ASTM D1118 D1118M-1995(2009)e1 Standard Test Method for Magnetic Rating of Asbestos Fiber and Asbestos Textiles《石棉纤维和石棉织物磁参数的标准试验方法》.pdf
《ASTM D1118 D1118M-1995(2009)e1 Standard Test Method for Magnetic Rating of Asbestos Fiber and Asbestos Textiles《石棉纤维和石棉织物磁参数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1118 D1118M-1995(2009)e1 Standard Test Method for Magnetic Rating of Asbestos Fiber and Asbestos Textiles《石棉纤维和石棉织物磁参数的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1118/D1118M 95 (Reapproved 2009)1Standard Test Method forMagnetic Rating of Asbestos Fiber and Asbestos Textiles1This standard is issued under the fixed designation D1118/D1118M; the number immediately following the designation indicates theyear of original adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was corrected editorially in March 2010.1. Scope1.1 This test method covers the proce
3、dure for the determi-nation of the magnetic rating of asbestos fiber and asbestostextile products. This test method is used primarily for testingasbestos insulating materials.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated inea
4、ch system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthris
5、ks for users and for those with whom they come into contact.In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Useof Chrysotile Asbestos: A Manual on Preventive and Con
6、trolMeasures.”21.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
7、 For specific safetyhazard, see 1.3.2. Referenced Documents2.1 ASTM Standards:3D123 Terminology Relating to TextilesD2100 Specification for Asbestos Textiles Used for Electri-cal Insulating PurposesD2590 Test Method for Sampling Chrysotile AsbestosD2946 Terminology for Asbestos and AsbestosCementPro
8、ductsD2947 Test Method for Screen Analysis of Asbestos FibersD3879 Test Method for Sampling Amphibole Asbestos4E11 Specification for Woven Wire Test Sieve Cloth and TestSieves2.2 ASTM Adjuncts:Metallic Analyzer Drawings53. Terminology3.1 For definitions of other textile terms used in this testmethod
9、, refer to Terminology D123. For terms relating toasbestos, refer to Terminology D2946.3.2 Definitions:3.2.1 asbestos fiber, nThe hydrous magnesium silicateserpentine mineral designated as chrysotile and having theempirical formula Mg3Si2O5(OH)4.3.2.2 atmosphere for testing textiles, nfor asbestos,
10、airmaintained at a relative humidity of 50 6 2 % at 70 6 2F 216 1C.3.2.3 magnetic rating (MR), nan empirical value reflect-ing the effect of the magnetic particles, such as magnetic ironcompounds, in asbestos material as measured by a magneticeffect analyzer. It is not a quantitative measure of the
11、magneticparticles in the material. Magnetic rating is affected by thequantity, concentration, particle size, shape, and orientation ofthe magnetic particles in the material.3.2.4 unit magnetic rating (1 MR), na calibrating standardwith an MR of one is defined as containing 0.18 g of U.S.National Ins
12、titute of Standards and Technology standardsample No. 29(a) or iron ore (magnetite) uniformly distributedover the space specified for a 10-g test specimen (19 mm 0.75in. diameter by 73 mm 2.875 in. long), by dispersion in amagnetically inert material. A10-g specimen has one unitmagnetic rating when
13、it produces a magnetic effect equivalentto that of 0.18 g of standard magnetite as described above.Conversely, a 10-g specimen producing a magnetic effect such1This test method is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of Subc
14、ommitteeC17.03 on Asbestos - Cement Sheet Products and Accessories.Current edition approved Nov. 1, 2009. Published March 2010. Originallyapproved in 1950. Last previous edition approved in 2004 as D1118 95(2004)2.DOI: 10.1520/D1118_D1118M-95R09E01.2Available from The Asbestos Institute, http:/ refe
15、renced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn. The last approved version of this historical standard is r
16、eferencedon www.astm.org.5Available from ASTM International Headquarters. Order Adjunct No.ADJD1118. Original adjunct produced in 1986.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.that the resulting induced current in the magnetic
17、 analyzergalvanometer is k times that of the 0.18 g of standard magnetiteas described above, would have a magnetic rating (MR) of k.4. Summary of Test Method4.1 The unknown electromagnetic effects of a sample ofasbestos-containing material is compared with those of areference standard in a magnetic
18、analyzer. The inductiveimbalance caused by the magnetic particles in the asbestossamples is amplified and measured with the magnetic analyzer.5. Significance and Use5.1 This test method for the determination of magneticrating is considered satisfactory for acceptance testing ofcommercial shipments o
19、f asbestos fibers, papers, felts, yarns,rovings, textile products, rigid sheet products, and granular orpowdered products.5.2 Magnetic rating is one of the measurements used fordetermining the suitability of an asbestos material for electricalinsulation.5.3 The electrical insulating properties of as
20、bestos materialsvary inversely with the magnetic rating. Therefore, a lowmagnetic iron content is required for good electrical insulating.5.4 The types of asbestos textiles classified by magneticrating are described in Specification D2100.6. Apparatus6.1 Magnetic AnalyzerEither the Mapes type analyz
21、er orthe Turner each operatortested 2 specimens of each sample. All 26 specimens of eachmaterial came from the same lot. The components of variancefor magnetic rating results expressed as coefficients of varia-tion were calculated to be:Single-operator component 4.4 % of the averageBetween-laborator
22、y component 9.4 % of the average7Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR:D13-1021.D1118/D1118M 95 (2009)1315.2 PrecisionFor the components of variance reported in15.1 two averages of observed values should be consideredsi
23、gnificantly different at the 95 % probability level if thedifference equals or exceeds the critical differences listedbelow.Critical Differences Percent of Grand Average for theConditions NotedABNumber of Observationsin Each AverageSingle-Operator Precision(Repeatability)Between-LaboratoryPrecision
24、(Reproducibility)1 12.2 28.72 8.6 27.45 5.5 26.610 3.8 26.3AThe critical differences were calculated using t = 1.960 which is based oninfinite degrees of freedom.BTo convert the values as listed above to units of measure, multiply the averageof the two specific sets of data being compared by the cri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD1118D1118M19952009E1STANDARDTESTMETHODFORMAGNETICRATINGOFASBESTOSFIBERANDASBESTOSTEXTILES 石棉 纤维

链接地址:http://www.mydoc123.com/p-509279.html