ASTM D1243-2015 Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers《氯乙烯聚合物的稀释溶液粘度的标准试验方法》.pdf
《ASTM D1243-2015 Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers《氯乙烯聚合物的稀释溶液粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1243-2015 Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers《氯乙烯聚合物的稀释溶液粘度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1243 14D1243 15Standard Test Method forDilute Solution Viscosity of Vinyl Chloride Polymers1This standard is issued under the fixed designation D1243; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the dilute solution viscosity of vinyl chloride polymers in cyclohexanone. The
3、viscosity is expressed in terms of inherent viscosity (logarithmic viscosity number). The test method is limited to those materialsthat give clear, uniform solutions at the test dilution.NOTE 1Other expressions for viscosity may be used as described in the Appendix, but any change from the test meth
4、od as specified shall be statedin the report.1.2 The values stated in SI units are to be regarded as the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate s
5、afety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 2This standard and ISO 1628-2 address the same subject matter, but differ in technical content.2. Referenced Documents2.1 ASTM Standards:2D445 Test Method for Kinematic Viscosity of Transparent and
6、Opaque Liquids (and Calculation of Dynamic Viscosity)D446 Specifications and Operating Instructions for Glass Capillary Kinematic ViscometersD883 Terminology Relating to PlasticsD1600 Terminology for Abbreviated Terms Relating to PlasticsD1755 Specification for Poly(Vinyl Chloride) ResinsD2857 Pract
7、ice for Dilute Solution Viscosity of PolymersE2251 Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids2.2 ISO Standard:ISO 1628-2 Determination of Viscosity Number and Limiting Viscosity NumberPart 2: Poly(Vinyl Chloride) Resins32.3 National Institute of Standards a
8、nd Technology Circular:4C-434 Testing of Glass Volumetric Apparatus3. Terminology3.1 DefinitionsDefinitions are in accordance with Terminology D883 and Terminology D1600, unless otherwise indicated.4. Summary of Test Method4.1 A sample of resin is dissolved in cyclohexanone to make a solution of spe
9、cified concentration. Inherent viscosity(logarithmic viscosity number) is calculated from the measured flow times of the solvent and of the polymer solution.NOTE 3For additional information, refer to Test Method D445 and Test Method D2857 for Dilute Solution Viscosity of Polymers.1 This test method
10、is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.15 on ThermoplasticMaterials.15.07).Current edition approved Oct. 1, 2014Oct. 1, 2015. Published October 2014October 2015. Originally approved in 1952. Last previous edition approved in 2
11、0082014 asD1243 - 95 (2008).D1243 - 14. DOI: 10.1520/D1243-14.10.1520/D1243-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on
12、 the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.4 Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.This d
13、ocument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions
14、as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Uni
15、ted States15. Significance and Use5.1 Dilute solution viscosity values for vinyl chloride polymers are related to the average molecular size of that portion of thepolymer that dissolves in the solvent.6. Apparatus6.1 Transfer Pipets.6.2 Volumetric Flasks, 100-mL, glass-stoppered, in accordance with
16、National Institute of Standards and Technology CircularC-434.6.3 Viscometer, ASTM Ubbelohde Size 1 or Cannon-Ubbelohde No. 75.NOTE 4ASTM Ubbelohde Size 1 is a commonly used name for a specific viscometer type, which is neither supplied nor endorsed by ASTMInternational.NOTE 4Operating instructions c
17、an be found in Specification D446.6.4 Water Bath, set at 30.0 6 0.5C, controlled to within 6 0.01C.6.4.1 The temperature of the bath medium shall not vary by more than 60.02C of the selected temperature in accordance withTest Method D445.6.5 Timer, as specified in Test Method D445, graduated in divi
18、sions of 0.1 s or less.6.6 Filter Funnel, fritted-glass.funnel, Hirsh-Type; borosilicate glass; w/coarse fritted disc, pore size: 4060 m.6.7 Thermometer, standard, in accordance with Method E2251.7. Materials7.1 SolventCyclohexanone, analytical reagent grade or laboratory-distilled technical grade,
19、boiling between 155 and 156Cat 760 mm Hg has been found acceptable if stored in a closed container.8. Procedure8.1 Dissolve duplicates of resin as follows: Weigh 0.2 6 0.002 g of the sample (moisture content below 0.1 %) and transfer itto a 100-mLglass-stoppered volumetric flask. Take care to transf
20、er all of the weighed resin into the flask.As an alternative method,weigh the resin (0.2 6 0.002 g) directly into a tared, 100-mL glass-stoppered volumetric flask.8.2 Add 50 to 70 mL of cyclohexanone to the flask, taking care to wet the resin so that lumps do not form.8.3 Heat the flask at 85 6 10C
21、until the resin is dissolved. Occasional shaking will reduce the time required for solution. Takecare that heating time does not exceed 12 h, preferably less, to minimize degradation. If any gel-like particles can be seen, preparea new solution.8.4 Cool the solution to the test temperature by immers
22、ing flask in the 30C bath for a minimum time of 30 min and adjust toa solution volume of 100 mL. Filter through a fritted-glass filter filter, as described in 6.6, directly into the viscometer.8.5 Measure at 30.0 6 0.5C the flow time of the prepared solution (8.4) and of the pure solvent (aged at 85
23、 6 10C) in theviscometer.Allow 10 min for the viscometer to come to temperature equilibrium after placing it in the water bath. If the flow timeof the solution or the solvent differs by more than 0.1 % on repeat runs on the same filling, the result is suspect.NOTE 5Keep the Ubbelohde viscometer clea
24、n when not in use.Acetone may be used to flush the pure solvent (Cyclohexanone) and enable subsequentdrying. The viscometer may be stored filled with pure solvent or it may be stored dry.9. Calculation9.1 Calculate the relative and inherent viscosity (viscosity ratio and logarithmic viscosity number
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD12432015STANDARDTESTMETHODFORDILUTESOLUTIONVISCOSITYOFVINYLCHLORIDEPOLYMERS 氯乙烯 聚合物 稀释 溶液 粘度 标准

链接地址:http://www.mydoc123.com/p-509509.html