ASTM D1203-2016 Standard Test Methods for Volatile Loss From Plastics Using Activated Carbon Methods《采用活性炭法测定塑料挥发性损失的标准试验方法》.pdf
《ASTM D1203-2016 Standard Test Methods for Volatile Loss From Plastics Using Activated Carbon Methods《采用活性炭法测定塑料挥发性损失的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1203-2016 Standard Test Methods for Volatile Loss From Plastics Using Activated Carbon Methods《采用活性炭法测定塑料挥发性损失的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1203 10D1203 16Standard Test Methods forVolatile Loss From Plastics Using Activated CarbonMethods1This standard is issued under the fixed designation D1203; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 These test methods cover the de
3、termination of volatile loss from a plastic material under defined conditions of time andtemperature, using activated carbon as the immersion medium.1.2 Two test methods are covered as follows:1.2.1 Test Method A, Direct Contact with Activated CarbonIn this test method the plastic material is in dir
4、ect contact with thecarbon. This test method is particularly useful in the rapid comparison of a large number of plastic specimens.1.2.2 Test Method B, Wire CageThis test method prescribes the use of a wire cage, which prevents direct contact between theplastic material and the carbon. By eliminatin
5、g the direct contact, the migration of the volatile components to the surroundingcarbon is minimized and loss by volatilization is more specifically measured.1.3 The values stated in SI units are to be regarded as the standard.1.4 This standard does not purport to address all of the safety concerns,
6、 if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1This standard is similar in content (not technically equivalent) to ISO 176.and ISO
7、176 address the same subject matter, but differ in technicalcontent.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsD1600 Terminology for Abbreviated Terms Relating to PlasticsE197 Specification for Enclosures and Ser
8、vicing Units for Tests Above and Below Room Temperature (Withdrawn 1981)3E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 Other Documents:ISO 176 Determination of the Loss of Plasticizers from Plastics by the Activated Carbon Method33. Terminology3
9、.1 DefinitionsDefinitions are in accordance with Terminologies D883 and D1600 unless otherwise indicated.4. Significance and Use4.1 The test methods are intended to be rapid empirical tests which have been found to be useful in the relative comparison ofmaterials having the same nominal thickness.1
10、These test methods are under the jurisdiction ofASTM Committee D20 on Plastics and are the direct responsibility of Subcommittee D20.15 on Thermoplastic Materials(Section D20.15.11 on Plasticizers).Current edition approved Nov. 1, 2010April 1, 2016. Published January 2011April 2016. Originally appro
11、ved in 1952. Last previous edition approved in 20032010 asD1203 94D1203 10.(2003). DOI: 10.1520/D1203-10. 10.1520/D1203-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, ref
12、er to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indicat
13、ion of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be cons
14、idered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1NOTE 2When the plastic material contains plasticizer, loss from the plastic is assumed to be
15、 primarily plasticizer. The effect of moisture is consideredto be negligible.4.2 Correlation with ultimate application for various plastic materials shall be determined by the user. To obtain accelerated teststhat more nearly approach actual service conditions, refer to Specification E197.5. Apparat
16、us5.1 BalanceAn accurate analytical balance, equipped with Class S weights or better.5.2 Oven or BathA thermostatically controlled oven or bath capable of maintaining the temperature to within 61C of thetest temperature, which normally will be in the range from 50 to 150C.5.3 ContainersMetal cans or
17、 wide-mouth screw-top jars, of cylindrical form, approximately 100 mm in diameter andapproximately 12 L in capacity.NOTE 3Pint paint cans work well.5.4 MicrometerA micrometer capable of measuring to the nearest 0.0025 mm for measuring the thickness of the testspecimens.5.5 Metal Cages (for Test Meth
18、od B)Wire cages constructed from approximately 30-mesh bronze gauze, in cylindrical form,having a diameter of 60 mm and a height of 6 mm, formed by soldering a strip of gauze at right angles to the periphery of a diskof bronze gauze. One of the bases acts as a lid.5.6 150 mL Beaker graduated in 10 m
19、L intervals.6. Material6.1 Activated Carbon, 614MeshIt has been found that different types and grades of activated carbon give differing results, thusmaking it necessary for the purchaser and the seller to agree on the same type and grade in order to obtain concordant results. Careshall be taken tha
20、t an airtight storage container is used for the activated carbon and that fresh material is used for each test. Theactivated carbon shall be screened through a 14-mesh screen immediately prior to use to eliminate fines.7. Test Specimens7.1 The test specimens shall be 5050 6 1 mm diameter disks made
21、of the plastic material to be tested. Three specimens of eachformulation shall be tested.7.2 Thickness of the test specimens shall be 0.25 6 0.025 mm.NOTE 4If another thickness is desired to be tested due to purchase specifications or other considerations, it shall be specified in the report.7.3 Dir
22、ect comparison of values between materials shall not be made unless all specimens so compared do not vary by morethan 610 % from a given nominal thickness.NOTE 5This precaution is necessary because of discrepancies that may arise due to edge effects, depletion of volatiles, and the fact that the per
23、centweight loss is an inverse function of thickness.8. Conditioning8.1 ConditioningCondition the test specimens at 23 6 2C and 50 6 10 % relative humidity for not less than 20 h prior totest in accordance with Procedure A of Practice D618. Preferably, specimens shall be suspended to assure free air
24、circulationamong the specimens. In cases of disagreement, the tolerances shall be 61C and 65 % relative humidity.9. ProcedureTest Method A, Direct Contact with Activated Carbon9.1 Weigh the conditioned specimens individually on the analytical balance and designate this weight as W1. Weight ofindivid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD12032016STANDARDTESTMETHODSFORVOLATILELOSSFROMPLASTICSUSINGACTIVATEDCARBONMETHODS 采用 活性炭 测定 塑料 挥发性

链接地址:http://www.mydoc123.com/p-509441.html