ASTM C810-1990(2006) Standard Test Method for Nickel on Steel for Porcelain Enameling by X-Ray Emission Spectrometry《用X射线发射光谱法测定搪瓷用钢表面镍沉积量的标准试验方法》.pdf
《ASTM C810-1990(2006) Standard Test Method for Nickel on Steel for Porcelain Enameling by X-Ray Emission Spectrometry《用X射线发射光谱法测定搪瓷用钢表面镍沉积量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C810-1990(2006) Standard Test Method for Nickel on Steel for Porcelain Enameling by X-Ray Emission Spectrometry《用X射线发射光谱法测定搪瓷用钢表面镍沉积量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 810 90 (Reapproved 2006)Standard Test Method forNickel on Steel for Porcelain Enameling by X-Ray EmissionSpectrometry1This standard is issued under the fixed designation C 810; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the amountof nickel deposited on sheet steel during i
3、ts preparation forporcelain enameling. It is an X-ray emission method used fortesting sample panels or certain commercial parts.NOTE 1An alternative wet chemical method is Test Method C 715.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses a
4、re forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
5、 to use. For a specifichazards statement, see Section 7.2. Referenced Documents2.1 ASTM Standards:2C 715 Test Method for Nickel on Steel for Porcelain Enam-eling by Photometric Analysis3. Summary of Test Method3.1 Steel samples coated with a light nickel deposit areinserted in the sample position of
6、 an X-ray spectrometer. Thecount rate for nickel is measured and converted by means of acalibration curve to g/m2(g/f2).NOTE 21 m2= 10.75 ft2. Industry usage is typically in mixed units,grams per square foot. For example, 0.10 g/ft2equals a little more than 1g/m2.4. Significance and Use4.1 This test
7、 method is an accurate and rapid means formeasuring nickel deposits on steel sample plates and such partsthat can be fitted into the X-ray spectrometer. Its accuracyextends over a wide range of nickel deposits.5. Interferences5.1 There are no interferences from other elements present.However, low va
8、lues can result from absorption of the X raysby overlaying material. Grease on the sample or rust due tostorage in humid areas are examples of such material. Lowresults are also obtained on de-enameled samples because thenickel deposit is converted to a nickel iron alloy at enamelingtemperatures. Th
9、e presence of the iron in the alloy layerabsorbs some of the X radiation and accounts for the lowerresult.6. Apparatus6.1 Suitable X-Ray Emission Spectrometer complete with50-kV power supply goniometer, detector with pressure-regulated gas flow attachments, scaler-counter, lithium fluorideanalyzing
10、crystal, and 0.02 Soller slit collimator is required.3About a 1-in. (25.4-mm) diameter area of the sample isirradiated.6.2 Special Sample Holder (Fig. 1), to permit insertion of a2 by 2-in. (51 by 51-mm) flat corner of a large flat sample.Alternatively, the standard sample holder supplied with theeq
11、uipment may be used, but the sample must be cut to 1.5 by1.25 in. (38 by 32-mm).6.3 Steel Sheets with various amounts of nickel deposits arerequired for calibration and standardization.6.4 Nickel-Base Alloy Sample, such as 18-8 stainless steel,for routine calibration.7. Hazards7.1 Equipment should b
12、e periodically checked for radiationleaks to ensure against exposure to X radiation.8. Calibration and Standardization8.1 Prepare approximately 18 standard plates by cleaningand pickling 4 by 6 in. (102 by 152 mm) commercial1This test method is under the jurisdiction ofASTM Committee B08 on Metallic
13、and Inorganic Coatings and is the direct responsibility of Subcommittee B08.12 onMaterials for Porcelain Enamel and Ceramic-Metal Systems.Current edition approved April 1, 2006. Published May 2006. Originallyapproved in 1975. Last previous edition approved in 2000 as C 810 90 (2000).2For referenced
14、ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the following: (1) Philips Electronic Instruments, 750 S. Ful
15、tonAve., Mount Vernon, NY 10550; (2) Siemens Corp., Medical Industrial Div., 186Wood Ave., South, Iselin, NJ 08831; and (3) Diano Corp., X-ray Div., 2 LowellAve., Winchester, MA 01890.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC81019902006STANDARDTESTMETHODFORNICKELONSTEELFORPORCELAINENAMELINGBYXRAYEMISSIONSPECTROMETRY 射线

链接地址:http://www.mydoc123.com/p-508425.html