ASTM D1217-1993(2003)e1 Standard Test Method for Density and Relative Density (Specific Gravity) of Liquids by Bingham Pycnometer《用宾汉比重法测定液体密度和相对密度(比重)的试验方法》.pdf
《ASTM D1217-1993(2003)e1 Standard Test Method for Density and Relative Density (Specific Gravity) of Liquids by Bingham Pycnometer《用宾汉比重法测定液体密度和相对密度(比重)的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1217-1993(2003)e1 Standard Test Method for Density and Relative Density (Specific Gravity) of Liquids by Bingham Pycnometer《用宾汉比重法测定液体密度和相对密度(比重)的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1217 93 (Reapproved 2003)e1An American National StandardStandard Test Method forDensity and Relative Density (Specific Gravity) of Liquids byBingham Pycnometer1This standard is issued under the fixed designation D 1217; the number immediately following the designation indicates the ye
2、ar oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Depart
3、ment of Defense.e1NOTEWarning notes were editorially moved into the standard text in November 2003.1. Scope1.1 This test method covers the measurement of the densityof pure hydrocarbons or petroleum distillates boiling between90 and 110C that can be handled in a normal fashion as aliquid at the spec
4、ified test temperatures of 20 and 25C.1.2 This test method provides a calculation procedure forthe conversion of density to relative density (specific gravity).1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns,
5、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific warningstatements are given in Section 7.2. Referenced Documents2.1 ASTM Stan
6、dards:2E 1 Specification for ASTM Thermometers3. Terminology3.1 Definitions:3.1.1 densitythe weight in vacuo, (that is, the mass) of aunit volume of the material at any given temperature.3.1.2 relative density (specific gravity)the ratio of themass (weight in vacuo) of a given volume of material at
7、atemperature, t1, to the mass of an equal volume of water at areference temperature, t2; or it is the ratio of the density of thematerial at t1to the density of water at t2. When the referencetemperature is 4.00C, the temperature at which the relativedensity of water is unity, relative density (spec
8、ific gravity) anddensity are numerically equal.4. Summary of Test Method4.1 The liquid sample is introduced into a pycnometer,equilibrated to the desired temperature, and weighed. Therelative density (specific gravity) or density is then calculatedfrom this weight and the previously determined weigh
9、t ofwater that is required to fill the pycnometer at the sametemperature, both weights being corrected for the buoyancy ofair.5. Significance and Use5.1 Density is a fundamental physical property which can beused in conjunction with other properties to characterize purehydrocarbons and their mixture
10、s.5.2 This test method was originally developed for thedetermination of the density of the ASTM Knock Test Refer-ence Fuels n-heptane and isooctane, with an accuracy of0.00003 g/mL. Although it is no longer employed extensivelyfor this purpose, this test method is useful whenever accuratedensities o
11、f pure hydrocarbons or petroleum fractions withboiling points between 90 and 110C are required.6. Apparatus6.1 Pycnometer, Bingham-type,3conforming to the dimen-sions given in Fig. 1, constructed of borosilicate glass, andhaving a total weight not exceeding 30 g.6.2 Constant-Temperature Bath, provid
12、ed with suitable py-cnometer holders or clips and means for maintaining tempera-tures constant to 60.01C in the desired range.6.3 Bath Thermometer, graduated in 0.1C subdivisions andstandardized for the ice point and the range of use to the nearest1This test method is under the jurisdiction of ASTM
13、Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04 on Hydrocarbon Analysis.Current edition approved Nov. 1, 2003. Published November 2003. Originallyapproved in 1952. Last previous edition approved in 1998 as D 121793 (1998).2For referenced ASTM
14、standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of the pycnometer known to the committee at thistime is
15、 Reliance Glass Co., 220 Gateway Rd., Bensenville, IL 60106-0825. If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,2which you may attend.1Co
16、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.0.01C. ASTM Saybolt Viscosity Thermometer 17C as pre-scribed in Specification E 1, designed for tests at 21.1C and25C, is recommended. A standardized platinum resistancethermometer may als
17、o be used, and offers the best means forobserving minute temperature changes in the bath. Whichevermeans are available, it must be realized that for most hydro-carbons the density coefficient is about 0.0008 units/C, andtherefore an error of 60.013C would cause an error of60.00001 in density.6.4 Hyp
18、odermic Syringe, 30-mL capacity, of chemicallyresistant glass, equipped with a 152-mm (6-in.) needle made ofstainless steel tubing as shown in Fig. 2.6.5 Draw-Off Needle, made of stainless steel tubing asshown in Fig. 2.6.6 Solvent-Cleaning Assembly, as shown in Fig. 3.6.7 Chromic Acid Cleaning Appa
19、ratus, similar to thatshown in Fig. 4.6.8 Balance, capable of reproducing weighings within 0.1mg. Mechanical balances should have sensitivity which causesthe pointer to be deflected 2 or 3 scale divisions per 1 mg whencarrying a load of 30 g or less on each pan. The balance shouldbe located in a roo
20、m shielded from drafts and fumes and inwhich the temperature changes between related weighings(empty and filled pycnometer) do not cause a significantchange in the ratio of the balance arms. Otherwise weighingsshall be made by the method of substitution, in which thecalibrated weights and pycnometer
21、 are alternately weighed onthe same balance pan. The same balance shall be used for allrelated weighings.6.9 Weights, whose relative values are known to the nearest0.05 mg or better. The same set of weights shall be used for thecalibration of the pycnometer and the determination of densi-ties.7. Rea
22、gents and Materials7.1 Acetone(WarningExtremely flammable. Use ad-equate ventilation.)7.2 Isopentane(WarningExtremely flammable. Avoidbuildup of vapors and remove all sources of ignition, especiallynon-explosion proof electrical apparatus.)7.3 Chromic Acid (Potassium Dichromate/Conc. SulfuricAcid)(W
23、arningCauses severe burns. A recognized car-cinogen. Do not get in eyes, or on skin or clothing.)8. Preparation of Apparatus8.1 Thoroughly clean the pycnometer with hot chromic acidcleaning solution by means of the assembly shown in Fig. 4.Chromic acid solution (WarningSee 7.3) is the most effec-tiv
24、e cleaning agent. However, surfactant cleaning fluids havealso been used successfully. Mount the apparatus firmly andconnect the trap to the vacuum. Warm the necessary amount ofcleaning acid in the beaker, place the pycnometer on theground joint, and evacuate by opening the stopcock to vacuum.Fill t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD121719932003E1STANDARDTESTMETHODFORDENSITYANDRELATIVEDENSITYSPECIFICGRAVITYOFLIQUIDSBYBINGHAMPYCNOMETER

链接地址:http://www.mydoc123.com/p-509464.html