition approved in 2007 as D1492 07. DOI:10.1520/D1492-08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS
14、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1*A Summary of Changes section appears at the en
15、d of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120043. Terminology3.1 Definition:3.1.1 bromine index (B), nthe number of milligrams (mg)of bromine consumed by 1
16、00 g of sample under givenconditions (mg-Br/100 g).4. Summary of Test Method4.1 The specimen is added to a solvent and titrated withelectrolytically generated bromine at room temperature. Theend point is determined by a dead-stop method. The time oftitration is proportional to the bromine added to t
17、he specimen.5. Significance and Use5.1 This test method is useful for setting specification, foruse as an internal quality control tool, and for use in develop-ment or research work on industrial aromatic hydrocarbons andrelated materials. This test method gives a broad indication ofolefinic content
18、. It will not differentiate between the types ofaliphatic unsaturation.6. Apparatus6.1 Amperometric-Coulometric Apparatus, automatic, suit-able for bromine index titrations with variable generatorcurrent and timer. A typical circuit diagram of suitable equip-ment is shown in Fig. 1.6.2 Syringe, 2 mL
19、 with needle and rubber cap seal.6.3 Stirrer, magnetic.7. Reagents7.1 Purity of ReagentReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical
20、Society,where such specifications are available.5Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be un
21、derstood to mean reagent water conformingto Type IV of Specification D1193.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.5Reagent Chemicals, American Chemical Society Specifications,
22、AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH, Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc.
23、 (USPC), Rockville,MD.FIG. 1 Automatic Amperometric-Coulometric Titrator CircuitD1492 08127.3 Electrolyte:7.3.1 With Mercury II AcetateTo make 1 L, mix 600 mLof glacial acetic acid, 260 mL of absolute methanol, and 140mL of KBr solution (119 g/L). Dissolve2gofMercury IIacetate in this mixture.7.3.2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD14922008E1STANDARDTESTMETHODFORBROMINEINDEXOFAROMATICHYDROCARBONSBYCOULOMETRICTITRATION 库仑计 滴定法

链接地址:http://www.mydoc123.com/p-509895.html