ASTM C90-2011a Standard Specification for Loadbearing Concrete Masonry Units《承重混凝土圬工单位标准规格》.pdf
《ASTM C90-2011a Standard Specification for Loadbearing Concrete Masonry Units《承重混凝土圬工单位标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C90-2011a Standard Specification for Loadbearing Concrete Masonry Units《承重混凝土圬工单位标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C90 11aStandard Specification forLoadbearing Concrete Masonry Units1This standard is issued under the fixed designation C90; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers hollow and solid (see 5.3 and5.4) concrete
3、masonry units made from hydraulic cement,water, and mineral aggregates with or without the inclusion ofother materials. There are three classes of concrete masonryunits: (1) normal weight, (2) medium weight, and (3) light-weight. These units are suitable for both loadbearing andnonloadbearing applic
4、ations.1.2 Concrete masonry units covered by this specification aremade from lightweight or normal weight aggregates, or both.1.3 The text of this specification references notes andfootnotes which provide explanatory material. These notes andfootnotes (excluding those in tables and figures) shall no
5、t beconsidered as requirements of the standard.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.NOTE 1When particular features are des
6、ired such as surface texturesfor appearance or bond, finish, color, or particular properties such asdensity classification, higher compressive strength, fire resistance, thermalperformance or acoustical performance, these features should be specifiedseparately by the purchaser. Suppliers should be c
7、onsulted as to theavailability of units having the desired features.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC140 Test Methods for Sampling and Testing ConcreteMasonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Light
8、weight Aggregates for Con-crete Masonry UnitsC426 Test Method for Linear Drying Shrinkage of ConcreteMasonry UnitsC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC989 Specification for Slag Cement for Use in C
9、oncreteand MortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology of MasonryC1314 Test Method for Compressive Strength of MasonryPrismsE519 Test Method for Diagonal Tension (Shear) in MasonryAssemblagesE72 Test Methods of Conducting Strength Tests of Panelsfor Building Construc
10、tion3. Terminology3.1 Terminology defined in Terminology C1232 shall applyfor this specification.4. Materials4.1 Cementitious MaterialsMaterials shall conform to thefollowing applicable specifications:4.1.1 Portland CementSpecification C150.4.1.2 Modified Portland CementPortland cement con-forming t
11、o Specification C150, modified as follows:(1) LimestoneIf calcium carbonate is added to thecement, the CaCO3content shall not be less than 85 %.(2) Limitation on Insoluble Residue1.5 %.(3) Limitation on Air Content of MortarVolume percent,22 % max.(4) Limitation on Loss on Ignition7 %.4.1.3 Blended
12、Hydraulic CementsSpecification C595.4.1.4 Hydraulic CementSpecification C1157.4.1.5 PozzolansSpecification C618.4.1.6 Blast Furnace Slag CementSpecification C989.4.2 AggregatesAggregates shall conform to the followingspecifications, except that grading requirements shall notnecessarily apply:1This s
13、pecification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.03 on Concrete Masonry Units and Related Units.Current edition approved June 1, 2011. Published June 2011. Originallyapproved in 1931. Last previous edition a
14、pproved in 2011 as C90 11. DOI:10.1520/C0090-11A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary
15、of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSpecification C331.4.3 Other ConstituentsAir-entraining
16、 agents, coloringpigments, integral water repellents, finely ground silica, andother constituents shall be previously established as suitable foruse in concrete masonry units and shall conform to applicableASTM standards or shall be shown by test or experience not tobe detrimental to the durability
17、of the concrete masonry unitsor any material customarily used in masonry construction.5. Physical Requirements5.1 At the time of delivery to the purchaser, units shallconform to the physical requirements prescribed in Table 1 andTable 2. All units shall be sound and free of cracks or otherdefects th
18、at interfere with the proper placement of the unit orsignificantly impair the strength or permanence of the construc-tion. Minor cracks, incidental to the usual method of manufac-ture or minor chipping resulting from customary methods ofhandling in shipment and delivery, are not grounds for rejec-ti
19、on.NOTE 2Higher compressive strengths than those listed in Table 2 maybe specified where required by design. Consult with suppliers to determineavailability of units of higher compressive strength.NOTE 3Oven-dry densities of concrete masonry units generally fallwithin the range of 85 to 145 lbf/ft3(
20、1360 to 2320 kg/m3). Becauseavailable densities will vary, suppliers should be consulted before speci-fying project requirements.5.1.1 When higher compressive strengths than those listedin Table 2 are specified, the tested average net area compres-sive strength of three units shall equal or exceed t
21、he specifiedcompressive strength, and the tested individual unit net areacompressive strength of all three units shall exceed 90 % of thespecified compressive strength.5.2 At the time of delivery to the purchaser, the linearshrinkage of units shall not exceed 0.065 %.NOTE 4The purchaser is the publi
22、c body or authority, association,corporation, partnership, or individual entering into a contract or agree-ment to purchase or install, or both, concrete masonry units. The time ofdelivery to the purchaser is FOB plant when the purchaser or thepurchasers agent transports the concrete masonry units,
23、or at the timeunloaded at the worksite if the manufacturer or the manufacturers agenttransports the concrete masonry units.5.3 Hollow Units:5.3.1 Face shell thickness (tfs) and web thickness (tw) shallconform to the requirements prescribed in Table 1.NOTE 5Web thickness (tw) not conforming to the re
24、quirementsprescribed in Table 1 may be approved, provided equivalent structuralcapability has been established when tested in accordance with theapplicable provisions of Test Methods E72, C1314, E519, or otherapplicable tests and the appropriate design criteria developed is inaccordance with applica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC902011ASTANDARDSPECIFICATIONFORLOADBEARINGCONCRETEMASONRYUNITS 承重 混凝土 单位 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-508712.html