1、Designation: D 1293 99 (Reapproved 2005)Standard Test Methods forpH of Water1This standard is issued under the fixed designation D 1293; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover the determination of pH byelectrometric measu
3、rement using the glass electrode as thesensor. Two test methods are given as follows:SectionsTest Method APrecise Laboratory Measurement 8 to 15Test Method BRoutine or Continuous Measurement 16 to 241.2 Test Method A covers the precise measurement of pH inwater utilizing at least two of seven standa
4、rd reference buffersolutions for instrument standardization.1.3 Test Method B covers the routine measurement of pH inwater and is especially useful for continuous monitoring. Twobuffers are used to standardize the instrument under controlledparameters, but the conditions are somewhat less restrictiv
5、ethan those in Test Method A.1.4 Both test methods are based on the pH scale establishedby NIST (formerly NBS) Standard Reference Materials.21.5 Neither test method is considered to be adequate formeasurement of pH in water whose conductivity is less thanabout 5 S/cm. Refer to Test Methods D 5128 an
6、d D 5464.1.6 Precision and bias data were obtained using buffersolutions only. It is the users responsibility to assure thevalidity of these test methods for untested types of water.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theres
7、ponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 1066 Practice for Sampling SteamD 1067 Test Methods for Acidity or Alkalinity of WaterD
8、1129 Terminology Relating to WaterD 1192 Specification for Equipment for Sampling Waterand Steam in Closed Conduits4D 1193 Specification for Reagent WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on WaterD 3370 Practices for Sampling Water from Clo
9、sed ConduitsD 5128 Test Method for On-Line pH Measurement of Waterof Low ConductivityD 5464 Test Methods for pH Measurement of Water of LowConductivityE70Test Method for pH of Aqueous Solutions with theGlass Electrode3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, re
10、fer to Terminology D 1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 pH, nthe pH of an aqueous solution is derived fromE, the electromotive force (emf) of the cellglass electrode | solution | reference electrode(where the double vertical line represents a liquid junction)when the elect
11、rodes are immersed in the solution in thediagrammed position, and Esis the electromotive force ob-tained when the electrodes are immersed in a reference buffersolution.With the assigned pH of the reference buffer designated aspHs, and E and Esexpressed in volts is the following:5pH 5 pHs1E 2 Es!F2.3
12、026 RTwhere:F = Faraday,R = gas constant, andT = absolute temperature, t (C) + 273.15.The reciprocal of F/2.3026 RT is known as the slope of theelectrode, and is the expected difference in observed voltage1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct
13、 responsibility of Subcommittee D19.03 on Sampling ofWater and Water-Formed Deposits, Analysis of Water for Power Generation andProcess Use, On-Line Water Analysis, and Surveillance of Water.Current edition approved Jan. 1, 2005. Published January 2005. Originallyapproved in 1953. Last previous edit
14、ion approved in 1999 as D 1293 99.2“Standard Reference Materials: Standardization of pH Measurements” Wu andKoch, NBS Special Publications No. 260-53, 1988.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AST
15、MStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.5Bates, R. G., Determination of pH: Theory and Practice, 2nd Ed., J. Wiley andSons, New York, 1973, p. 29.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
16、 19428-2959, United States.for two measurements one pH unit apart. Values of the slope atvarious temperatures are given in Table 1.4. Summary of Test Method4.1 The pH meter and associated electrodes are standardizedagainst two reference buffer solutions that closely bracket theanticipated sample pH.
17、 The sample measurement is madeunder strictly controlled conditions and prescribed techniques.5. Significance and Use5.1 The pH of water is a critical parameter affecting thesolubility of trace minerals, the ability of the water to formscale or to cause metallic corrosion, and the suitability of the
18、water to sustain living organisms. It is a defined scale, based ona system of buffer solutions2with assigned values. In purewater at 25C, pH 7.0 is the neutral point, but this varies withtemperature and the ionic strength of the sample.6Pure waterin equilibrium with air has a pH of about 5.5, and mo
19、st naturaluncontaminated waters range between pH 6 and pH 9.6. Purity of Reagents6.1 Reagent grade chemicals shall be used in all tests,except as specifically noted for preparation of reference buffersolutions. Unless otherwise indicated, it is intended that allreagents shall conform to the specific
20、ations of the Committeeon Analytical Reagents of the American Chemical Society,where such specifications are available.7Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Pu
21、rity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D 1193, Type I.7. Sampling7.1 Collect samples in accordance with Practice D 1066,Specification D 1192, or Practices D 3370, whichever is appli-cable.TEST METHOD APRECISE L
22、ABORATORYMEASUREMENT OF pH8. Scope8.1 This test method covers the precise measurement of pHin water under strictly controlled laboratory conditions.9. Interferences9.1 The glass electrode reliably measures pH in nearly allaqueous solutions and in general is not subject to solutioninterference from c
23、olor, turbidity, colloidal matter, oxidants, orreductants.9.2 The reference electrode may be subject to interferencesand should be chosen to conform to all requirements ofSections 10 and 12. Refer also to Appendix X1.3.9.3 The true pH of an aqueous solution or extract is affectedby the temperature.
24、The electromotive force between the glassand the reference electrode is a function of temperature as wellas pH. The temperature effect can be compensated automati-cally in many instruments or can be manually compensated inmost other instruments. The temperature compensation cor-rects for the effect
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD129319992005STANDARDTESTMETHODSFORPHOFWATER PH 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-509589.html