1、Designation: D 1179 04Standard Test Methods forFluoride Ion in Water1This standard is issued under the fixed designation D 1179; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses ind
2、icates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods2cover the determination of fluorideion in water. The follo
3、wing two test methods are given:SectionsTest Method ADistillation 7 to 13Test Method BIon Selective Electrode 14 to 221.2 Test Method A covers the accurate measurement of totalfluoride in water through isolation of the fluoride by distillationand subsequent measurement in the distillate by use of th
4、e ionselective electrode (ISE) method. The procedure covers therange from 0.1 to 2.6 mg/L of fluoride.1.3 Test Method B covers the accurate measurement ofsimple fluoride ion in water by means of an ion selectiveelectrode. With this test method, distillation is eliminatedbecause the electrode is not
5、affected by the interferencescommon to colorimetric procedures. Concentrations of fluoridefrom 0.1 to 1000 mg/L may be measured.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
6、appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specificprecautionary statement, see 12.1.2.1.5 Former Test Method A, SPADNS Photometric Proce-dure, was discontinued. Refer to Appendix X1 for historicalinformation.2. Referenced
7、Documents2.1 ASTM Standards:3D 1066 Practice for Sampling SteamD 1129 Terminology Relating to WaterD 1192 Guide for Equipment for Sampling Water andSteam in Closed Conduits4D 1193 Specification for Reagent WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee
8、 D19 on WaterD 3370 Practices for Sampling Water from Closed ConduitsD 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water Analysis3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology D 1129.4. Significance and
9、Use4.1 Simple and complex fluoride ions are found in naturalwaters. Fluoride forms complexing ions with silicon, alumi-num, and boron. These complexes may originate from the useof fluorine compounds by industry.4.2 Fluoridation of drinking water to prevent dental caries ispracticed by a large number
10、 of communities in this country.Fluoride is monitored to assure that an optimum treatment levelof 1.4 to 2.4 mg/L, depending on the corresponding range ofambient temperatures of 32 to 10C, is maintained.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indi
11、cated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.5Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to pe
12、rmit its use without lessening the accuracy ofthe determination.5.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean Type I reagent waterconforming to Specification D 1193. Other reagent water typesmay be used provided it is first ascertained that the water i
13、s of1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.05 on InorganicConstituents in Water.Current edition approved July 1, 2004. Published July 2004. Originally approvedin 1951. Last previous edition approved in 1999 a
14、s D 1179 9p.2Bellack, E., “Simplified Fluoride Distillation Method, Journal of the Ameri-can Water Works Association, Vol 50, 1958, p. 530.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
15、 information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.5Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards
16、 for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.1*A Summary of Changes section appears at the end of this standard.Copyright. (C) ASTM International. 100 Barr Harbour Dr. P.O.
17、 box C-700 West Conshohocken, Pennsylvania 19428-2959, United StatesCopyright by ASTM Intl (all rights reserved); Sun Dec 20 20:08:08 EST 2009Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. No further reproductions authorized.sufficiently high purity to permit its use without ad
18、verselyaffecting the precision and bias of the test method. Type IIwater was specified at the time of round robin testing of thistest method.6. Sampling6.1 Collect the sample in accordance with Practice D 1066,Specification D 1192, or Practice D 3370, as applicable.TEST METHOD ADISTILLATION7. Scope7
19、.1 This test method is applicable to the accurate determi-nation of fluoride ion in water, including most wastewaters.This test method may not be applicable to concentrated brinesand oily wastes.7.2 This test method was tested on reagent water andwastewater. It is the users responsibility to ensure
20、the validityof this test method for waters of untested matrices.8. Summary of Test Method8.1 The fluoride is distilled as hydrofluosilicic acid and isdetermined by the ion selective electrode.9. Interferences9.1 In sample distillation, interferences may be experienceddue to the following factors.9.1
21、.1 Aluminum in excess of 300 mg/L and silicon dioxideas colloidal silica in excess of 400 mg/L will hold up in thecondenser to a certain extent, causing low results and acting asa positive interference for subsequent samples of lower fluoridecontent. In these cases, the condenser should be flushed w
22、ith300 to 400 mL of water and the washwater added to thedistillate. The distillate may then be diluted to 1.0 L. If theanalyst prefers, a smaller sample aliquot diluted to 300 mLmaybe selected for distillation.9.1.2 Sea water, brines, and generally samples of dissolvedsolids in excess of 2500 mg/L w
23、ill cause bumping in thedistillation flask. Dilution of the sample with fluoride-freewater to a lesser-dissolved solids concentration is an effectiveremedy to bumping.9.1.3 Samples containing oily matter which may result in atwo-phase distillate, an emulsion, or anything other than a cleardistillate
24、 may prevent accurate measurement of fluoride. Suchsamples should be extracted initially with a suitable solvent(such as ether, chloroform, benzene, and similar solvents) toremove the oily material, and then warmed on a steam bath toremove traces of the added solvent.10. Apparatus10.1 Distillation A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD11792004STANDARDTESTMETHODSFORFLUORIDEIONINWATER 水中 氟化物 离子 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-509400.html