ASTM C884 C884M-1998(2010) Standard Test Method for Thermal Compatibility Between Concrete and an Epoxy-Resin Overlay《混凝土和环氧树脂涂层间热容性的标准试验方法》.pdf
《ASTM C884 C884M-1998(2010) Standard Test Method for Thermal Compatibility Between Concrete and an Epoxy-Resin Overlay《混凝土和环氧树脂涂层间热容性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C884 C884M-1998(2010) Standard Test Method for Thermal Compatibility Between Concrete and an Epoxy-Resin Overlay《混凝土和环氧树脂涂层间热容性的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C884/C884M 98 (Reapproved 2010)Standard Test Method forThermal Compatibility Between Concrete and an Epoxy-Resin Overlay1This standard is issued under the fixed designation C884/C884M; the number immediately following the designation indicates the yearof original adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test
3、method covers the determination of whichepoxy-resin formulations are subject to debonding when usedas overlays for concrete when the combination of the two issubjected to temperature changes that may be met in the field.1.2 The values stated in either inch-pound units or SI unitsare to be regarded s
4、eparately as standard. Within the text, theSI units are shown in brackets. The values stated in eachsystem are not exact equivalents; therefore, each system shallbe used independently of the other. Combining values from thetwo systems may result in nonconformance with the specifi-cation.1.3 This sta
5、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. A specific hazardstatement
6、 is given in Section 7.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC150 Specification for Portland CementC260 Specification for Air-Entraining Admixtures for Con-creteC672/C672M Test Method for Scaling Resistance of Con-crete Surfaces Exposed to Deicing Chemic
7、alsC778 Specification for SandC881/C881M Specification for Epoxy-Resin-Base BondingSystems for Concrete3. Summary of Test Method3.1 A layer of epoxy-sand mortar is applied to a slab ofcured and dried concrete.After the epoxy has cured, the sampleis subjected to five cycles of temperature change betw
8、een 77 F25 C and 6 F 21 C. Cracks near the bond linebetween the concrete and the epoxy mortar constitute failure ofthe test.4. Significance and Use4.1 This test method applies to materials used in makingepoxy-mortar overlays for concrete pavement. When debond-ing occurs between the overlay and the p
9、avement, the materialis unsuitable.5. Apparatus5.1 Molds, in conformance with Test Method C672/C672M.5.2 Freezer, in conformance with Test Method C672/C672M, except that the temperature of the freezer shall be 66 3 F 21 6 2 C.5.3 Retaining strips, to retain the epoxy-mortar overlay.Pieces of wood or
10、 steel that can be attached to the 12 by 12 by3-in. 300 by 300 by 75-mm concrete block so as to enclosecompletely the top surface of the block and rise above it auniform distance of 0.5 in. 15 mm.6. Materials6.1 Portland Cement, Type I or Type II, meeting therequirements of Specification C150.6.2 St
11、andard Sand, meeting the requirements of Specifica-tion C778.6.3 AggregatesFine and coarse aggregate meeting therequirements of Specification C33. The coarse aggregate shallbe durable under freezing exposure and shall have a maximumsize of 1 in. 25 mm. The fine aggregate shall be a naturalsand.1This
12、 test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.25 on Organic Materials for Bonding.Current edition approved Dec. 15, 2010. Published March 2011. Originallyapproved in 1978. Last previous edition appr
13、oved in 1998 as C884/C884M98(2005). DOI: 10.1520/C0884_C0884M-98R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM w
14、ebsite.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.4 Air-Entraining Admixture, meeting the requirements ofSpecification C260.7. Hazards7.1 WarningEpoxy resins contain irritants, especially tothe skin, eyes, and respiratory syst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC884C884M19982010STANDARDTESTMETHODFORTHERMALCOMPATIBILITYBETWEENCONCRETEANDANEPOXYRESINOVERLAY 混凝土

链接地址:http://www.mydoc123.com/p-508658.html