ASTM D1465-2004 Standard Test Method for Blocking and Picking Points of Petroleum Wax《石油蜡的熔点和粘着点的标准试验方法》.pdf
《ASTM D1465-2004 Standard Test Method for Blocking and Picking Points of Petroleum Wax《石油蜡的熔点和粘着点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1465-2004 Standard Test Method for Blocking and Picking Points of Petroleum Wax《石油蜡的熔点和粘着点的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1465 04An American National StandardTechnical Association of Pulp and Paper IndustrySuggested Method T 652Standard Test Method forBlocking and Picking Points of Petroleum Wax1This standard is issued under the fixed designation D 1465; the number immediately following the designation i
2、ndicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determina
3、tion of the block-ing point and picking point of petroleum wax.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applic
4、a-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 87 Test Method for Melting Point of Petroleum Wax(Cooling Curve)D 938 Test Method for Congealing Point of PetroleumWaxes, Including PetrolatumD 2423 Test Method for Surface Wax on Waxed Paper orPaperboardE 1
5、 Specification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions:3.1.1 wax blocking pointthe lowest temperature at whichfilm disruption occurs across 50 % of the waxed paper surfacewhen the test strips are separated.3.1.2 wax picking pointthe temperature at which the firstfilm disru
6、ption occurs on the waxed paper when test strips areseparated.4. Summary of Test Method4.1 Paper test specimens are coated with the wax sample,folded with the waxed surfaces together, and placed on ablocking plate. The plate is heated at one end and cooled at theother end to impose a measured temper
7、ature gradient along itslength. After a conditioning period on the plate, the specimensare removed, unfolded, and examined. The points of initial filmdisruption (picking point) and where 50 % of the specimenwidth is disrupted (50 % blocking point) are noted. Thetemperatures of corresponding points o
8、n the blocking plate arereported as the picking point and blocking point or blockingrange.5. Significance and Use5.1 Blocking of waxed paper, because of the relatively lowtemperatures at which it may occur, can be a major problem tothe paper-coating industry. For example, when the waxedsurfaces in a
9、 roll of waxed paper stick together, upon separa-tion the surface films are marred and the glossy finish isdestroyed. The wax picking point and the wax blocking pointindicate an approximate temperature range at or above whichwaxed surfaces in contact with each other are likely to causesurface film i
10、njury.6. Apparatus6.1 Wax Coating DeviceAny manual- or machine-drivenwaxer that gives uniform coatings of the desired weights to astrip of paper not less than 51 mm (2 in.) wide.6.2 Trimming Board, or other device for cutting paper strips.6.3 Paper Scales, sensitive to 0.002 g, or suitable balancefo
11、r measuring basis weights of unwaxed and waxed paper.6.4 Blocking Plate Assembly, consisting of a metal plate 305mm (12 in.) wide, 13 to 51 mm (12 to 2 in.) thick, and 559 to914 mm (22 to 36 in.) long. It is heated at one end and cooledat the other end to provide a 457 to 762-mm (18 to 30-in.) tests
12、ection having an average temperature gradient of 0.8 to 2.2C(1.5 to 4.0F)/in. The temperature gradient across the width ofthe plate from the longitudinal axis to 25 mm (1 in.) from theedge must not exceed 0.3C (0.5F). The temperature at anypoint should not vary more than 0.3C (0.5F). Details of twoa
13、cceptable blocking plates are given in Fig. 1 and Fig. 2.6.4.1 Eight Foam Rubber Strips,25to38mm(1to112 in.)wide by 6 to 13 mm (14 to12 in.) thick, extending the lengthof the test section on the blocking plate.6.4.2 Eight Sets of Steel Weights, 25 by 25 mm (1 by 1 in.)in cross section made from stoc
14、k having a density range from7800 to 8000 kg/m3(0.28 to 0.29 lb/in3). The weights may be1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.10 on Properties of Petroleum Wax. This test method was pr
15、epared jointly bythe Technical Association of the Pulp and Paper Industry and the American Societyfor Testing and Materials.Current edition approved Nov. 1, 2004. Published November 2004. Originallyapproved in 1957. Last previous edition approved in 2000 as D 146590(2000).2For referenced ASTM standa
16、rds, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM Intern
17、ational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.in single lengths or in sections to give sets equaling the lengthof the test section of the blocking plate.6.5 Temperature Recorder, or indicator for measuring thetemperature gradient of the blocking plate.
18、The instrument andthermocouples when calibrated shall consistently be accurateto 6 0.3C (0.5F).6.6 ThermometersFor water bath and wax bath on thewaxing device, use two ASTM Tag Closed Tester Thermom-eters having a range from 5 to 110C (20 to 230F), graduatedin 0.5C (1F) subdivisions, and conforming
19、to Thermometer9C or 9F as prescribed in Specification E1.7. Test Paper7.1 PaperCereal glassine of basis weight 46 to 51 g/m2(28.5 to 31.5 lb/3000 ft2).FIG. 1 Type A Blocking PlateFIG. 2 Type B Blocking PlateD14650428. Sampling8.1 Select a portion of the wax that is representative of thewhole sample.
20、 The amount required will depend on the size ofthe waxing device used.9. Standardization of Apparatus9.1 Turn the blocking plate on with all sponge rubber stripsand metal blocks in position. Allow sufficient time (3 hminimum) for the plate to reach an equilibrium temperaturecondition.9.2 Calibrate a
21、 30-gage “test” thermocouple as follows:Heat a beaker of water to about 43.3C (110F) and measure itstemperature with a standardized thermometer which is accurateto 0.3C (0.5F). Insert the “test” thermocouple in the waterand measure the temperature with a manual potentiometerwhich is accurate to at l
22、east 60.5C (61F). A portableprecision type potentiometer or a type K potentiometer, both ofwhich are accurate to at least 0.5F (0.3C) in this temperaturerange, is preferred.9.3 Lay the calibrated “test” thermocouple across the widthof the plate with its junction directly over one of the imbeddedther
23、mocouples. Be sure that one of the sponge rubber stripscovers the junction completely. Replace the weights on therubber strips.After 3 to 4 min, note the temperature readings onthe hand potentiometer and the corresponding point on therecorder. If the reading of the test thermocouple plus itscalibrat
24、ion factor is more than 0.5C (1F) from that of therecorder reading, check the accuracy of the recorder separately.If the recorder is satisfactory, the trouble may result from thethermocouple being damaged or not in solid contact with theplate. Replace this thermocouple, taking care to tamp it intopl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD14652004STANDARDTESTMETHODFORBLOCKINGANDPICKINGPOINTSOFPETROLEUMWAX 石油 熔点 粘着 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509851.html