《ASTM C813-1990(2004) Standard Test Method for Hydrophobic Contamination on Glass by Contact Angle Measurement《用接触角测量法测定玻璃表面上疏水污物量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C813-1990(2004) Standard Test Method for Hydrophobic Contamination on Glass by Contact Angle Measurement《用接触角测量法测定玻璃表面上疏水污物量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 813 90 (Reapproved 2004)Standard Test Method forHydrophobic Contamination on Glass by Contact AngleMeasurement1This standard is issued under the fixed designation C 813; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the detection of hydrophobiccontamination on glass surfaces by means of contact
3、 anglemeasurements. When properly conducted, the test will enabledetection of fractions of monomolecular layers of hydrophobicorganic contaminants. Very rough or porous surfaces maysignificantly decrease the sensitivity of the test.1.2 This standard does not purport to address all of thesafety conce
4、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent Water3.
5、 Terminology3.1 Definitions:3.1.1 advancing anglethe largest angle observable when aliquid droplet is increased in size.3.1.2 hydrophilichaving a strong affinity for water; wet-table.3.1.2.1 DiscussionHydrophilic surfaces exhibit zero con-tact angles.3.1.3 hydrophobichaving little affinity for water
6、; nonwet-table.3.1.3.1 DiscussionHydrophobic surfaces exhibit contactangles appreciably greater than zero: generally greater than 45for the advancing angle.3.1.4 receding anglethe smallest angle observable when aliquid droplet is decreased in size.3.1.5 sessile dropa drop of liquid sitting on the up
7、per sideof a horizontal surface.3.1.5.1 DiscussionSee Fig. 1.4. Summary of Test Method4.1 The contact angle test is performed by depositingdroplets of permanganate-distilled water or reagent water inaccordance with Specification D 1193 on the surface to betested using a mounted hypodermic syringe, s
8、aid dropletsbeing deposited in such a way, as described herein, as tomeasure the advancing contact angle. The measurements shallbe made by either of these two well-known methods: (1)viewing the sessile drop through a comparator microscopefitted with a goniometer scale with direct measurement of thea
9、ngle; or (2) photographing the sessile drop and measuring theangle with a protractor. The interpretation of the measurementsis based on the fact that organic contamination on surfacesresults in contact angles appreciably higher than the near-zeroangles measured on clean surfaces or those contaminate
10、d byhydrophilic materials.5. Significance and Use5.1 The contact angle test is nondestructive and may be usedfor control and evaluation of processes for the removal ofhydrophobic contaminants. The test may also be used for thedetection and control of hydrophobic contaminants in process-ing ambients.
11、 For this application, a surface free of hydropho-bic films is exposed to the ambient conditions and is subse-quently tested.6. Interferences6.1 Loss of sensitivity may result from either of the follow-ing factors:6.1.1 The presence of hydrophilic substances on the surfaceto be tested, or in the wat
12、er used for the test, or6.1.2 An unusually rough or porous surface.7. Apparatus7.1 Low-Power Comparator Microscope (53 to503), with goniometer scale and light source for illuminationof small drops.7.2 Camera, that can take photographs of the drop if thisalternative method is used.7.3 Protractor, to
13、measure the angle if the alternativemethod is used.1This test method is under the jurisdiction of ASTM Committee C14 on Glassand Glass Products and is the direct responsibility of Subcommittee C14.02 onChemical Properties and Analysis.Current edition approved Oct. 1, 2004. Published October 2004. Or
14、iginallyapproved in 1975. Last previous edition approved in 1999 as C 813 90 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary p
15、age onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.4 Hypodermic Syringe or Micrometer Buret, in a fixedmount. The needle of the syringe or the buret tip should be BDgage 20 to 26 or equivalent and should have a
16、square-cut tip.7.5 Movable Platen, on which to mount the specimen whenviewing the drop in profile.8. Reagents and Materials8.1 Purity of WaterEither Type II reagent water in accor-dance with Specification D 1193, or water distilled from a3-g/L potassium permanganate solution is usually satisfactory.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC81319902004STANDARDTESTMETHODFORHYDROPHOBICCONTAMINATIONONGLASSBYCONTACTANGLEMEASUREMENT 接触角 测量

链接地址:http://www.mydoc123.com/p-508429.html