ASTM C94 C94M-2009a Standard Specification for Ready-Mixed Concrete.pdf
《ASTM C94 C94M-2009a Standard Specification for Ready-Mixed Concrete.pdf》由会员分享,可在线阅读,更多相关《ASTM C94 C94M-2009a Standard Specification for Ready-Mixed Concrete.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C94/C94M 09aStandard Specification forReady-Mixed Concrete1This standard is issued under the fixed designation C94/C94M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers ready-mixed concrete as de-fined in 3.2.2. Requ
3、irements for quality of concrete shall beeither as hereinafter specified or as specified by the purchaser.In any case where the requirements of the purchaser differ fromthese in this specification, the purchasers specification shallgovern. This specification does not cover the placement,consolidatio
4、n, curing, or protection of the concrete afterdelivery to the purchaser.1.2 The values stated in either SI units, shown in brackets,or inch-pound units are to be regarded separately as standard.The values stated in each system may not be exact equivalents;therefore, each system shall be used indepen
5、dently of the other.Combining values from the two systems may result in non-conformance with the standard.1.3 As used throughout this specification the manufacturerproduces ready-mixed concrete. The purchaser buys ready-mixed concrete.1.4 The text of this standard references notes and footnoteswhich
6、 provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.5 This standard does not purport to address all the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this st
7、andard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementi-tious mixtures are caustic and may cause chemical burns toskin and tissue upon prolonged use.2)2. Referenced Documents2.1 ASTM Standards:3
8、C31/C31M Practice for Making and Curing Concrete TestSpecimens in the FieldC33 Specification for Concrete AggregatesC39/C39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC125 Terminology Relating to Concrete and Concrete Ag-gregatesC138/C138M Test Method for Density (Unit W
9、eight),Yield, and Air Content (Gravimetric) of ConcreteC143/C143M Test Method for Slump of Hydraulic-CementConcreteC150 Specification for Portland CementC172 Practice for Sampling Freshly Mixed ConcreteC173/C173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric MethodC231 Test
10、Method for Air Content of Freshly Mixed Con-crete by the Pressure MethodC260 Specification for Air-Entraining Admixtures for Con-creteC330 Specification for Lightweight Aggregates for Struc-tural ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC567 Test Method for Determining Den
11、sity of StructuralLightweight ConcreteC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC637 Specification for Aggregates for Radiation-ShieldingConcreteC989 Specification for Slag Cement for Use in Concreteand
12、MortarsC1017/C1017M Specification for Chemical Admixtures forUse in Producing Flowing ConcreteC1064/C1064M Test Method for Temperature of FreshlyMixed Hydraulic-Cement ConcreteC1077 Practice for Laboratories Testing Concrete and Con-crete Aggregates for Use in Construction and Criteria forLaboratory
13、 EvaluationC1157 Performance Specification for Hydraulic CementC1240 Specification for Silica Fume Used in CementitiousMixtures1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.40 on Ready-Mixed
14、Concrete.Current edition approved Nov. 1, 2009. Published December 2009. Originallyapproved in 1933. Last previous edition approved in 2009 as C94/C94M09. DOI:10.1520/C0094_C0094M-09a.2See Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol. 04.
15、02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this
16、standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.C1602/C1602M Specification for Mixing Water Used in theProduction of Hydraulic Cement ConcreteC1611/C1611M Test Method for Slump Flow of Self-Consolidating Concrete2.2 ACI Docum
17、ents:4CP-1 Technician Workbook for ACI Certification of Con-crete Field Testing TechnicianGrade I211.1 Standard Practice for Selecting Proportions for Nor-mal, Heavyweight, and Mass Concrete211.2 Standard Practice for Selecting Proportions for Struc-tural Lightweight Concrete301 Standard Specificati
18、ons for Structural Concrete305R Hot Weather Concreting306R Cold Weather Concreting318 Building Code Requirements for Structural Concreteand Commentary2.3 Other Documents:Bureau of Reclamation Concrete Manual53. Terminology3.1 Definitions:The terms used in this specification are defined in Terminol-o
19、gy C125.3.2 Definitions of Terms Specific to This Standard:3.2.1 concrete, central-mixed, nconcrete mixed com-pletely in a stationary mixer.3.2.2 concrete, ready-mixed, nconcrete manufactured anddelivered to a purchaser in a fresh state.3.2.3 concrete, shrink-mixed, nconcrete partially mixed ina sta
20、tionary mixer with mixing completed in a truck mixer.3.2.4 concrete, truck-mixed, nconcrete completely mixedin a truck mixer.4. Basis of Purchase4.1 The basis of purchase shall be a cubic yard or cubicmetre of fresh concrete as discharged from the transportationunit.4.2 The volume of fresh concrete
21、in a given batch shall bedetermined from the total mass of the batch divided by thedensity of the concrete. The total mass of the batch shall bedetermined as the net mass of the concrete in the batch asdelivered, including the total mixing water as defined in 9.3.The density shall be determined in a
22、ccordance with TestMethod C138/C138M. The yield shall be determined as theaverage of at least three measurements, one from each of threedifferent transportation units sampled in accordance withPractice C172.NOTE 1It should be understood that the volume of hardened concretemay be, or appear to be, le
23、ss than expected due to waste and spillage,over-excavation, spreading forms, some loss of entrained air, or settlementof wet mixtures, none of which are the responsibility of the producer.5. Materials5.1 In the absence of designated applicable materials speci-fications, the following materials speci
24、fications shall be used:5.2 Cementitious Materials5.2.1 Hydraulic CementHydraulic cement shall conformto Specification C150, Specification C595, or SpecificationC1157.5.2.2 Supplementary Cementitious MaterialsCoal fly ashor natural pozzolans shall conform to Specification C618.Ground granulated blas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC94C94M2009ASTANDARDSPECIFICATIONFORREADYMIXEDCONCRETEPDF

链接地址:http://www.mydoc123.com/p-508891.html