ASTM C972-2018 Standard Test Method for Compression-Recovery of Tape Sealant.pdf
《ASTM C972-2018 Standard Test Method for Compression-Recovery of Tape Sealant.pdf》由会员分享,可在线阅读,更多相关《ASTM C972-2018 Standard Test Method for Compression-Recovery of Tape Sealant.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C972 00 (Reapproved 2011)C972 18Standard Test Method forCompression-Recovery of Tape Sealant1This standard is issued under the fixed designation C972; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a laboratory procedure for determining compression-recovery characteristics of tape sealant.1.2 Th
3、e values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish approp
4、riate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.NOTE 1There are no ISO standards similar or equivalent to this ASTM standard.1.4 This international standard was developed in accordance with internationally recognize
5、d principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C717 Terminology of Buildin
6、g Seals and Sealants3. Terminology3.1 DefinitionsFor definitions of terms used in this test method, refer to Terminology C717., standard conditions.4. Significance and Use4.1 Tape sealants are tacky, deformable solids used under compression between two or more surfaces of similar or dissimilarmateri
7、als in a variety of sealing applications. This procedure presents an indication of the compression recovery characteristics ofpreformed tapes.5. Apparatus5.1 Glass Plates, two, each 6.35 by 76.2 by 76.2 mm (0.25 by 3 by 3 in.).5.2 Steel Panels, two, cold-rolled, each 0.762 by 76.2 by 76.2 mm (0.03 b
8、y 3 by 3 in.).NOTE 2Substitutes such as aluminum, acrylic, acrylonitrile-butadiene-styrene (ABS), may be substituted for the plates (5.1) and panels (5.2).5.3 Compression Testing Machine, with a cross-head speed of 50 mm (2 in.)/min and capable of stopping at specified settings.NOTE 3Load values may
9、 differ when determined on screw-type versus spring-type test machines due to a drift past the desired stop in the spring-typemachine. It may be necessary to use shims to obtain the desired stop.5.4 Recorder, for recording compression loads in newtons (or pounds-force).5.5 Stop Watch, measuring in m
10、inutes and seconds.5.6 Gage or Rule, capable of measuring tape thickness to 0.025 mm or 0.001 in.1 This test method is under the jurisdiction of ASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on GeneralTest Methods.Current edition approved J
11、une 1, 2011June 1, 2018. Published August 2011July 2018. Originally approved in 1982. Last previous edition approved in 20062011 asC972 00 (2006).(2011). DOI: 10.1520/C0972-00R11.10.1520/C0972-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at
12、serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous versi
13、on. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM Internationa
14、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Test Specimen and Sample6.1 Conditioning:6.1.1 Condition the specimens for 24 h at 23 6 2C (73.4 6 3.6F) and 506 10 % relative humidity.standard conditions.6.1.2 Other conditioning parameters may be included as
15、 desired.6.2 Samples to be tested shall be taken from a roll or tape sealant after first removing and discarding approximately the first0.6 m (2 ft) of the roll.6.3 Tape sealant configuration should be approximately 9.53 by 9.53 by 76.2 mm (0.375 by 0.375 by 3 in.). The sample shouldbe re-extruded r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC9722018STANDARDTESTMETHODFORCOMPRESSIONRECOVERYOFTAPESEALANTPDF

链接地址:http://www.mydoc123.com/p-509017.html