ASTM C862-2002 Standard Practice for Preparing Refractory Concrete Specimens by Casting《浇铸法制备耐火混凝土样件的标准实施规程》.pdf
《ASTM C862-2002 Standard Practice for Preparing Refractory Concrete Specimens by Casting《浇铸法制备耐火混凝土样件的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C862-2002 Standard Practice for Preparing Refractory Concrete Specimens by Casting《浇铸法制备耐火混凝土样件的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 862 02Standard Practice forPreparing Refractory Concrete Specimens by Casting1This standard is issued under the fixed designation C 862; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice covers the mixing, casting and curing ofm
3、onolithic refractory concrete specimens for use in furthertesting. It does not apply to monolithic castable refractoriesintended primarily for gunning applications.1.2 The values given in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3
4、Various specimen sizes are required for specific testmethods. Refer to these test methods to determine the size andnumber of specimens, which will be required from the sample.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibi
5、lity of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 133 Test Methods for Cold Crushing Strength and Modu-lus of Rupture of Refractories2C 192 Practi
6、ce for Making and Curing Concrete Test Speci-mens in the Laboratory33. Significance and Use3.1 This practice is used to standardize mixing, moldconditions, placement and curing of refractory concrete speci-mens to be used for testing and evaluation under other testmethods.3.2 This practice standardi
7、zes laboratory conditions forproducing refractory concrete specimens to minimizelaboratory-to-laboratory variation and does not attempt toduplicate the conditions of field installations.3.3 This practice can be used for the preparation of speci-mens used in referee testing.4. Apparatus and Condition
8、s4.1 Laboratory ConditionsThe laboratory ambient shouldbe controlled between 70 and 80F (20 and 27C) and from 40to 60 % relative humidity for preconditioning materials andequipment, batching and mixing casting test specimens, strip-ping molds, and testing specimens. Report laboratory tempera-ture an
9、d relative humidity with physical test results if otherthan specified.4.2 BalancesAppropriately sized scales having a sensitiv-ity of 0.2 % of the related batch size.4.3 Castable MixersAn electrically operated mechanicalmixer4(Fig. 1) may be used for preparing castable batches forcasting specimens.
10、A 2-ft3(56.6-dm3) mixing bowl or a 212-ft3(70.8-dm3) concrete mixer has sufficient capacity to mix about1ft3of refractory castable. The smallest batches required forcasting 1-in. (25-mm) square bars can be mixed in a 0.10-ft3(2.83-dm3) bowl available with bench mixers. Size mixingbowl to contain fro
11、m 50 to 75 % volume loading with the drybatch.NOTE 1Castable water requirement variation becomes more signifi-cant as dry volume loadings drop below 40 % because the water requiredto wet the bowl surfaces changes more rapidly with decreasing volumeloadings.4.4 Gang MoldsMetal, two or more sets, as s
12、hown inFigs. 2 and 3, for casting specimens to the size required forspecific physical property testing (see Note 8). The front plateof the mold illustrated is held in place by quick-release clamps(50-lbf (222-N) pull exerted by each clamp) that permitemptying the mold by releasing the clamps and tap
13、ping the leftend of the front plate, thereby parting all of the separator platesand loosening the cast-test specimens.51This practice is under the jurisdiction ofASTM Committee C08 on Refractories, and is the direct responsibility of Subcommittee C08.09 on Monolithic Refracto-ries.Current edition ap
14、proved Nov 10, 2002. Published June 2003. Originallyapproved in 1977. Last previous edition approved in 2001 as C 862 01.2Annual Book of ASTM Standards, Vol 15.01.3Annual Book of ASTM Standards, Vol 04.02.4Mixers having various capacities are available from the Hobart ManufacturingCo., Troy, OH and
15、have been found to be suitable for this purpose.5A list of materials and notes on construction of the 9-in. (230 mm) straight-brick gang molds are available at a nominal charge from the Orton RefractoryResearch Center, Westerville, Ohio.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C7
16、00, West Conshohocken, PA 19428-2959, United States.4.4.1 As an alternative design for 1 in. (25-mm) square bars,individual molds may be constructed out of 16-gage (1.588-mm) stainless-steel sheet and ganged in groups of five with alarge rubber band on a glass base-plate.4.4.2 There are commercially
17、 available molds from con-crete testing suppliers and other sources. Molds may bereusable or for single use. Molds must be water tight, rigid, andremovable.4.5 CalipersSuitable for measuring internal longitudinalmold dimensions and subsequent specimen length size to thenearest 0.01 in. (0.25 mm).4.6
18、 Mold LubricantEither paraffin or silicone-based oilscan be used as a release or parting agent for coating molds.Other mold lubricants such as vegetable oils and petroleum-based oils can be used.4.7 Strike-Off Bar20-in. (510-mm) length of steel barstock, 112 by316 in. (38 by 5 mm).4.8 ThermometerDig
19、ital or dial-type, metal, with a rangefrom 0 to 180F (18 to 80C).4.9 TimerSignal-type, for periods up to 5 min. (A stopwatch may be used.)4.10 Trowels6 in. pointing and 2 by 6 in. (51 by 152 mm)square, and a 10-in. (254-mm) stainless-steel spatula.4.11 OvenFor curing and drying, preferably forced dr
20、aftrather than natural convection, with a capacity to hold aminimum of one sample group of specimens (12 by 12 by 12in.) (30 by 30 by 30-mm.).4.12 Heavy Rubber GlovesFor castables containing metalfibers.4.13 ScoopFor transferring the castable from the mixer tothe mold more easily.4.14 Vibration Tabl
21、eFor use in 6.4.2.64.15 Sample SplittersThe sample splitter opening shall bea minimum of 3 times the maximum grain size.4.16 Mixing BoxBox of suitable size and strength to handmix lightweight castable. Inside surface of box should not bewater absorbent. Fig. 4 is a possible solution.4.17 HoeHand-hel
22、d hoe for mixing lightweight castable.4.18 Humidity CabinetA cabinet capable maintaining arelative humidity of greater then 95 % within 90-95F (32-35C) is optional.5. Sampling5.1 Asufficient amount of dry castable should be batched tooverfill the gang molds by at least a 10 %. This shouldeliminate t
23、he use of both trailings and scrapings of wetcastable.5.2 At the time of use, the dry sample should be between 70and 80F (20 and 27C). Measure the temperature (Note 2)byinserting the full length of the thermometer stem into thematerial until the reading is constant. Record and report withphysical te
24、st results.NOTE 2It is recommended that in referee tests involving more thanone laboratory, the temperature of the dry refractory concrete mix andmixing water be within the specified range, in all laboratories.5.3 The contents of the container should be thoroughlymixed dry prior to water addition. W
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC8622002STANDARDPRACTICEFORPREPARINGREFRACTORYCONCRETESPECIMENSBYCASTING 浇铸 法制 耐火 混凝土 样件 标准 实施 规程

链接地址:http://www.mydoc123.com/p-508575.html