ASTM C653-1997(2007) Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation《建筑物隔热用低密度矿物纤维毡阻热系数的测定的标准指南》.pdf
《ASTM C653-1997(2007) Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation《建筑物隔热用低密度矿物纤维毡阻热系数的测定的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM C653-1997(2007) Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation《建筑物隔热用低密度矿物纤维毡阻热系数的测定的标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 653 97 (Reapproved 2007)Standard Guide forDetermination of the Thermal Resistance of Low-DensityBlanket-Type Mineral Fiber Insulation1This standard is issued under the fixed designation C 653; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes the calculation and interpolation ofa thermal resistance va
3、lue for low-density blanket-type insula-tion material at a particular density and thickness having beenselected as representative of the product. It requires measuredvalues of this average density and thickness, as well asapparent thermal conductivity values determined by either TestMethod C 177, C
4、518, or C 1114.1.2 This guide applies to a density range for mineral-fibermaterial of roughly 6.4 to 48 kg/m3(0.4 to 3.0 lb/ft3). It isprimarily intended to apply to low-density, mineral-fiber massinsulation batts and blankets, exclusive of any membranefacings. Apparent thermal conductivity data for
5、 these productsare commonly reported at a mean temperature of 23.9C (75F)and a hot-to-cold plate temperature difference of 27.8C (50F)or 22.2C (40F).1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this s
6、tandard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsC 168 Terminology Relating to Thermal Ins
7、ulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 1045 Practice for Calculating Thermal Transmiss
8、ionProperties Under Steady-State ConditionsC 1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater Apparatus3. Terminology3.1 DefinitionsFor definitions used in this guide, refer toTerminology C 168.3.2 Definitions of Terms Specific to This Standard:3.2.1 appar
9、ent thermal conductivity, lthe ratio of thespecimen thickness to thermal resistance of the specimen. It iscalculated as follows:l5L/R W/mk! or Btu in./ft2hF! (1)3.2.1.1 DiscussionFor this type of material an expressionfor the apparent thermal conductivity as a function of densityis:l5a 1 bD 1 c/D (2
10、)where a, b, c = parameters characteristic of a product, and related tothe conductivity of the gas, the conductivity of the solid and theconductivity due to radiation.(1)33.3 Symbols:R = thermal resistance, (m2K/W) or (hft2F/Btu)l = apparent thermal conductivity, (W/mK) or (Btuin/hft2F)Q/A = heat fl
11、ow per unit area, (W/m2) or (Btu/hft2)D = bulk density of a specimen, (kg/m3) or (lb/ft3)L = measured specimen thickness, (m) or (in.)T = apparatus plate temperature, (K) or (F)L8 = specimen thickness if the sample from which thespecimen is selected does not recover to labelthickness, (m) or (in.)s
12、= estimate of the standard deviation for a set of datapointsD = apparatus systematic errorC = overall uncertainty in a measured R-value3.3.1 Subscripts:1This guide is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.30 on ThermalM
13、easurement.Current edition approved March 1, 2007. Published April 2007. Originallyapproved in 1970. Last previous edition approved in 2002 as C 653 97(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of A
14、STMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to a list of references at the end ofthis standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United S
15、tates.av= signifies average of a lotH= refers to hot surfaceC= refers to cold surfaceT= refers to test specimenN= refers to nominal property for the product, as shownon the product labeli= refers to a set of data pointss= refers to a particular specimen4. Significance and Use4.1 This guide provides
16、a method to determine the thermalperformance of low-density blanket-type insulation. It may beused for the purposes of quality assurance, certification, orresearch.4.2 The thermal resistance of low-density insulation de-pends significantly on the density, the thickness, and thermalconductivity. Typi
17、cal low-density, mineral-fiber insulation forbuildings may vary in density from one specimen to the next.4.3 Thermal tests are time-consuming in comparison withdensity and thickness measurements. Low-density insulationmaterial is produced in large quantities. A typical lot would bea truckload or the
18、 amount necessary to insulate a house.4.4 The relatively low unit cost of this product and therelatively high cost of thermal resistance testing makes itcost-effective to test only a small percentage of the productarea. It is recommended that there be a determination of thedensity that is representa
19、tive of a lot by the measurement of theaverage density of a statistically representative sampling.4.5 Afewer number of thermal measurements are then madeto determine the apparent thermal conductivity at the previ-ously determined representative density. The essential signifi-cance of this guide is t
20、hat a large lot of variable material is bestcharacterized by: (a) determining the representative density,and by (b) determining the thermal property at this represen-tative density with a small number of thermal measurements.4.6 Building insulation products are commonly manufac-tured in thicknesses
21、ranging from 19 to 330 mm (0.75 to 13 in.)inclusive. Experimental work has verified that there is adependence of lappon thickness for some low density materi-als.4.7 The upper limit of test thickness for specimens evalu-ated using Test Methods C 177, C 518, and C 1114 is estab-lished based upon the
22、apparatus design, overall dimensions,expected thermal resistivity level and desired target accuracy.The testing organization is responsible for applying theserestrictions when evaluating a product to ensure that the resultsmeet applicable product labels and any existing regulatoryrequirements.(2)4.8
23、 Extrapolation of the apparent thermal conductivity orthe thermal resistance beyond the ranges of thickness ordensity of products tested is not valid.5. Sampling5.1 For low-density mineral-fiber insulation, a lot samplesize of 75 to 150 ft2is recommended to determine the averagedensity, Dav. Density
24、 is determined by using Test MethodC 167; take care to avoid the use of damaged material.5.2 In order to account for the variation in l-value due toproduct density variability, measure a minimum of three “lversus D” data points on three different samples. This repre-sents nine data points for the “l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC65319972007STANDARDGUIDEFORDETERMINATIONOFTHETHERMALRESISTANCEOFLOWDENSITYBLANKETTYPEMINERALFIBERINSULATION

链接地址:http://www.mydoc123.com/p-507900.html