ASTM D1203-2010 Standard Test Methods for Volatile Loss From Plastics Using Activated Carbon Methods《用活性碳法测定塑料的挥发损失的标准试验方法》.pdf
《ASTM D1203-2010 Standard Test Methods for Volatile Loss From Plastics Using Activated Carbon Methods《用活性碳法测定塑料的挥发损失的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1203-2010 Standard Test Methods for Volatile Loss From Plastics Using Activated Carbon Methods《用活性碳法测定塑料的挥发损失的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1203 10Standard Test Methods forVolatile Loss From Plastics Using Activated CarbonMethods1This standard is issued under the fixed designation D1203; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods cover the determination o
3、f volatileloss from a plastic material under defined conditions of timeand temperature, using activated carbon as the immersionmedium.1.2 Two test methods are covered as follows:1.2.1 Test Method A, Direct Contact with ActivatedCarbonIn this test method the plastic material is in directcontact with
4、the carbon. This test method is particularly usefulin the rapid comparison of a large number of plastic specimens.1.2.2 Test Method B, Wire CageThis test method pre-scribes the use of a wire cage, which prevents direct contactbetween the plastic material and the carbon. By eliminating thedirect cont
5、act, the migration of the volatile components to thesurrounding carbon is minimized and loss by volatilization ismore specifically measured.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated
6、with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This standard is similar in content (not technically equivalent)to ISO 176.2. Referenced Documents2.1
7、 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsD1600 Terminology for Abbreviated Terms Relating toPlasticsE197 Specification for Enclosures and Servicing Units forTests Above and Below Room Temperature3E691 Practice for Conducting an Interlab
8、oratory Study toDetermine the Precision of a Test Method2.2 Other Documents:ISO 176 Determination of the Loss of Plasticizers fromPlastics by the Activated Carbon Method43. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nologies D883 and D1600 unless otherwise indicated.4. Signif
9、icance and Use4.1 The test methods are intended to be rapid empirical testswhich have been found to be useful in the relative comparisonof materials having the same nominal thickness.NOTE 2When the plastic material contains plasticizer, loss from theplastic is assumed to be primarily plasticizer. Th
10、e effect of moisture isconsidered to be negligible.4.2 Correlation with ultimate application for various plasticmaterials shall be determined by the user. To obtain acceleratedtests that more nearly approach actual service conditions, referto Specification E197.5. Apparatus5.1 BalanceAn accurate ana
11、lytical balance, equippedwith Class S weights or better.5.2 Oven or BathA thermostatically controlled oven orbath capable of maintaining the temperature to within 61C ofthe test temperature, which normally will be in the range from50 to 150C.5.3 ContainersMetal cans or wide-mouth screw-top jars,of c
12、ylindrical form, approximately 100 mm in diameter andapproximately12 L in capacity.NOTE 3Pint paint cans work well.1These test methods are under the jurisdiction of ASTM Committee D20 onPlastics and are the direct responsibility of Subcommittee D20.15 on ThermoplasticMaterials (Section D20.15.11 on
13、Plasticizers).Current edition approved Nov. 1, 2010. Published January 2011. Originallyapproved in 1952. Last previous edition approved in 2003 as D1203 94(2003).DOI: 10.1520/D1203-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm
14、.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th F
15、loor, New York, NY 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4 MicrometerA micrometer capable of measuring to thenearest 0.0025 mm fo
16、r measuring the thickness of the testspecimens.5.5 Metal Cages (for Test Method B)Wire cages con-structed from approximately 30-mesh bronze gauze, in cylin-drical form, having a diameter of 60 mm and a height of 6 mm,formed by soldering a strip of gauze at right angles to theperiphery of a disk of b
17、ronze gauze. One of the bases acts as alid.5.6 150 mL Beaker graduated in 10 mL intervals.6. Material6.1 Activated Carbon,614 MeshIt has been found thatdifferent types and grades of activated carbon give differingresults, thus making it necessary for the purchaser and theseller to agree on the same
18、type and grade in order to obtainconcordant results. Care shall be taken that an airtight storagecontainer is used for the activated carbon and that freshmaterial is used for each test. The activated carbon shall bescreened through a 14-mesh screen immediately prior to use toeliminate fines.7. Test
19、Specimens7.1 The test specimens shall be 50 mm diameter disks madeof the plastic material to be tested. Three specimens of eachformulation shall be tested.7.2 Thickness of the test specimens shall be 0.25 6 0.025mm.NOTE 4If another thickness is desired to be tested due to purchasespecifications or o
20、ther considerations, it shall be specified in the report.7.3 Direct comparison of values between materials shall notbe made unless all specimens so compared do not vary by morethan 610 % from a given nominal thickness.NOTE 5This precaution is necessary because of discrepancies thatmay arise due to e
21、dge effects, depletion of volatiles, and the fact that thepercent weight loss is an inverse function of thickness.8. Conditioning8.1 ConditioningCondition the test specimens at 23 62C and 50 6 10 % relative humidity for not less than 20 hprior to test in accordance with Procedure A of Practice D618.
22、Preferably, specimens shall be suspended to assure free aircirculation among the specimens. In cases of disagreement, thetolerances shall be 61C and 65 % relative humidity.9. ProcedureTest Method A, Direct Contact withActivated Carbon9.1 Weigh the conditioned specimens individually on theanalytical
23、balance and designate this weight as W1. Weight ofindividual specimens shall be within a tolerance of 610 %.9.2 Spread 120 cm3of activated carbon evenly on thebottom of a container. Place one specimen on top of theactivated carbon and cover it with 120 cm3of activated carbon.Place a second specimen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD12032010STANDARDTESTMETHODSFORVOLATILELOSSFROMPLASTICSUSINGACTIVATEDCARBONMETHODS 活性碳 测定 塑料 挥发 损失

链接地址:http://www.mydoc123.com/p-509440.html