ASTM D1388-2007 Standard Test Method for Stiffness of Fabrics《织物硬挺性标准试验方法》.pdf
《ASTM D1388-2007 Standard Test Method for Stiffness of Fabrics《织物硬挺性标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1388-2007 Standard Test Method for Stiffness of Fabrics《织物硬挺性标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1388 07Standard Test Method forStiffness of Fabrics1This standard is issued under the fixed designation D 1388; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indic
2、ates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of stiffnessproperties of fabrics. Bending length is measured and flexuralrigidity is calculated. Two procedures are prov
3、ided.1.1.1 Option ACantilever Test, employing the principle ofcantilever bending of the fabric under its own mass.1.1.2 Option BHeart Loop Test, employing the principleof a loop formed in a fabric strip and hung vertically.1.2 This test method applies to most fabrics includingwoven fabrics, air bag
4、fabrics, blankets, napped fabrics, knittedfabrics, layered fabrics, pile fabrics. The fabrics may beuntreated, heavily sized, coated, resin-treated, or otherwisetreated.1.3 The values stated in SI units are to be regarded as thestandard. The U.S. customary units may be approximate.1.4 This standard
5、does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM S
6、tandards:2D 123 Terminology Relating to TextilesD 1776 Practice for Conditioning and Testing TextilesD 2904 Practice for Interlaboratory Testing of a Textile TestMethod that Produces Normally Distributed DataD 2906 Practice for Statements on Precision and Bias forTextilesD 3776 Test Methods for Mass
7、 Per Unit Area (Weight) ofFabricD 4850 Terminology Relating to Fabric3. Terminology3.1 For all terminology relating to D13.59, Fabric TestMethods, General, refer to Terminology D 4850.3.1.1 The following terms are relevant to this standard:bending length, cross-machine direction, CD, fabric, flexura
8、lrigidity, machine direction, MD, stiffness.3.2 For all other terminology related to textiles, refer toTerminology D 123.4. Summary of Test Method Options4.1 Option A, Cantilever TestA specimen is slid at aspecified rate in a direction parallel to its long dimension, untilits leading edge projects f
9、rom the edge of a horizontal surface.The length of the overhang is measured when the tip of thespecimen is depressed under its own mass to the point wherethe line joining the top to the edge of the platform makes a0.724 rad (41.5) angle with the horizontal. From this mea-sured length, the bending le
10、ngth and flexural rigidity arecalculated.4.2 Option B, Heart Loop TestA strip of fabric is formedinto a heart-shaped loop. The length of the loop is measuredwhen it is hanging vertically under its own mass. From thismeasured length, the bending length and flexural rigidity arecalculated.5. Significa
11、nce and Use5.1 Both test options in this test method are consideredsatisfactory for acceptance testing of commercial shipmentssince current estimates of between-laboratory precision areacceptable and the method is used extensively in the trade foracceptance testing.5.1.1 In case of a dispute arising
12、 from differences inreported test results when using this test method for acceptancetesting of commercial shipments, the purchaser and the sup-plier should conduct comparative tests to determine if there isa statistical bias between their laboratories. Competent statis-tical assistance is recommende
13、d for the investigation of bias.As a minimum, the two parties should take a group of testspecimens that are as homogeneous as possible and that arefrom a lot of material of the type in question. Test specimensshould then be randomly assigned in equal numbers to eachlaboratory for testing. The averag
14、e results from the two1This test method is under the jurisdiction ofASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.60 on Fabric Test Methods,Specific.Current edition approved July 1, 2007. Published August 2007. Originallyapproved in 1956. Discontinued 1995 and re
15、instated as D 1388 96. Last previousedition approved in 2002 as D 138896(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page o
16、nthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.laboratories should be compared using the appropriate statis-tical analysis and an acceptable probability level chosen by thetwo parties before testing is begun. If a
17、bias is found, either itscause must be found and corrected or the purchaser and thesupplier must agree to interpret future test results with consid-eration to the known bias.5.2 In general, these procedures are more suitable for testingwoven fabrics than knit fabrics.5.3 The Cantilever Test Option i
18、s the preferred procedurebecause it is simpler to perform. It is, however, not suitable forvery limp fabrics or those that show a marked tendency to curlor twist at a cut edge.5.4 The Heart Loop Test Option is suitable for fabrics thatshow a tendency to curl or twist.5.5 Both options can provide a c
19、orrelation with a subjectiveevaluation of a given fabric type. That is, a higher numberrepresents a stiffer fabric.5.6 The stiffness of a fabric may change with storage.5.7 No evidence has been found showing that bendinglength is dependent on the width. The tendency for specimensto curl or twist wil
20、l affect the result, because of the rigidityprovided at the edge. Consequently, the wider the strip, the lessimportant is the edge effect.6. Apparatus6.1 Option ACantilever Bending Tester3(Fig. 1).6.1.1 Horizontal Platform, with a minimum area of 38 by200 mm (1.5 by 8 in.) and having a smooth low-fr
21、iction, flatsurface such as polished metal or plastic. A leveling bubbleshall be incorporated in the platform.6.1.1.1 Indicator, inclined at an angle of 0.724 6 0.01 rad(41.5 6 0.5) below the plane of the platform surface.6.1.1.2 Movable Slide, consisting of a metal bar not lessthan 25 by 200 mm (1
22、by 8 in.) by approximately 3 mm (18 in.)thick and having a mass of 270 6 5 g (0.6 6 0.01 lb).6.1.1.3 Scale and Reference Point, to measure the length ofthe overhang.6.1.1.4 Specimen Feed Unit, motorized3(see Fig. 1) set to120 mm/min (4.75 in./min) 65 %, or manual equivalent.6.1.2 Cutting Die25 6 1mm
23、by2006 1mm(16 0.04in. by 8 6 0.04 in.).6.2 Option BHeart Loop Tester.6.2.1 Clamp and Stand, for hanging the specimen.6.2.2 Scale, suitably mounted on the stand for measuring thelength of the specimen loop and calibrated either in cm (in.) ordirectly in bending length.NOTE 1If a constant strip length
24、 is adopted, the scale may becalibrated to read directly in units of bending length.6.2.3 Brass Bars, two, 25 3 75 3 3 6 0.1 mm(1 3 3 3 0.1256 0.005 in.).6.2.4 Pressure Sensitive Tape.6.2.5 Jig, constructed to allow positioning of the two barswith their inner edges parallel and at a distance from ea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD13882007STANDARDTESTMETHODFORSTIFFNESSOFFABRICS 织物 硬挺 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509717.html