ASTM C67-2014 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile《砖和结构粘土瓦的取样和试验的标准试验方法》.pdf
《ASTM C67-2014 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile《砖和结构粘土瓦的取样和试验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C67-2014 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile《砖和结构粘土瓦的取样和试验的标准试验方法》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C67 13aC67 14 American Association State Highway and TransportationOfficials StandardAASHTO No.: T 32-70Standard Test Methods forSampling and Testing Brick and Structural Clay Tile1This standard is issued under the fixed designation C67; the number immediately following the designation
2、indicates the year of originaladoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of
3、 the U.S. Department of Defense.1. Scope*1.1 These test methods cover procedures for the sampling and testing of brick and structural clay tile. Although not necessarilyapplicable to all types of units, tests include modulus of rupture, compressive strength, absorption, saturation coefficient, effec
4、t offreezing and thawing, efflorescence, initial rate of absorption and determination of weight, size, warpage, length change, and voidarea. (Additional methods of test pertinent to ceramic glazed facing tile are included in Specification C126.)1.2 The text of this standard references notes and foot
5、notes which provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.NOTE 1The testing laboratory performing this test method should be evaluated in accordance with Practice C1093.1.3 The values stated in i
6、nch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It
7、 is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C126 Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, an
8、d Solid Masonry UnitsC150 Specification for Portland CementC1093 Practice for Accreditation of Testing Agencies for MasonryC1232 Terminology of MasonryE4 Practices for Force Verification of Testing MachinesE6 Terminology Relating to Methods of Mechanical TestingE177 Practice for Use of the Terms Pre
9、cision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 DefinitionsFor definitions relating to sampling and testing brick, refer to Terminology E6 and Terminology C1232.4. Sampling4.1 Selection and Prepara
10、tion of Test SpecimensFor the purpose of these tests, full-size brick, tile, or solid masonry units shallbe selected by the purchaser or by the purchasers authorized representative. Specimens shall be representative of the lot of unitsfrom which they are selected and shall include specimens represen
11、tative of the complete range of colors, textures, and sizes.Specimens shall be free of or brushed to remove dirt, mud, mortar, or other foreign materials unassociated with the manufacturingprocess. Brushes used to remove foreign material shall have bristles of plastic (polymer) or horsehair. Wire br
12、ushes shall not be1 These test methods are under the jurisdiction of Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.02 on Brick andStructural Clay Tile.Current edition approved Dec. 1, 2013July 1, 2014. Published December 2013September 2014. Original
13、ly approved in 1937. Last previous edition approved in 2013 asC67 13.C67 13a. DOI: 10.1520/C0067-13A.10.1520/C0067-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to
14、 the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes
15、 accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr H
16、arbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1used for preparing specimens for testing. Specimens exhibiting foreign material that is not removed by brushing shall be discardedto ensure that damaged or contaminated specimens are not tested.4.2 Number of Specimens:4.2.1 Br
17、ickFor the modulus of rupture, compressive strength, abrasion resistance, and absorption determinations, at least tenindividual brick shall be selected for lots of 1 000 000 brick or fraction thereof. For larger lots, five additional specimens shall beselected from each additional 500 000 brick or f
18、raction thereof. Additional specimens are taken at the discretion of the purchaser.4.2.2 Structural Clay TileFor the weight determination and for compressive strength and absorption tests, at least five tile shallbe selected from each lot of 250 tons (226.8 Mg) or fraction thereof. For larger lots,
19、five additional specimens shall be tested foreach 500 tons (453.6 Mg) or fraction thereof. In no case shall less than five tile be taken. Additional specimens are taken at thediscretion of the purchaser.4.3 IdentificationEach specimen shall be marked so that it is identifiable at any time. Markings
20、shall cover not more than 5 %of the superficial area of the specimen.5. Specimen Preparation5.1 Drying and Cooling:5.1.1 DryingDry the test specimens in a ventilated oven at 230 to 239F (110 to 115C) for not less than 24 h and until twosuccessive weighings at intervals of 2 h show an increment of lo
21、ss not greater than 0.2 % of the last previously determined weightof the specimen.5.1.2 CoolingAfter drying, cool the specimens in a drying room maintained at a temperature of 75 6 15F (24 6 8C), witha relative humidity between 30 and 70 %. Store the units free from drafts, unstacked, with separate
22、placement, for a period of atleast 4 h and until the surface temperature is within 5F (2.8C) of the drying room temperature. Do not use specimens noticeablywarm to the touch for any test requiring dry units. The specimens shall be stored in the drying room with the required temperatureand humidity m
23、aintained until tested.5.1.2.1 An alternative method of cooling the specimens to approximate room temperature is permitted as follows: Store units,unstacked, with separate placement, in a ventilated room maintained at a temperature of 75 6 15F (24 6 8C), with a relativehumidity between 30 and 70 % f
24、or a period of 4 h and until the surface temperature is within 5F (2.8C) of the ventilated roomtemperature, with a current of air from an electric fan passing over them for a period of at least 2 hours. The specimens shall bestored in the ventilated room with the required temperature and humidity ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC672014STANDARDTESTMETHODSFORSAMPLINGANDTESTINGBRICKANDSTRUCTURALCLAYTILE 结构 粘土 取样 试验 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-507977.html