ASTM C872-2010(2015) Standard Test Method for Lead and Cadmium Release from Porcelain Enamel Surfaces《从搪瓷表面析出铅及镉的标准试验方法》.pdf
《ASTM C872-2010(2015) Standard Test Method for Lead and Cadmium Release from Porcelain Enamel Surfaces《从搪瓷表面析出铅及镉的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C872-2010(2015) Standard Test Method for Lead and Cadmium Release from Porcelain Enamel Surfaces《从搪瓷表面析出铅及镉的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C872 10 (Reapproved 2015)Standard Test Method forLead and Cadmium Release from Porcelain EnamelSurfaces1This standard is issued under the fixed designation C872; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method covers the precise determination of lead or cadmium extracted by acetic acid fromporcelain enamel
3、 surfaces. The procedure of extraction may be expected to accelerate the release oflead or cadmium and to serve, therefore, as a severe test that is unlikely to be matched under actualconditions of usage.1. Scope1.1 This test method covers the precise determination oflead and cadmium extracted by ac
4、etic acid from porcelainenamel surfaces.1.2 Values stated in SI units are to be regarded as thestandard. Inch-pound units are given for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of th
5、is standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C738 Test Method for Lead and Cadmium Extracted fromGlazed Ceramic SurfacesD1193 Specification for Reagent Water3. Summ
6、ary of Test Method3.1 The lead and cadmium extracted from the article undertest by acetic acid at 20 to 24C (68 to 75F) after 24 h ofleaching are measured by atomic absorption spectrophotometryusing a specific hollow cathode lamp for lead and cadmiumrespectively.4. Significance and Use4.1 The determ
7、ination of lead and cadmium release fromporcelain enamel surfaces was formerly of interest only tomanufacturers of porcelain enamel cookware and similar foodservice products. Food contact surfaces of these container-typeproducts have been evaluated using a test procedure similar toTest Method C738.
8、Recently, however, there has been a need tomeasure lead and cadmium release from flat or curved porce-lain enamel surfaces that are not capable of being evaluated bya test similar to Test Method C738.5. Interferences5.1 Since a specific hollow cathode lamp for lead andcadmium is used, there are no i
9、nterferences.6. Apparatus6.1 Atomic Absorption Spectrophotometer , equipped with a102-mm (4-in.) single slot or Boling burner head and digitalconcentration readout attachment (DCR) if available.3Thisinstrument should have a sensitivity of about 0.5 mg/L of leadfor 1 % absorption and a sensitivity of
10、 about 0.03 mg/L ofcadmium for 1 % absorption. The operating conditions asspecified in the instrument manufacturers analytical methodsmanual shall be used.NOTE 1ppm, mg/L, and g/mL are equivalent units.6.2 Hollow Cathode Lead Lamp, with wavelength set at283.3 or 217.0 nm.6.3 Hollow Cathode Cadmium L
11、amp, with wavelength setat 228.8 nm.6.4 Glassware of chemically resistant borosilicate glass, tomake reagents and solutions.1This test method is under the jurisdiction ofASTM Committee B08 on Metallicand Inorganic Coatings and is the direct responsibility of Subcommittee B08.12 onMaterials for Porce
12、lain Enamel and Ceramic-Metal Systems.Current edition approved May 1, 2015. Published June 2015. Originallyapproved in 1977. Last previous edition approved in 2010 as C872 10. DOI:10.1520/C0872-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
13、e at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Perkin-Elmer model 303 and Jarrell-Ash model 82-546 have been foundsuitable for this determination.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
14、700, West Conshohocken, PA 19428-2959. United States16.5 Test Cell, suitable for the containment of the leachingsolution on a flat porcelain enamel surface. A cell that hasproved suitable for this purpose is shown in Fig. 1.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all
15、 tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades may beused provided it is first ascertained that the reagent is ofsu
16、fficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled water (seeSpecification D1193).7.3 Acetic Acid (4 % by volume)Mix 1 volume of glacialacetic acid with 24
17、 volumes of water.4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United
18、 States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.Metric Equivalents for ApparatusDimensions (Fig. 1)in. mm18 3.214 6.438 9.5114 31.812532 45.2214 57.22.31 58.72.5 63.54 101.64116 103.2418 104.8512 139.7FIG. 1 Suitable Test CellC872 10 (2015)2NOTE
19、2A reagent blank shall be run each time a 4 % acid solution isprepared.7.4 Detergent RinseAdd 15 g of suitable alkaline deter-gent5to 1 gal (3.79 L) of lukewarm tap water.7.5 Lead Nitrate Solution (1000 mg Pb/L)Dissolve 1.598g of lead nitrate (Pb(NO3)2) in 4 % acetic acid and dilute to 1L with 4 % a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC87220102015STANDARDTESTMETHODFORLEADANDCADMIUMRELEASEFROMPORCELAINENAMELSURFACES 搪瓷 表面 析出 标准 试验

链接地址:http://www.mydoc123.com/p-508613.html