ASTM C830-2000(2006)e1 Standard Test Methods for Apparent Porosity Liquid Absorption Apparent Specific Gravity and Bulk Density of Refractory Shapes by Vacuum Pressure《用真空压力法测定成型耐火.pdf
《ASTM C830-2000(2006)e1 Standard Test Methods for Apparent Porosity Liquid Absorption Apparent Specific Gravity and Bulk Density of Refractory Shapes by Vacuum Pressure《用真空压力法测定成型耐火.pdf》由会员分享,可在线阅读,更多相关《ASTM C830-2000(2006)e1 Standard Test Methods for Apparent Porosity Liquid Absorption Apparent Specific Gravity and Bulk Density of Refractory Shapes by Vacuum Pressure《用真空压力法测定成型耐火.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 830 00 (Reapproved 2006)1Standard Test Methods forApparent Porosity, Liquid Absorption, Apparent SpecificGravity, and Bulk Density of Refractory Shapes by VacuumPressure1This standard is issued under the fixed designation C 830; the number immediately following the designation indicat
2、es the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits of measure statement was added editorially in
3、April 2009.1. Scope1.1 These test methods cover the determination of thefollowing properties of refractory shapes:1.1.1 Apparent porosity,1.1.2 Liquid absorption,1.1.3 Apparent specific gravity, and1.1.4 Bulk density.1.2 These test methods are applicable to all refractoryshapes except those that che
4、mically react with both water andmineral spirits. When testing a material capable of hydration orother chemical reaction with water but which does not chemi-cally react with mineral spirits, mineral spirits is substituted forwater and appropriate corrections for the density differencesare applied wh
5、en making calculations.1.3 UnitsThe values stated in inch-pound units are to beregarded as standard. The values given in parentheses aremathematical conversions to SI units that are provided forinformation only and are not considered standard.1.3.1 ExceptionThe apparatus used in this standard isonly
6、 available in SI units.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
7、 to use.NOTE 1Test Methods C20cover procedures for testing properties ofrefractories that are not attacked by water.2. Referenced Documents2.1 ASTM Standards:2C20 Test Methods for Apparent Porosity, Water Absorp-tion, Apparent Specific Gravity, and Bulk Density ofBurned Refractory Brick and Shapes b
8、y Boiling WaterC 134 Test Methods for Size, Dimensional Measurements,and Bulk Density of Refractory Brick and InsulatingFirebrickE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Significance and Use3.1 Apparent porosity, water absorption, apparent s
9、pecificgravity, and bulk density are primary properties of refractoryshapes. These properties are widely used in the evaluation andcomparison of product quality and as part of the criteria forselection and use of refractory products in a variety ofindustrial applications. These test methods are used
10、 for deter-mining any or all of these properties and are particularly usefulfor testing hydratable products.3.2 These test methods are primary standard methods thatare suitable for use in quality control, research and develop-ment, establishing criteria for and evaluating compliance withspecificatio
11、ns, and providing data for design purposes.3.3 Fundamental assumptions inherent in these test methodsare:3.3.1 The test specimens conform to the requirements forsize, configuration, and original faces,3.3.2 The open pores of the test specimens are fully impreg-nated with liquid during the vacuum-pre
12、ssure treatment, and3.3.3 The blotting of the saturated test specimens is per-formed as specified in a consistent and uniform manner toavoid withdrawing liquid from the pores.3.3.4 Deviation from any of these assumptions adverselyaffects the test results.3.4 In laboratory studies involving castable
13、specimen, a biaswas noted between formed2X2X2in (50 X 50 X 50mm)and specimens quartered from larger 9 X 4.5 X 2.5in (228 X114 X 64mm) cast specimens. Additionally, an error in theapparent porosity determination was found on castables when-ever the specimens were heated to 1500F (816C) and thenexpose
14、d to water as a saturation media. The error was1These test methods are under the jurisdiction of ASTM Committee C08 onRefractories and are the direct responsibility of Subcommittee C08.03 on PhysicalProperties.Current edition approved June 1, 2006. Published June 2006. Originallyapproved in 1976. La
15、st previous edition approved in 2000 as C 830 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright A
16、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.attributed to reactivity of cement with water and subsequentre-hydration of cement phases. The higher the cement level ofthe castable, the greater the error noted. It was concluded thatan error in
17、porosity values could occur for refractory materialshaving a potential to form hydrated species with water. Testingunder the same conditions in kerosene produced results thatwere believed to be more accurate, but the data suggested thatthe kerosene might not have saturated the open pores of castspec
18、imen as readily as water. Supporting data were filed atASTM headquarters and can be obtained by requesting re-search report 1014.3.5 Certain precautions must be exercised in interpretingand using results from these test methods. All four propertyvalues are interrelated by at least two of the three b
19、ase datavalues generated during testing. Thus, an error in any base datavalue will cause an error in at least three of the property valuesfor a given test specimen. Certain of the properties, that is,apparent specific gravity and bulk density, are functions ofother factors such as product compositio
20、n, compositionalvariability within the same product, impervious porosity, andtotal porosity. Generalizations on or comparisons of propertyvalues should be judiciously made between like products testedby these test methods or with full recognition of potentiallyinherent differences between the produc
21、ts being compared orthe test method used.3.6 When a liquid other than water is used, such as types ofkerosene or mineral spirits, specific gravity must be known byeither determination or monitoring on a controlled basis.Specific gravity will change due to different grades of liquids,evaporation, or
22、contamination with dirt or foreign material.The test should not be run if the liquid becomes dirty, foamy,or changes color, because foreign particles can block pores andprevent impregnation of the sample.4. Test Specimens4.1 When testing 9-in. (228-mm) straight brick, use aquarter-brick specimen obt
23、ained by halving the brick along aplane parallel to the 9 by 212 or 3-in. (228 by 64 or 76-mm)face and along a plane parallel to the 412 by 212 or 3-in. (114by 64 or 76-mm) face. Four of the surfaces of the resultantquarter-brick specimen include part of the original moldedfaces.4.2 When testing oth
24、er refractory shapes, cut drill, or breakfrom each shape a specimen having a volume of approximately25 to 30 in.3(410 to 490 cm3). The specimen shall includeinterior and exterior portions of the shape.4.3 Remove all loosely adhering particles from each speci-men.5. Procedures5.1 Determination of Dry
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC83020002006E1STANDARDTESTMETHODSFORAPPARENTPOROSITYLIQUIDABSORPTIONAPPARENTSPECIFICGRAVITYANDBULKDENSITYOFREFRACTORYSHAPESBYVACUUMPRESSURE

链接地址:http://www.mydoc123.com/p-508461.html