ASTM D1481-2002(2007) Standard Test Method for Density and Relative Density (Specific Gravity) of Viscous Materials by Lipkin Bicapillary Pycnometer《用利普金双毛细管比重计测定粘性材料密度和相对密度(比重)的标准.pdf
《ASTM D1481-2002(2007) Standard Test Method for Density and Relative Density (Specific Gravity) of Viscous Materials by Lipkin Bicapillary Pycnometer《用利普金双毛细管比重计测定粘性材料密度和相对密度(比重)的标准.pdf》由会员分享,可在线阅读,更多相关《ASTM D1481-2002(2007) Standard Test Method for Density and Relative Density (Specific Gravity) of Viscous Materials by Lipkin Bicapillary Pycnometer《用利普金双毛细管比重计测定粘性材料密度和相对密度(比重)的标准.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1481 02 (Reapproved 2007)An American National StandardStandard Test Method forDensity and Relative Density (Specific Gravity) of ViscousMaterials by Lipkin Bicapillary Pycnometer1This standard is issued under the fixed designation D 1481; the number immediately following the designati
2、on indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determ
3、ination of the densityof oils more viscous than 15 cSt at 20C (mm2/s), and ofviscous oils and melted waxes at elevated temperatures, but notat temperatures at which the sample would have a vaporpressure of 100 mm Hg (13 kPa) or above.NOTE 1To determine the densities of less viscous liquids at 20 or2
4、5C use Test Method D 1217.1.2 This test method provides a calculation procedure forconverting density to relative density (specific gravity).1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport
5、 to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1217
6、 Test Method for Density and Relative Density(Specific Gravity) of Liquids by Bingham PycnometerD 1250 Guide for Use of the Petroleum MeasurementTables3. Terminology3.1 Definitions:3.1.1 densitythe weight in a vacuum (that is, the mass) ofa unit volume of the material at any given temperature.3.1.2
7、relative density (specific gravity)the ratio of themass (weight in a vacuum) of a given volume of material at atemperature, t1, to the mass of an equal volume of water at areference temperature, t2; or the ratio of the density of thematerial at t1to the density of water at t2.4. Summary of Test Meth
8、od34.1 The liquid is drawn into the bicapillary pycnometerthrough the removable siphon arm and adjusted to volume atthe temperature of test, in such a manner that there ispractically no drainage in the unfilled tubing. After equilibra-tion at the test temperature, liquid levels are read, and thepycn
9、ometer is removed from the thermostated bath, cooled toroom temperature, and weighed.4.2 Density or relative density (specific gravity), as desired,is then calculated from the volume at the test temperature andthe weight of the sample. The effect of air buoyancy is includedin the calculations.5. Sig
10、nificance and Use5.1 Density is a fundamental physical property that can beused in conjunction with other properties to characterize boththe light and heavy fractions of petroleum and to access thequality of crude oils.5.2 Determination of the density or relative density ofpetroleum and its products
11、 is necessary for the conversion ofmeasured volumes to volumes at the standard temperatures of15C.5.3 The determination of densities at the elevated tempera-tures of 40 and 100C is particularly useful in providing thedata needed for the conversion of kinematic viscosities incentistokes (mm2/s) to th
12、e corresponding dynamic viscositiesin centipoises (mPas).6. Apparatus6.1 Pycnometer4Aside-arm type of pycnometer conform-ing to the dimensions given in Fig. 1 and made of borosilicateglass. The weight shall not exceed 35 g without the side arm.1This test method is under the jurisdiction of ASTM Comm
13、ittee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0D on Physical and Chemical Methods.Current edition approved Nov. 1, 2007. Published January 2008. Originallyapproved in 1957. Last previous edition approved in 2002 as D 148102.2For referenced ASTM
14、standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3For a more complete discussion of this procedure, see Lipkin, M. R., Mills, I.W.,
15、 Martin, C. C., and Harvey, W. T., Analytical Chemistry, ANCHA, Vol 21, 1949,p. 504.4The sole source of supply of the pycnometers known to the committee at thistime is Reliance Glass Co., 220 Gateway Rd., Bensenville, IL 60106-0825 havebeen found satisfactory. If you are aware of alternative supplie
16、rs, please provide thisinformation to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee,1whichyou may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
17、States.6.2 RackA rack to use in filling the pycnometer (see Fig.2).6.3 Constant-Temperature OvenAn oven for use in fillingthe pycnometer. Any oven capable of holding the filling rack,and of maintaining a temperature of approximately 100C, canbe used.6.4 Constant-Temperature BathA mixture of water an
18、dglycerin, or oil bath having a depth of at least 305 mm (12 in.)and provided with heating, stirring, and thermostating devicesadequate to maintain desired temperatures in the range from 20to 100C with an accuracy of 60.01C.6.5 Bath ThermometersThermometers graduated in 0.1Csubdivisions and standard
19、ized for the range of use to thenearest 0.01C (ASTM Saybolt Viscosity Thermometers 17Cto 22C are recommended). For most hydrocarbons, the densitycoefficient is about 0.0008 units/C, and therefore a tempera-ture error of 60.013C would cause an error of 60.000 01 indensity.6.6 Pycnometer HolderA holde
20、r, as shown in Fig. 3,isrecommended for supporting the pycnometer in the bath. Asingle clamp device may be used.6.7 BalanceAbalance able to reproduce weighings within0.1 mg when carrying a load of 35 g or less on each pan. Thebalance shall be located in a room shielded from drafts andfumes and in wh
21、ich the temperature changes between relatedweighings (empty and filled pycnometer) do not cause asignificant change in the ratio of the balance arms. Otherwise,weighings shall be made by the substitution method in whichthe calibrated weights and pycnometer are alternativelyweighed on the same balanc
22、e pan. The same balance shall beused for all related weighings.6.8 WeightsWeights shall be used whose relative valuesare known to the nearest 0.05 mg or better. The same set ofweights shall be used for the calibration of the pycnometer andthe determination of the densities, or the sets of weights sh
23、allbe calibrated relative to each other.7. Reagents and Materials7.1 Acetone(WarningExtremely flammable. Use ad-equate ventilation.)7.2 Isopentane(WarningExtremely flammable. Avoidbuildup of vapors and remove all sources of ignition, especiallynonexplosion-proof electrical apparatus.)7.3 Chromic Aci
24、d (Potassium Dichromate/Conc. SulfuricAcid)(WarningCauses severe burns. A recognized car-cinogen. Do not get in eyes, on skin or clothing.)7.4 Xylenes(WarningFlammable liquid. Aspirationhazard. May irritate skin, eyes, respiratory tract or digestivetract, or both. May cause central nervous system de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD148120022007STANDARDTESTMETHODFORDENSITYANDRELATIVEDENSITYSPECIFICGRAVITYOFVISCOUSMATERIALSBYLIPKINBICAPILLARYPYCNOMETER

链接地址:http://www.mydoc123.com/p-509872.html