ASTM C813-1990(2014) Standard Test Method for Hydrophobic Contamination on Glass by Contact Angle Measurement《使用接触角测量法对玻璃表面疏水污染物进行检测的标准试验方法》.pdf
《ASTM C813-1990(2014) Standard Test Method for Hydrophobic Contamination on Glass by Contact Angle Measurement《使用接触角测量法对玻璃表面疏水污染物进行检测的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C813-1990(2014) Standard Test Method for Hydrophobic Contamination on Glass by Contact Angle Measurement《使用接触角测量法对玻璃表面疏水污染物进行检测的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C813 90 (Reapproved 2014)Standard Test Method forHydrophobic Contamination on Glass by Contact AngleMeasurement1This standard is issued under the fixed designation C813; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the detection of hydrophobiccontamination on glass surfaces by means of contact an
3、glemeasurements. When properly conducted, the test will enabledetection of fractions of monomolecular layers of hydrophobicorganic contaminants. Very rough or porous surfaces maysignificantly decrease the sensitivity of the test.1.2 The values stated in SI units are to be regarded asstandard. No oth
4、er units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility o
5、f regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent Water3. Terminology3.1 Definitions:3.1.1 advancing anglethe largest angle observable when aliquid droplet is increased in size.3.1.2 hydrophilichaving a strong affinity for water; wet-tab
6、le.3.1.2.1 DiscussionHydrophilic surfaces exhibit zero con-tact angles.3.1.3 hydrophobichaving little affinity for water; nonwet-table.3.1.3.1 DiscussionHydrophobic surfaces exhibit contactangles appreciably greater than zero: generally greater than 45for the advancing angle.3.1.4 receding anglethe
7、smallest angle observable when aliquid droplet is decreased in size.3.1.5 sessile dropa drop of liquid sitting on the upper sideof a horizontal surface.3.1.5.1 DiscussionSee Fig. 1.4. Summary of Test Method4.1 The contact angle test is performed by depositingdroplets of permanganate-distilled water
8、or reagent water inaccordance with Specification D1193 on the surface to betested using a mounted hypodermic syringe, said dropletsbeing deposited in such a way, as described herein, as tomeasure the advancing contact angle. The measurements shallbe made by either of these two well-known methods: (1
9、)viewing the sessile drop through a comparator microscopefitted with a goniometer scale with direct measurement of theangle; or (2) photographing the sessile drop and measuring theangle with a protractor. The interpretation of the measurementsis based on the fact that organic contamination on surfac
10、esresults in contact angles appreciably higher than the near-zeroangles measured on clean surfaces or those contaminated byhydrophilic materials.5. Significance and Use5.1 The contact angle test is nondestructive and may be usedfor control and evaluation of processes for the removal ofhydrophobic co
11、ntaminants. The test may also be used for thedetection and control of hydrophobic contaminants in process-ing ambients. For this application, a surface free of hydropho-bic films is exposed to the ambient conditions and is subse-quently tested.6. Interferences6.1 Loss of sensitivity may result from
12、either of the follow-ing factors:6.1.1 The presence of hydrophilic substances on the surfaceto be tested, or in the water used for the test, or6.1.2 An unusually rough or porous surface.1This test method is under the jurisdiction of ASTM Committee C14 on Glassand Glass Products and is the direct res
13、ponsibility of Subcommittee C14.02 onChemical Properties and Analysis.Current edition approved Oct. 1, 2014. Published October 2014. Originallyapproved in 1975. Last previous edition approved in 2009 as C813 90 (2009).DOI: 10.1520/C0813-90R14.2For referenced ASTM standards, visit the ASTM website, w
14、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17. A
15、pparatus7.1 Low-Power Comparator Microscope (5 to 50),withgoniometer scale and light source for illumination of smalldrops.7.2 Camera, that can take photographs of the drop if thisalternative method is used.7.3 Protractor, to measure the angle if the alternativemethod is used.7.4 Hypodermic Syringe
16、or Micrometer Buret, in a fixedmount. The needle of the syringe or the buret tip should be BDgage 20 to 26 or equivalent and should have a square-cut tip.7.5 Movable Platen, on which to mount the specimen whenviewing the drop in profile.8. Reagents and Materials8.1 Purity of WaterEither Type II reag
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC81319902014STANDARDTESTMETHODFORHYDROPHOBICCONTAMINATIONONGLASSBYCONTACTANGLEMEASUREMENT 使用 接触角

链接地址:http://www.mydoc123.com/p-508431.html