《ASTM C727-2001(2007)e1 Standard Practice for Installation and Use of Reflective Insulation in Building Constructions《建筑结构中反射隔热的装置及应用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C727-2001(2007)e1 Standard Practice for Installation and Use of Reflective Insulation in Building Constructions《建筑结构中反射隔热的装置及应用标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 727 01 (Reapproved 2007)e1Standard Practice forInstallation and Use of Reflective Insulation in BuildingConstructions1This standard is issued under the fixed designation C 727; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTESections 2, 3.2.5, 5.1, 7.2, and footnotes 4 and 5 were editorially corrected in April 2007.1. Scope1.
3、1 This practice has been prepared for use by the designer,specifier, and installer of reflective insulation for use inbuilding construction. The scope is limited to recommenda-tions relative to the use and installation of thermal insulationconsisting of one or more surfaces, having an emittance of 0
4、.1or less such as metallic foil or metallic deposits unmounted ormounted on substrates and facing enclosed air spaces. Thereflective insulation covered by this practice must meet therequirements of Specification C 1224.1.2 This practice covers the installation process from pre-installation inspectio
5、n through post-installation procedure. Itdoes not cover the production of the insulation materials.1.3 This practice is not intended to replace the manufactur-ers installation instructions, but shall be used in conjunctionwith such instructions. This practice is not intended to super-cede local, sta
6、te, or federal codes.1.4 This practice assumes that the installer possesses a goodworking knowledge of the applicable codes and regulations,safety practices, tools, equipment, and methods necessary forthe installation of thermal insulation materials. It also assumesthat the installer understands the
7、 fundamentals of constructionthat affect the installation of insulation.1.5 The values given in inch-pound units are to be regardedas standard. The SI units in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use
8、. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationC 1224 Specification for Ref
9、lective Insulation for BuildingApplicationsE 96/E 96M Test Methods for Water Vapor Transmission ofMaterials2.2 NFPA Standards:NFPA 31 Standard for the Installation of Oil BurningEquipment3NFPA 54 National Fuel Gas Code3NFPA 211 Standard for Chimneys, Fireplaces, and Vents32.3 Code of Federal Regulat
10、ions:16 CFR 460 Federal Trade Commission Trade RegulationRule: Labeling and Advertising of Home Insulation43. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice refer to Terminology C 1683.2 Descriptions of Terms Specific to This Standard:3.2.1 applicatorthe person or persons
11、who apply thermalinsulation materials in buildings whether or not such person orpersons have contracted with the owner to perform the work.3.2.2 conditioned spaceany space in a building that isserved by a heating or cooling system.3.2.3 ownerthe person, partnership, corporation, agency,or other enti
12、ty owning the building to be insulated whethersuch ownership is by virtue of deed, contract, or any otherinstrument for acquiring legal title under the laws of the statein which the building is located.1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the dir
13、ect responsibility of Subcommittee C16.21 on ReflectiveInsulation.Current edition approved March 1, 2007. Published April 2007. Originallyapproved in 1972. Last previous edition approved 2001 as C 727 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Se
14、rvice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.4Federal Register, Vol 70, No. 103
15、. Available from Department of Housing andUrban Development, 451 7th St. N.W., Washington, D.C. 20410.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.4 reflective insulation systemthermal insulation con-sisting of one or more low
16、 emittance surfaces, bounding one ormore enclosed air spaces.3.2.5 vapor retarderany material (membrane or paint)that has a water vapor permeance (perm) rating of 57 ng/(Pasm2) (1 perm) or less, in accordance with Test MethodsE 96/E 96M, using the desiccant method.4. Significance and Use4.1 This pra
17、ctice recognizes that effectiveness, safety, anddurability of reflective insulation depends not only on thequality of the insulating materials, but also on their properinstallation.4.2 Improper installation of insulation can reduce its ther-mal effectiveness, cause fire risks and other unsafe condit
18、ions,and promote deterioration of the structure in which it isinstalled. Specific hazards that can result from improperinstallation include fires caused by (1) heat build-up in recessedlighting fixtures, (2) deterioration or failure of electrical wiringcomponents, and heat build-up resulting from ov
19、ercurrentprotection devices incorrectly matched to wiring; or (3) dete-rioration in wood structures and paint failure due to moistureaccumulation.4.3 This practice provides recommendations for the instal-lation of reflective insulation in a safe and effective manner.Actual conditions in existing bui
20、ldings may vary greatly and insome cases additional care should be taken to ensure safe andeffective installation.4.4 This practice presents requirements that are general innature and considered practical. They are not intended asspecific recommendations. The user should consult manufac-turer for re
21、commended applications.5. Safety Precautions5.1 The applicator shall wear proper clothing and equip-ment. Protective clothing, gloves, and eye protection should beworn if there is any doubt about the effects of the insulation.6. Pre-Installation Inspection and Preparation6.1 In areas where insulatio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC72720012007E1STANDARDPRACTICEFORINSTALLATIONANDUSEOFREFLECTIVEINSULATIONINBUILDINGCONSTRUCTIONS

链接地址:http://www.mydoc123.com/p-508138.html