ASTM C728-2013 Standard Specification for Perlite Thermal Insulation Board《珍珠岩绝热板标准规格》.pdf
《ASTM C728-2013 Standard Specification for Perlite Thermal Insulation Board《珍珠岩绝热板标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C728-2013 Standard Specification for Perlite Thermal Insulation Board《珍珠岩绝热板标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C728 05 (Reapproved 2010)C728 13Standard Specification forPerlite Thermal Insulation Board1This standard is issued under the fixed designation C728; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers the composition and
3、physical properties for perlite thermal insulation board used principally abovestructural roof decks and as a base for built-up, modified, and elastomeric membrane roofing in building construction.1.2 The use of When adopted by an authority having jurisdiction, codes that address fire properties in
4、many applications regulatethe use of the thermal insulation materials covered by this specification may be regulated by building codes or other agencies thataddress fire performance, or both. The fire performance of the material should be addressed through standard fire test methodsestablished by th
5、e appropriate governing documents.specification. Fire properties are controlled by job, project, or otherspecifications where codes or government regulations do not apply.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconvers
6、ions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices
7、 and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 The following standards, of the issue in effect on the date of material purchase, form a part of this specification to the extentspecified herein:2.2 ASTM Standards:2C165 Test Method for Measuring Compr
8、essive Properties of Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of theGuarded-Hot-Plate ApparatusC203 Test Methods for Breaking Load and Flexural Properties of Block-Type Ther
9、mal InsulationC209 Test Methods for Cellulosic Fiber Insulating BoardC390 Practice for Sampling and Acceptance of Thermal Insulation LotsC518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter ApparatusC1289 Specification for Faced Rigid Cellular Polyisocyan
10、urate Thermal Insulation BoardE84 Test Method for Surface Burning Characteristics of Building Materials3. Terminology3.1 For complete descriptions of terms used in this specification, refer to Terminology C168.4. Classification4.1 Perlite thermal insulation board is classified as follows:4.1.1 Type
11、1, Roof Insulation BoardA perlite based roof insulation cover board.1 This specification is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.22 on Organic andNonhomogeneous Inorganic Thermal Insulations.Current edition approved M
12、arch 1, 2010May 1, 2013. Published March 2010May 2013. Originally approved in 1972. Last previous edition approved in 20052010 asC728C72805(2010).05. DOI: 10.1520/C0728-05R10.10.1520/C0728-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serv
13、iceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version.
14、Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 1
15、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.2 Type 1, Roof Insulation 2, Roof Cover or Recover BoardTheThis 12 in. (13 mm) thick version of this product is availableonly is used primarily as a field-applied cover board over other roof insulations or in rero
16、ofing applications. The product is alsoavailable to manufacturers of laminated rigid foam products as specified in Specification C1289., Type III.4.1.3 Type 2, Roof Cover/Recover 3, Roof Cover or Recover BoardThis is used primarily as a field-applied cover boardAperlite based cover board that is fie
17、ld applied over other roof insulations or in reroofing applications.re-roofing and recoverapplications. The product is also available to manufacturers of laminated rigid foam products as specified in Specification C1289,Type III.5. Ordering Information5.1 Orders shall at least include the following
18、information:5.1.1 Title and designation Specification C728.5.1.2 Product name, nominal thickness and dimensions.5.1.3 Quantity of material ordered.5.1.4 Manufacturers name, address, and telephone number.6. Materials and Manufacture6.1 CompositionThe basic material of the insulation board shall be pe
19、rlite expanded by the application of heat to form glassy,cellular aggregates. The insulation and cover board shall be composed of expanded perlite and fibers formed into rigid, flat,rectangular units with a suitable sizing material incorporated in the product. It may have A facing or coating is pote
20、ntially presenton one or both surfaces a facing or coating to prevent excessive hot bitumen strike-in or adhesive absorption during roofinginstallation.6.2 LaminationThe finished board may be is either single-ply or multiple-ply. When multiple-ply boards are supplied, asuitable adhesive shall be use
21、d to join the plies.7. Physical Properties7.1 Thermal ResistancePerlite thermal insulation boards and cover shall conform to the following thermal resistances:Nominal Thicknessin. (mm)Thermal Resistance,Fhft2/btu (Km2/W)Type 1 Type 212 (13) 1.4 (0.25) 1.3 (0.23)34 (19) 2.0 (0.35) .1 (25) 2.7 (0.48)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC7282013STANDARDSPECIFICATIONFORPERLITETHERMALINSULATIONBOARD 珍珠岩 绝热 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-508142.html