ASTM C872-1989(2005) Standard Test Method for Lead and Cadmium Release from Porcelain Enamel Surfaces《从搪瓷表面析出铅及镉的试验方法》.pdf
《ASTM C872-1989(2005) Standard Test Method for Lead and Cadmium Release from Porcelain Enamel Surfaces《从搪瓷表面析出铅及镉的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C872-1989(2005) Standard Test Method for Lead and Cadmium Release from Porcelain Enamel Surfaces《从搪瓷表面析出铅及镉的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 872 89 (Reapproved 2005)Standard Test Method forLead and Cadmium Release from Porcelain EnamelSurfaces1This standard is issued under the fixed designation C 872; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the precise determination oflead and cadmium extracted by acetic acid from porcelainena
3、mel surfaces.1.2 Values stated in SI units are to be regarded as thestandard. Inch-pound units are given for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish ap
4、pro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 738 Test Method for Lead and Cadmium Extracted fromGlazed Ceramic SurfacesD 1193 Specification for Reagent Water3. Summary of Test Method3.1 The
5、 lead and cadmium extracted from the article undertest by acetic acid at 20 to 24C (68 to 75F) after 24 h ofleaching are measured by atomic absorption spectrophotometryusing a specific hollow cathode lamp for lead and cadmiumrespectively.4. Significance and Use4.1 The determination of lead and cadmi
6、um release fromporcelain enamel surfaces was formerly of interest only tomanufacturers of porcelain enamel cookware and similar foodservice products. Food contact surfaces of these container-typeproducts have been evaluated using a test procedure similar toTest Method C 738. Recently, however, there
7、 has been a needto measure lead and cadmium release from flat or curvedporcelain enamel surfaces that are not capable of beingevaluated by a test similar to Test Method C 738.5. Interferences5.1 Since a specific hollow cathode lamp for lead andcadmium is used, there are no interferences.6. Apparatus
8、6.1 Atomic Absorption Spectrophotometer, equipped with a102-mm (4-in.) single slot or Boling burner head and digitalconcentration readout attachment (DCR) if available.3Thisinstrument should have a sensitivity of about 0.5 mg/L of leadfor 1 % absorption and a sensitivity of about 0.03 mg/L ofcadmium
9、 for 1 % absorption. The operating conditions asspecified in the instrument manufacturers analytical methodsmanual shall be used.NOTE 1ppm, mg/L, and g/mL are equivalent units.6.2 Hollow Cathode Lead Lamp, with wavelength set at283.3 or 217.0 nm.6.3 Hollow Cathode Cadmium Lamp, with wavelength setat
10、 228.8 nm.6.4 Glassware of chemically resistant borosilicate glass, tomake reagents and solutions.6.5 Test Cell, suitable for the containment of the leachingsolution on a flat porcelain enamel surface. A cell that hasproved suitable for this purpose is shown in Fig. 1.7. Reagents7.1 Purity of Reagen
11、tsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades may be1This test method
12、 is under the jurisdiction ofASTM Committee B08 on Metallicand Inorganic Coatings and is the direct responsibility of Subcommittee B08.12 onMaterials for Porcelain Enamel and Ceramic-Metal Systems.Current edition approved Sept. 15, 2005. Published September 2005. Original-lyapproved in 1977. Last pr
13、evious edition approved in 1999 as C 872 89 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Perkin-El
14、mer model 303 and Jarrell-Ash model 82-546 have been foundsuitable for this determination.4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standard
15、s for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.used provid
16、ed it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled water (seeSpecification D 1193).7.3 Acetic Acid (4 %
17、by volume)Mix 1 volume of glacialacetic acid with 24 volumes of water.NOTE 2A reagent blank shall be run each time a 4 % acid solution isprepared.7.4 Detergent RinseAdd 15 g of suitable alkaline deter-gent5to 1 gal (3.79 L) of lukewarm tap water.7.5 Lead Nitrate Solution (1000 mg Pb/L)Dissolve 1.598
18、g of lead nitrate (Pb(NO3)2) in 4 % acetic acid and dilute to 1L with 4 % acetic acid. Commercially available standard leadsolutions may also be used.5A suitable detergent is Calgonite, manufactured by the Calgon Corp., Box1436, Pittsburgh, PA 15230, and is available in most supermarkets.Metric Equi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便