《ASTM D1042-2012 Standard Test Method for Linear Dimensional Changes of Plastics Caused by Exposure to Heat and Moisture《暴露于热湿条件下塑料线性尺寸变化的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1042-2012 Standard Test Method for Linear Dimensional Changes of Plastics Caused by Exposure to Heat and Moisture《暴露于热湿条件下塑料线性尺寸变化的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1042 06 D1042 12Standard Test Method forLinear Dimensional Changes of Plastics Under AcceleratedService ConditionsCaused by Exposure to Heat andMoisture1This standard is issued under the fixed designation D1042; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is designed to provide a means for measuring
3、in plastic specimens the dimensional changes resulting fromexposure to service conditions. In particular, this test method is suitable for measuring shrinkage or elongationsuch as shrinkageor expansion, developed under specific ovenheat and water conditionings.1.2 The values stated in SI units are t
4、o be regarded as standard. The values given in parentheses are mathematical conversionsto inch-pound units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the respo
5、nsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD59
6、47 Test Methods for Physical Dimensions of Solid Plastics Specimens3. Terminology3.1 Definitions: Definitions of terms applying to this test method appear in Terminology D883.4. Significance and Use4.1 This test method is intended only as a convenient test method for measurement of linear dimensiona
7、l changes in plasticssubjected to defined conditions of test as outlined in Sections 7 and 8.5. Apparatus5.1 Scriber, so constructed that two sharp needle points are rigidly separated by 100 6 0.2 mm. The scriber, as shown in Fig.1, consists of two sharp steel needles, approximately 1.5 mm in diamet
8、er. The needles are to be inserted in drilled holes with theiraxes parallel to each other and perpendicular to and intersecting the long axis of a stainless steel rigid rod or bar stock, 125 6 5mm in length. The needles points shall extend 6 6 2 mm beyond the supporting rod and are held in position
9、by setscrews insertedthrough the ends of the rod. The scriber shall be calibrated by scribing an arc onto an unconditioned sample and measuring thisinitial scribed distance with a calibrated caliper to the nearest 0.1 mm. Thickness of arc lines shall not exceed 0.02 mm.NOTE 2Phonograph needles may b
10、e used as a satisfactory scriber.5.2 Measuring Microscope, having a magnification of at least 20 and graduated to have a resolution of 0.01 mm.NOTE 3For more precise measurements, a micrometer microscope should be used.1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics an
11、d is the direct responsibility of Subcommittee D20.50 on Durability of Plastics.Current edition approved Sept. 1, 2006Nov. 15, 2012. Published September 2006December 2012. Originally published as D1042 49 T.T. Last previous editionD1042 01a.D1042 06. DOI: 10.1520/D1042-06.10.1520/D1042-12.2 For refe
12、renced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provid
13、e the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the st
14、andard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 Caliper, 6-in., with a readability of 0.01 mm a
15、nd an illuminated desk magnifier, 1.75 to 2.0 to assist with the placementof the caliper points onto the scribed lines5.4 Beaker, having a suitable size for the number of specimens to be evaluated and is constructed of a material that is stableunder the test conditions.5.5 Room or Conditioning Chamb
16、er, capable of being maintained at 23 6 2C and 50 6 5 % 10 % RH.5.6 Conditioning Oven, full draft air-circulating oven, capable of being maintained within 62C of the set temperature.5.7 Absorbent Material, cloth or paper suitable for drying.6. Test Specimens6.1 Specimens shall not be less than 110 m
17、m in length in the direction of test. The preferred specimen size is 125 6 5 mm inlength by 13 6 0.5 mm wide by 3.0 (-0.0 + 0.2) mm thick. Refer to Test Method D5947 for guidance on measuring physicaldimensions of solid plastic specimens.6.2 Three specimens shall be tested for each conditioning.6.3
18、Individual specimens shall be positioned vertically in the specified environment.NOTE 4A wire hook inserted in a hole drilled in one end of the specimen has been found acceptable.7. Conditioning and Exposure7.1 Preconditioning7.1.1 Unless otherwise specified in the appropriate material specification
19、, precondition specimens at 23 6 2C and 50 6 5 %10 % relative humidity for a minimum of 40 h prior to initial scribing.NOTE 5If moisture equilibrium is required prior to preconditioning, refer to the specific material specifications.7.1.2 After removal from the pre-conditioning environment, specimen
20、s shall be tested within 30 min.7.2 Method AWater Immersion7.2.1 Specimens shall be immersed in water maintained at 23 6 2C for 168 6 1 h.7.2.2 The specimens shall be wiped dry with the absorbent cloth after removal from the water and tested within 3 min.7.3 Method BOven Conditioning7.3.1 Specimens
21、shall be conditioned in an oven at 70 6 2C for 25 6 1 h.7.3.2 After removal from the oven, the specimens shall be tested within 3 min.7.4 Other conditionings for specific service conditions can be used if agreed upon by all parties.7.5 Conduct tests in a standard laboratory atmosphere of 23 6 2C and
22、 50 6 510 % relative humidity.8. Procedure8.1 Immediately following the preconditioning, scribe an arc of 100-mm radius on the surface of the test specimen. Press oneneedle firmly into the specimen to form a center for this and subsequent measurements. The other needle scribes the arc that isused as
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD10422012STANDARDTESTMETHODFORLINEARDIMENSIONALCHANGESOFPLASTICSCAUSEDBYEXPOSURETOHEATANDMOISTURE

链接地址:http://www.mydoc123.com/p-509149.html